A CLUE for better assessment of donor lungs: Novel technique in clinical ex vivo lung perfusion

被引:18
|
作者
Ayyat, Kamal S. [1 ,2 ,3 ]
Okamoto, Toshihiro [1 ,2 ,4 ]
Niikawa, Hiromichi [1 ,2 ]
Sakanoue, Ichiro [1 ,2 ]
Dugar, Siddharth [5 ]
Latifi, Samir Q. [6 ,7 ]
Lebovitz, Daniel J. [7 ,8 ]
Moghekar, Ajit [5 ]
McCurry, Kenneth R. [1 ,2 ,4 ]
机构
[1] Cleveland Clin, Lerner Res Inst, Dept Inflammat & Immunol, Cleveland, OH 44106 USA
[2] Cleveland Clin, Dept Thorac & Cardiovasc Surg, Cleveland, OH 44106 USA
[3] Zagazig Univ, Dept Cardiothorac Surg, Fac Med, Zagazig, Egypt
[4] Cleveland Clin, Transplant Ctr, Cleveland, OH 44106 USA
[5] Cleveland Clin, Resp Inst, Cleveland, OH 44106 USA
[6] Cleveland Clin, Dept Pediat Crit Care, Cleveland, OH 44106 USA
[7] Lifebanc, Cleveland, OH USA
[8] Akron Childrens Hosp, Dept Crit Care Med, Akron, OH 44308 USA
来源
JOURNAL OF HEART AND LUNG TRANSPLANTATION | 2020年 / 39卷 / 11期
关键词
lung transplantation; pulmonary edema; marginal donor lungs; ex vivo lung perfusion; extravascular lung water; lung ultrasound; PRIMARY GRAFT DYSFUNCTION; NITRIC-OXIDE; WATER; INJURY;
D O I
10.1016/j.healun.2020.07.013
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
BACKGROUND: The direCt Lung Ultrasound Evaluation (CLUE) technique was proven to be an accurate method for monitoring extravascular lung water in donor lungs during ex vivo lung perfusion (EVLP) in an experimental model. The aim of this study was to examine the application of CLUE in the clinical setting. METHODS: Lungs were evaluated using acellular EVLP protocol. Ultrasound images were obtained directly from the lung surface. Images were graded according to the percentage of B-lines seen on ultrasound. CLUE scores were calculated at the beginning and end of EVLP for the whole lung, each side, and lobe based on the number (No.) of images in each grade and the total No. of images taken and evaluated retrospectively. RESULTS: A total of 23 EVLP cases were performed resulting in 13 lung transplants (LTxs) with no hospital mortality. Primary graft dysfunction (PGD) occurred in only 1 recipient (PGD3, no PGD2). Significant differences were found between suitable and non-suitable lungs in CLUE scores (1.03 vs 1.85, p < 0.001), unlike the partial pressure of oxygen/fraction of inspired oxygen ratio. CLUE had the highest area under the receiver operating characteristic curve (0.98) compared with other evaluation parameters. The initial CLUE score of standard donor lungs was significantly better than marginal lungs. The final CLUE score in proned lungs showed improvement when compared with initial CLUE score, especially in the upper lobes. CONCLUSIONS: The CLUE technique shows the highest accuracy in evaluating donor lungs for LTx suitability compared with other parameters used in EVLP. CLUE can optimize the outcomes of LTx by guiding the decision making through the whole process of clinical EVLP. (C) Published by Elsevier Inc. on behalf of International Society for Heart and Lung Transplantation.
引用
收藏
页码:1220 / 1227
页数:8
相关论文
共 50 条
  • [1] A CLUE for Better Assessment of Donor Lungs: Novel Technique in Clinical Ex-Vivo Lung Perfusion
    Ayyat, K. S.
    Okamoto, T.
    Niikawa, H.
    Sakanoue, I.
    Dugar, S.
    Latifi, S. Q.
    Lebovitz, D. J.
    Moghekar, A.
    McCurry, K. R.
    JOURNAL OF HEART AND LUNG TRANSPLANTATION, 2020, 39 (04): : S112 - S112
  • [2] Normothermic Ex Vivo Lung Perfusion as an Assessment of Marginal Donor Lungs - The NOVEL Lung Trial
    Sanchez, P. G.
    Davis, R. D.
    D'ovidio, F.
    Weyan, M. J.
    Camp, P. C.
    Cantu, E., III
    Griffith, B. P.
    JOURNAL OF HEART AND LUNG TRANSPLANTATION, 2013, 32 (04): : S16 - S17
  • [3] The Complete Score for Assessment of Donor Lungs: A Comprehensive Evaluation System in Clinical Ex-Vivo Lung Perfusion
    Ayyat, K. S.
    Okamoto, T.
    Sakanoue, I.
    Elgharably, H.
    Niikawa, H.
    Said, S. A.
    Yun, J. J.
    Nowacki, A. S.
    McCurry, K. R.
    JOURNAL OF HEART AND LUNG TRANSPLANTATION, 2021, 40 (04): : S66 - S66
  • [4] Normothermic Ex Vivo Lung Perfusion (Novel) as an Assessment of Extended Criteria Donor Lungs: A Prospective Multi-Center Clinical Trial
    Sanchez, P. G.
    Chan, E. G.
    Davis, R. D.
    Hartwig, M.
    Machuca, T.
    Whitson, B.
    Daneshmand, M.
    Ovidio, F. D.
    DCunha, J.
    Weyant, M.
    Jessen, M.
    Bermudez, C.
    Mulligan, M.
    Wozniak, T.
    Lynch, W.
    Nemeh, H.
    Caldeira, C.
    Song, T.
    Kreisel, D.
    Camp, P.
    Ramzy, D.
    Griffith, B.
    Cantu, E.
    JOURNAL OF HEART AND LUNG TRANSPLANTATION, 2022, 41 (04): : S40 - S41
  • [5] Successful lung transplant cases with ex vivo lung perfusion assessment of extended criteria donor lungs
    Nakajima, Daisuke
    Nagata, Shunichi
    Kayawake, Hidenao
    Tanaka, Satona
    Yamada, Yoshito
    Yutaka, Yojiro
    Ohsumi, Akihiro
    Hamaji, Masatsugu
    Chen-Yoshikawa, Toyofumi F.
    Date, Hiroshi
    GENERAL THORACIC AND CARDIOVASCULAR SURGERY, 2022, 70 (04) : 406 - 412
  • [6] Successful lung transplant cases with ex vivo lung perfusion assessment of extended criteria donor lungs
    Daisuke Nakajima
    Shunichi Nagata
    Hidenao Kayawake
    Satona Tanaka
    Yoshito Yamada
    Yojiro Yutaka
    Akihiro Ohsumi
    Masatsugu Hamaji
    Toyofumi F. Chen-Yoshikawa
    Hiroshi Date
    General Thoracic and Cardiovascular Surgery, 2022, 70 : 406 - 412
  • [7] Donor Lungs With Pulmonary Embolism Evaluated with Ex Vivo Lung Perfusion
    Brown, Chase R.
    Brozzi, Nicolas A.
    Vakil, Nakul
    Shafii, Alexis E.
    Murthy, Sudish C.
    Pettersson, Gosta B.
    Mason, David P.
    ASAIO JOURNAL, 2012, 58 (04) : 432 - 434
  • [8] The Conversional Efficacy of Ex Vivo Lung Perfusion and Clinical Outcomes in Patients Undergoing Transplantation of Donor Lungs by Ex Vivo Lung Perfusion: A Meta-Analysis
    Luo, Qiuping
    Zhu, Linhai
    Wang, Yiqing
    Wang, Luming
    Lv, Wang
    Hu, Jian
    ANNALS OF TRANSPLANTATION, 2019, 24 : 647 - 660
  • [9] Membraneless Perfusion - A Novel Technique for Ex Vivo Lung Perfusion
    Garza, G.
    Wang, A.
    Yune, J.
    Zhang, Y.
    Montagne, J.
    Siebiger, G. Loesch
    Yamanashi, K.
    Oliveira, P.
    Del Sorbo, L.
    Liu, M.
    Keshavjee, S.
    Cypel, M.
    JOURNAL OF HEART AND LUNG TRANSPLANTATION, 2024, 43 (04): : S79 - S79
  • [10] Important Implication in Evaluation of Donor Lungs in Single Lung Ex Vivo Lung Perfusion
    Niikawa, H.
    Okamoto, T.
    Ayyat, K.
    Itoda, Y.
    McCurry, K. R.
    JOURNAL OF HEART AND LUNG TRANSPLANTATION, 2017, 36 (04): : S54 - S55