What Do We Know About Taper Corrosion in Total Hip Arthroplasty?

被引:81
作者
Jacobs, J. J. [1 ]
Cooper, H. J. [2 ]
Urban, R. M. [1 ]
Wixson, R. L. [3 ]
Della Valle, C. J. [1 ]
机构
[1] Rush Univ, Med Ctr, Dept Orthoped Surg, Chicago, IL 60612 USA
[2] Lenox Hill Hosp, Dept Orthopaed Surg, New York, NY 10021 USA
[3] Northwestern Univ, Med Ctr, Dept Orthopaed Surg, Chicago, IL 60611 USA
关键词
hip replacement; corrosion; modular necks; modularity; adverse local tissue reaction; metal ion; ON-METAL BEARINGS; NECK;
D O I
10.1016/j.arth.2014.02.014
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Mechanically assisted crevice corrosion (MACC) at metal/metal modular junctions in which at least one of the components is fabricated from cobalt-chromium alloy, has reemerged as a potential clinically significant complication in total hip arthroplasty. The clinical manifestation of MACC may include the development of an adverse local tissue reaction (ALTR), similar to what has been described in association with metal-on-metal bearing total hip and resurfacing arthroplasty. The clinical presentation of MACC-associated ALTRs may include pain and possibly late recurrent dislocations. Abnormal metal artifact reduction sequence magnetic resonance images and elevated serum metal levels (cobalt elevations out of proportion to chromium elevations) can be helpful in the diagnosis of these MACC-associated ALTRs. (C) 2014 Elsevier Inc. All rights reserved.
引用
收藏
页码:668 / 669
页数:2
相关论文
共 14 条
  • [1] COLLIER JP, 1991, CLIN ORTHOP RELAT R, P305
  • [2] Adverse Local Tissue Reaction Arising from Corrosion at the Femoral Neck-Body Junction in a Dual-Taper Stem with a Cobalt-Chromium Modular Neck
    Cooper, H. John
    Urban, Robert M.
    Wixson, Richard L.
    Meneghini, R. Michael
    Jacobs, Joshua J.
    [J]. JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2013, 95A (10) : 865 - 872
  • [3] Corrosion at the Head-Neck Taper as a Cause for Adverse Local Tissue Reactions After Total Hip Arthroplasty
    Cooper, H. John
    Della Valle, Craig J.
    Berger, Richard A.
    Tetreault, Matthew
    Paprosky, Wayne G.
    Sporer, Scott M.
    Jacobs, Joshua J.
    [J]. JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2012, 94A (18) : 1655 - 1661
  • [4] Metal Ion Measurement as a Diagnostic Tool to Identify Problems with Metal-on-Metal Hip Resurfacing
    de Smet, K.
    de Haan, R.
    Calistri, A.
    Campbell, P. A.
    Ebramzadeh, E.
    Pattyn, C.
    Gill, H. S.
    [J]. JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2008, 90A : 202 - 208
  • [5] The John Charnley Award Metal-on-Metal Hip Resurfacing versus Large-diameter Head Metal-on-Metal Total Hip Arthroplasty A Randomized Clinical Trial
    Garbuz, Donald S.
    Tanzer, Michael
    Greidanus, Nelson V.
    Masri, Bassam A.
    Duncan, Clive P.
    [J]. CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2010, 468 (02) : 318 - 325
  • [6] IN-VIVO CORROSION OF MODULAR HIP-PROSTHESIS COMPONENTS IN MIXED AND SIMILAR METAL COMBINATIONS - THE EFFECT OF CREVICE, STRESS, MOTION, AND ALLOY COUPLING
    GILBERT, JL
    BUCKLEY, CA
    JACOBS, JJ
    [J]. JOURNAL OF BIOMEDICAL MATERIALS RESEARCH, 1993, 27 (12): : 1533 - 1544
  • [7] "Asymptomatic" Pseudotumors After Metal-on-Metal Hip Resurfacing Arthroplasty
    Kwon, Young-Min
    Ostlere, Simon J.
    McLardy-Smith, Peter
    Athanasou, Nicholas A.
    Gill, Harinderjit S.
    Murray, David W.
    [J]. JOURNAL OF ARTHROPLASTY, 2011, 26 (04) : 511 - 518
  • [8] Lymphocyte Proliferation Responses in Patients with Pseudotumors following Metal-on-Metal Hip Resurfacing Arthroplasty
    Kwon, Young-Min
    Thomas, Peter
    Summer, Burkhard
    Pandit, Hemant
    Taylor, Adrian
    Beard, David
    Murray, David W.
    Gill, Harinderjit S.
    [J]. JOURNAL OF ORTHOPAEDIC RESEARCH, 2010, 28 (04) : 444 - 450
  • [9] Taper junction failure in large-diameter metal-on-metal bearings
    Langton, D. J.
    Sidaginamale, R.
    Lord, J. K.
    Nargol, A. V. F.
    Joyce, T. J.
    [J]. BONE & JOINT RESEARCH, 2012, 1 (04): : 56 - 63
  • [10] Early failure of metal-on-metal bearings in hip resurfacing and large-diameter total hip replacement A CONSEQUENCE OF EXCESS WEAR
    Langton, D. J.
    Jameson, S. S.
    Joyce, T. J.
    Hallab, N. J.
    Natu, S.
    Nargol, A. V. F.
    [J]. JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 2010, 92B (01): : 38 - 46