Evaluation of the retention characteristics of various stud attachment systems for implant retained overdenture

被引:6
作者
Gonuldas, Fehmi [1 ]
Tokar, Emre [2 ]
Ozturk, Caner [3 ]
机构
[1] Ankara Univ, Fac Dent, Dept Prosthodont, Ankara, Turkey
[2] Gazi Univ, Fac Dent, Dept Prosthodont, AD 06490,Emek Mah 8 Cad 1 Sk 4, Ankara, Turkey
[3] Mustafa Kemal Univ, Fac Dent, Dept Prosthodont, Antakya, Turkey
关键词
overdenture; implant-supported dental prosthesis; denture precision attachment; retention; LOAD-TRANSFER CHARACTERISTICS; DENTURE-BEARING AREA; MANDIBULAR OVERDENTURES; IN-VITRO; SUPPORTED OVERDENTURES; INTERIMPLANT DISTANCE; SELECTION; LOCATOR; BALL; CONFIGURATIONS;
D O I
10.5277/ABB-01263-2018-02
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
The purpose of the study was to analyze and compare retention characteristics of different stud attachments including a standard and two low profile attachments on two implant embedded test models. Methods: Three different stud attachment systems (Ball attachment and two different low profile stud attachments - Equator and Locator) were used in this study. Two dental implants were placed vertically into a custom-made acrylic resin block within a 22 mm distance. Strong and soft nylon inserts of each attachment system were tested using cyclic dislodgement test for 24 months simulation. Maximum forces during the test were recorded and 10 consecutive data at baseline, 1st to 24th months were analyzed. Repeated measures ANOVA and post-hoc Tukey' s test (p < 0.05) were used for statistical analysis. Results: Retentive forces of the tested attachments varied from 30.7 to 93.75 N at the baseline. The highest initial mean retention (93.75 N) was observed in Group LC (locator attachment with clear nylon inserts) and the lowest initial mean retention (30.7 N) was detected in both Group BO (ball attachment with orange nylon inserts) and Group EY (equator with yellow nylon inserts). After the 24 months simulation, locator groups illustrated more light retention than other tested attachment systems. Conclusions: All tested attachment systems showed a significant decrease in retention value at the end of the simulated period. The locator attachment had significantly higher reduction in retention values compared to other low profile stud attachment equator and ball attachment.
引用
收藏
页码:135 / 141
页数:7
相关论文
共 30 条
[1]  
Alsabeeha NHM, 2009, INT J PROSTHODONT, V22, P429
[2]  
Bernardes SR, 2009, INT J ORAL MAX IMPL, V24, P781
[3]   Photoelastic stress analysis of various retention mechanisms on 3-implant-retained mandibular overdentures [J].
Celik, Gozde ;
Uludag, Bulent .
JOURNAL OF PROSTHETIC DENTISTRY, 2007, 97 (04) :229-235
[4]  
Chung Kwok-Hung, 2004, J Prosthodont, V13, P221
[5]  
Doukas D, 2008, INT J PROSTHODONT, V21, P152
[6]   The Change in Retentive Values of Locator Attachments and Hader Clips over Time [J].
Evtimovska, Elizabeta ;
Masri, Radi ;
Driscoll, Carl F. ;
Romberg, Elaine .
JOURNAL OF PROSTHODONTICS-IMPLANT ESTHETIC AND RECONSTRUCTIVE DENTISTRY, 2009, 18 (06) :479-483
[7]  
Feine J S, 2002, Int J Prosthodont, V15, P413
[8]  
Gulizio Michael P, 2005, J Prosthodont, V14, P3, DOI 10.1111/j.1532-849X.2005.00005.x
[9]   Overdenture attachment selection and the loading of implant and denture-bearing area. Part 2: A methodical study using five types of attachment [J].
Heckmann, SM ;
Winter, W ;
Meyer, M ;
Weber, HP ;
Wichmann, MG .
CLINICAL ORAL IMPLANTS RESEARCH, 2001, 12 (06) :640-647
[10]   Overdenture attachment selection and the loading of implant and denture-bearing area.: Part I:: In vivo verification of stereolithographic model [J].
Heckmann, SM ;
Winter, W ;
Meyer, M ;
Weber, HP ;
Wichmann, MG .
CLINICAL ORAL IMPLANTS RESEARCH, 2001, 12 (06) :617-623