Simultaneous Determination of Impurities of Atazanavir and Ritonavir in Tablet Dosage Form by Using Reversed-Phase Ultra Performance Liquid Chromatographic Method

被引:5
作者
Mantripragada, Murali Krishna V. V. N. [1 ]
Rao, Sumathi V. [1 ]
Nutulapati, Venugopal V. S. [2 ]
Mantena, Bhaskara P. V. [1 ]
机构
[1] APL Res Ctr, Survey 313, Hyderabad 500072, Telangana, India
[2] GITAM Univ, Visakhapatnam 530045, Andhra Pradesh, India
关键词
Drug dosage - Drug products - Liquid chromatography - Potassium compounds - Quality control;
D O I
10.1093/chromsci/bmx110
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
A simple, rapid, selective and stability indicating reversed phase-ultra performance liquid chromatography method was developed and validated for the simultaneous quantification of process related and degradation impurities present in Atazanavir and Ritonavir tablets. The two proposed drug components and their respective impurities were separated using Acquity BEH C18 (100 mm x 2.1 mm), 1.7 mu column at a flow rate of 0.4 mL/min. Buffer used as Mobile phase-A which consists of 0.01 M monobasic potassium hydrogen phosphate adjusted the pH to 3.6 and acetonitrile is used as organic modifier (mobile phase-B). The detector wavelength of 240 nm was used for quantifying the impurities. Both the drug components along with their impurities were eluted within a runtime of 18 min. The performance of the developed method was checked by validating the method according to the requirements of International Conference on Harmonization for parameters such as specificity, precision, linearity, ruggedness, accuracy, sensitivity (limit of detection (LOD) and limit of quantitation (LOQ)) and robustness. Linearity and range were established from LOQ level to 150% level. Accuracy of the method was demonstrated from LOQ level to 150% level. The developed stability indicating method is capable for determination of impurities of Atazanavir and Ritonavir in combined tablet dosage form as well as individual dosage forms also. The reported method enables lesser solvent consumption and reduces time and cost of the analysis in quality control laboratory.
引用
收藏
页码:270 / 284
页数:15
相关论文
共 24 条
[1]  
[Anonymous], GUID SUBM SAMPL AN D
[2]  
[Anonymous], 2005, Validation of analytical procedures: Text and methodology Q2 (R1)
[3]  
[Anonymous], 2000, Analytical Procedures and Methods Validation
[4]  
[Anonymous], 2012, VAL COMP METH 1225
[5]  
[Anonymous], 1990, OFFICIAL METHODS ANA, pXVII
[6]   Ultra-Performance Liquid Chromatographic Method for Simultaneous Quantification of HIV Non-Nucleoside Reverse Transcriptase Inhibitors and Protease Inhibitors in Human Plasma [J].
Antunes, Marina V. ;
Poeta, Julia ;
Ribeiro, Jorge P. ;
Sprinz, Eduardo ;
Linden, Rafael .
JOURNAL OF THE BRAZILIAN CHEMICAL SOCIETY, 2011, 22 (01) :134-141
[7]  
Anupama P., 2013, INT J RES PHARM CHEM, V3, P645
[8]   STATISTICAL CORRELATION AND SIMULTANEOUS ESTIMATION OF ATAZANAVIR SULFATE AND RITONAVIR IN FIXED DOSAGE FORM BY HIGH PERFORMANCE LIQUID CHROMATOGRAPHY AND HIGH PERFORMANCE THIN LAYER CHROMATOGRAPHY [J].
Behera, Anindita ;
Sethy, Kamini ;
Sankar, Dannana G. ;
Moitra, Swapan K. ;
Si, Sudam C. .
JOURNAL OF LIQUID CHROMATOGRAPHY & RELATED TECHNOLOGIES, 2012, 35 (12) :1731-1749
[9]   Determination of atazanavir in human plasma by high-performance liquid chromatography with UV detection [J].
Cattaneo, Dario ;
Maggiolo, Franco ;
Ripamonti, Diego ;
Perico, Norberto .
JOURNAL OF CHROMATOGRAPHIC SCIENCE, 2008, 46 (06) :485-489
[10]  
Deshpande Padmanabh B., 2014, J PHARM SCI INNOVATI, V3, P468