Evidences and magnitude of nighttime transpiration derived from Populus euphratica in the extreme arid region of China

被引:23
作者
Yu, Tengfei [1 ,2 ]
Feng, Qi [1 ,2 ]
Si, Jianhua [1 ,2 ]
Zhang, Xiaoyou [1 ,2 ]
Alec, Downey [3 ]
Zhao, Chunyan [1 ]
机构
[1] Chinese Acad Sci, Key Lab Ecohydrol Inland River Basin, Lanzhou 730000, Peoples R China
[2] Chinese Acad Sci, Northwest Inst Ecoenvironm & Resources, Alax Desert Ecohydrol Expt Res Stn, Lanzhou 730000, Peoples R China
[3] ICT Int Pty Ltd, Armidale, NSW 2350, Australia
基金
中国国家自然科学基金;
关键词
Nighttime transpiration; Populus euphratica; Sap flow; Stomatal conductance; NOCTURNAL STOMATAL CONDUCTANCE; SAP FLOW; WATER-USE; HYDRAULIC REDISTRIBUTION; LEAF; CO2; FOREST; PLANTS; C-3; RESPONSES;
D O I
10.1007/s12374-015-0536-4
中图分类号
Q94 [植物学];
学科分类号
071001 ;
摘要
Extensive research has found that nighttime transpiration (E (n)) is positively correlated to the vapour pressure deficit (VPD), that suggested E (n) was highest during the night under high temperatures and low humidity along with high soil water availability, typically for the riparian forest in the extreme arid region of China. This study used the heat ratio method to measure sap velocity (V (s)) for mature and saplings Populus euphratica Oliv., and then E (n) was conservatively calculated as total nocturnal sap flow (F (s), the product of V (s) and sapwood area A (s)) between 01:00 to 06:00. A gas exchange system was used to measure the leaf transpiration rate (T (r)) and stomatal conductance (g (s)) of saplings. For mature trees, nighttime V (s) was extensive and logarithmic correlated to VPD (similar to daytime). For saplings, g (s) and T (r) was extensive in different months, and also a strong logarithmic relationship was found between V (s) and VPD for both daytime and nighttime periods. Both of stem sap flow and leaf gas exchange suggusted the occurrence of E (n), whether mature or sapling trees. E (n) contribution to daily transpiration (E (d)) was high just as expected for P. euphratica, which was confirmed by proportional E (n) to E (d) (E (n)/E (d)) means taken in 2012 (24.99%) and 2013 (34.08%). Compared to mature trees, E (n)/E (d) of saplings in 2013 was lower with means of 12.06%, that supported further by the shorter duration times and less T (r,n) (16.64%) and g (s,n) (26.45%) of leaf, suggesting that E (n) magnitude is associated to individual the tree size, that effect to stored water of individual trees, although this hypothesis requires further research.
引用
收藏
页码:648 / 657
页数:10
相关论文
共 39 条
  • [1] Alvarado-Barrientos MS, 2014, TREES-STRUCT FUNCT, V29, P259
  • [2] Comparative study of diurnal and nocturnal sap flow of Quercus ilex and Phillyrea latifolia in a Mediterranean holm oak forest in Prades (Catalonia, NE Spain)
    Barbeta, Adria
    Ogaya, Roma
    Penuelas, Josep
    [J]. TREES-STRUCTURE AND FUNCTION, 2012, 26 (05): : 1651 - 1659
  • [3] The stomatal response to evaporative demand persists at night in Ricinus communis plants with high nocturnal conductance
    Barbour, Margaret M.
    Buckley, Thomas N.
    [J]. PLANT CELL AND ENVIRONMENT, 2007, 30 (06) : 711 - 721
  • [4] Nocturnal stomatal conductance and implications for modelling δ18O of leaf-respired CO2 in temperate tree species
    Barbour, MM
    Cernusak, LA
    Whitehead, D
    Griffin, KL
    Turnbull, MH
    Tissue, DT
    Farquhar, GD
    [J]. FUNCTIONAL PLANT BIOLOGY, 2005, 32 (12) : 1107 - 1121
  • [5] Benyon RG, 1999, TREE PHYSIOL, V19, P853
  • [6] Processes preventing nocturnal equilibration between leaf and soil water potential in tropical savanna woody species
    Bucci, SJ
    Scholz, FG
    Goldstein, G
    Meinzer, FC
    Hinojosa, JA
    Hoffmann, WA
    Franco, AC
    [J]. TREE PHYSIOLOGY, 2004, 24 (10) : 1119 - 1127
  • [7] An improved heat pulse method to measure low and reverse rates of sap flow in woody plants
    Burgess, SSO
    Adams, MA
    Turner, NC
    Beverly, CR
    Ong, CK
    Khan, AAH
    Bleby, TM
    [J]. TREE PHYSIOLOGY, 2001, 21 (09) : 589 - 598
  • [8] Nighttime stomatal conductance and transpiration in C3 and C4 plants
    Caird, Mairgareth A.
    Richards, James H.
    Donovan, Lisa A.
    [J]. PLANT PHYSIOLOGY, 2007, 143 (01) : 4 - 10
  • [9] Campbell G. S., 1998, INTRO ENV BIOPHYSICS
  • [10] Atmospheric and soil drought reduce nocturnal conductance in live oaks
    Cavender-Bares, Jeannine
    Sack, Lawren
    Savage, Jessica
    [J]. TREE PHYSIOLOGY, 2007, 27 (04) : 611 - 620