Study on the long-term passive cooling extension of AP1000 reactor

被引:0
|
作者
Ye Cheng [1 ,2 ]
Zheng Mingguang [2 ]
Wang Yong [2 ,3 ]
Qiu Zhongming [1 ,2 ]
机构
[1] Shanghai Jiao Tong Univ, Sch Nucl Sci & Engn, Shanghai 200240, Peoples R China
[2] Shanghai Nucl Engn Res & Design Inst, Shanghai 200233, Peoples R China
[3] Zhejiang Univ, Hangzhou 310058, Zhejiang, Peoples R China
关键词
Passive cooling; Passive containment cooling system; WGOTHIC;
D O I
暂无
中图分类号
TL [原子能技术]; O571 [原子核物理学];
学科分类号
0827 ; 082701 ;
摘要
The AP1000 with high safety is a generation III pressurized water reactor (PWR), its significant feature is passive safety system. However, its passive cooling can only maintain for 72 h and requires additional support from inside or outside the plant. To solve this problem, this study utilized the WGOTHIC software to calculate and analyze the water inventory in the passive containment cooling water tank under different conditions. The results show that when the cooling water inventory is 6553.78 m(3), the AP1000 nuclear power plants can achieve long-term, completely passive cooling without any inside or outside the plant. The same outcomes occur when 65-mm-thick containment wall increases the design pressure rating to 0.6 M-Pa at the cooling water inventory of 5673 m(3). Also, the AP1000 shield building was accordingly improved. An ANSYS analysis of the structural stability of the shield building with a 6000 m(3) cooling water inventory confirmed that the new design can meet the requirements of the seismic design and the safe residual heat removal requirements of a large-scale PWR.
引用
收藏
页数:7
相关论文
共 50 条
  • [31] Development of a dynamic simulation program of AP1000 reactor core
    Liu, Yang
    Wang, Zhao
    Kuang, Hongbo
    Bu, Jiangtao
    Zhao, Fuyu
    Hedongli Gongcheng/Nuclear Power Engineering, 2014, 35 (03): : 173 - 176
  • [32] Study of impact of the AP1000® reactor vessel upper internals design on fuel performance
    Xu, Yiban
    Conner, Michael
    Yuan, Kun
    Dzodzo, Milorad B.
    Karoutas, Zeses
    Beltz, Steven A.
    Ray, Sumit
    Bissett, Teresa A.
    Chieng, Ching-Chang
    Kao, Min-Tsung
    Wu, Chung-Yun
    NUCLEAR ENGINEERING AND DESIGN, 2012, 252 : 128 - 134
  • [33] Prediction of falling film evaporation on the AP1000 paSsive containment cooling system using ANSYS FLUENT code
    Wang, Xianmao
    Chang, Huajian
    Corradini, Michael
    Cong, Tenglong
    Wang, Jun
    ANNALS OF NUCLEAR ENERGY, 2016, 95 : 168 - 175
  • [34] Thermal-hydraulic and stress analysis of AP1000 reactor containment during LOCA in dry cooling mode
    Sh. Sheykhi
    S. Talebi
    M. Soroush
    E. Masoumi
    Nuclear Science and Techniques, 2017, 28
  • [35] Thermal-hydraulic and stress analysis of AP1000 reactor containment during LOCA in dry cooling mode
    Sh.Sheykhi
    S.Talebi
    M.Soroush
    E.Masoumi
    NuclearScienceandTechniques, 2017, 28 (06) : 89 - 101
  • [36] Thermal-hydraulic and stress analysis of AP1000 reactor containment during LOCA in dry cooling mode
    Sheykhi, Sh.
    Talebi, S.
    Soroush, M.
    Masoumi, E.
    NUCLEAR SCIENCE AND TECHNIQUES, 2017, 28 (06)
  • [37] PASSIVE SAFETY SYSTEMS OF ADVANCED NUCLEAR POWER PLANT: AP1000
    Yan, Guohua
    Ye, Chen
    PROCEEDINGS OF THE 18TH INTERNATIONAL CONFERENCE ON NUCLEAR ENGINEERING 2010, VOL 6, 2011, : 85 - 89
  • [38] Detailed neutronic calculations of the AP1000 reactor core with the Serpent code
    de Stefani, Giovanni Laranjo
    Losada Moreira, Joao Manoel
    Maiorino, Jose Rubens
    Russo Rossi, Pedro Carlos
    PROGRESS IN NUCLEAR ENERGY, 2019, 116 : 95 - 107
  • [39] Heat removal analysis in the AP1000 reactor's refuelling process
    Isnaini, Muh Darwis
    Subekti, M.
    SYMPOSIUM OF EMERGING NUCLEAR TECHNOLOGY AND ENGINEERING NOVELTY (SENTEN 2018), 2019, 1198
  • [40] APPLICATION OF AN IMPROVED MECHANICAL SHIM CONTROL STRATEGY FOR AP1000 REACTOR
    Wang, Pengfei
    Wan, Jiashuang
    Yan, Shoujun
    Liu, Yang
    Zhao, Fuyu
    NUCLEAR TECHNOLOGY, 2014, 187 (03) : 243 - 259