Study on the long-term passive cooling extension of AP1000 reactor

被引:0
|
作者
Ye Cheng [1 ,2 ]
Zheng Mingguang [2 ]
Wang Yong [2 ,3 ]
Qiu Zhongming [1 ,2 ]
机构
[1] Shanghai Jiao Tong Univ, Sch Nucl Sci & Engn, Shanghai 200240, Peoples R China
[2] Shanghai Nucl Engn Res & Design Inst, Shanghai 200233, Peoples R China
[3] Zhejiang Univ, Hangzhou 310058, Zhejiang, Peoples R China
关键词
Passive cooling; Passive containment cooling system; WGOTHIC;
D O I
暂无
中图分类号
TL [原子能技术]; O571 [原子核物理学];
学科分类号
0827 ; 082701 ;
摘要
The AP1000 with high safety is a generation III pressurized water reactor (PWR), its significant feature is passive safety system. However, its passive cooling can only maintain for 72 h and requires additional support from inside or outside the plant. To solve this problem, this study utilized the WGOTHIC software to calculate and analyze the water inventory in the passive containment cooling water tank under different conditions. The results show that when the cooling water inventory is 6553.78 m(3), the AP1000 nuclear power plants can achieve long-term, completely passive cooling without any inside or outside the plant. The same outcomes occur when 65-mm-thick containment wall increases the design pressure rating to 0.6 M-Pa at the cooling water inventory of 5673 m(3). Also, the AP1000 shield building was accordingly improved. An ANSYS analysis of the structural stability of the shield building with a 6000 m(3) cooling water inventory confirmed that the new design can meet the requirements of the seismic design and the safe residual heat removal requirements of a large-scale PWR.
引用
收藏
页数:7
相关论文
共 50 条
  • [21] A Fuzzy Probability Algorithm for Evaluating the AP1000 Long Term Cooling System to Mitigate Large Break LOCA
    Purba, J. H.
    ATOM INDONESIA, 2015, 41 (03) : 113 - 121
  • [22] Analysis of AP1000 containment passive cooling system during a loss-of-coolant accident
    Hung, Zhen-Yu
    Ferng, Yuh-Ming
    Hsu, Wen-Sheng
    Pei, Bau-Shei
    Chen, Yen-Shu
    ANNALS OF NUCLEAR ENERGY, 2015, 85 : 717 - 724
  • [23] AP1000® PASSIVE CORE COOLING SYSTEM PERFORMANCE FOLLOWING AN EXTENDED STATION BLACKOUT EVENT
    Wright, Richard F.
    Swantner, Stephen
    Swartz, Matthew M.
    Lojek, John
    Song, Yong Jae
    Kindred, T. A.
    PROCEEDINGS OF THE 22ND INTERNATIONAL CONFERENCE ON NUCLEAR ENGINEERING - 2014, VOL 3, 2014,
  • [24] Simulation of AP1000's passive containment cooling with the German Containment Code System COCOSYS
    Broxtermann, Philipp
    Allelein, Hans-Josef
    NUCLEAR ENGINEERING AND DESIGN, 2013, 261 : 326 - 332
  • [25] Effect of Nu correlation uncertainty on safety margin for passive containment cooling system in AP1000
    Yu, Yu
    Wang, Shengfei
    Niu, Fenglei
    Lai, Yinshan
    Kuang, Zhijin
    PROGRESS IN NUCLEAR ENERGY, 2015, 79 : 1 - 7
  • [26] Neutronic Analysis of the AP1000 Pressurized Water Reactor
    Brzezinski, Mikolaj
    Sierchula, Jakub
    CHALLENGES AND RECENT ADVANCEMENTS IN NUCLEAR ENERGY SYSTEMS, SCOPE 2023, 2024, : 619 - 631
  • [27] NUMERICAL RESEARCH ON PERFORMANCE OF AP1000 PASSIVE CONTAINMENT COOLING SYSTEM WITHOUT FALLING FILM
    Wang Hui
    Guo Qiang
    Chen Qiaoyan
    PROCEEDINGS OF THE 21ST INTERNATIONAL CONFERENCE ON NUCLEAR ENGINEERING - 2013, VOL 3, 2014,
  • [28] THERMAL HYDRAULIC PERFORMANCE ANALYSIS FOR PASSIVE CONTAINMENT COOLING SYSTEM OF AP1000 IN THE EVENT OF LOCA
    Bin Mujahid, Talha
    Yu, Yu
    Wang, Bin
    Shahzad, Muhammad Ali
    Niu, Fenglei
    PROCEEDINGS OF THE 25TH INTERNATIONAL CONFERENCE ON NUCLEAR ENGINEERING, 2017, VOL 6, 2017,
  • [29] Analysis of N-16 Concentration in Primary Cooling System of AP1000 Power Reactor
    Rohanda, Anis
    Waris, Abdul
    5TH ASIAN PHYSICS SYMPOSIUM (APS 2012), 2015, 1656
  • [30] Transformation of Pressurized Water Reactor AP1000 to Fuzzy Graph
    Ashaari, Azmirul
    Ahmad, Tahir
    Mohamad, Wan Munirah Wan
    MATEMATIKA, 2018, 34 (02) : 235 - 244