Study on the long-term passive cooling extension of AP1000 reactor

被引:0
|
作者
Ye Cheng [1 ,2 ]
Zheng Mingguang [2 ]
Wang Yong [2 ,3 ]
Qiu Zhongming [1 ,2 ]
机构
[1] Shanghai Jiao Tong Univ, Sch Nucl Sci & Engn, Shanghai 200240, Peoples R China
[2] Shanghai Nucl Engn Res & Design Inst, Shanghai 200233, Peoples R China
[3] Zhejiang Univ, Hangzhou 310058, Zhejiang, Peoples R China
关键词
Passive cooling; Passive containment cooling system; WGOTHIC;
D O I
暂无
中图分类号
TL [原子能技术]; O571 [原子核物理学];
学科分类号
0827 ; 082701 ;
摘要
The AP1000 with high safety is a generation III pressurized water reactor (PWR), its significant feature is passive safety system. However, its passive cooling can only maintain for 72 h and requires additional support from inside or outside the plant. To solve this problem, this study utilized the WGOTHIC software to calculate and analyze the water inventory in the passive containment cooling water tank under different conditions. The results show that when the cooling water inventory is 6553.78 m(3), the AP1000 nuclear power plants can achieve long-term, completely passive cooling without any inside or outside the plant. The same outcomes occur when 65-mm-thick containment wall increases the design pressure rating to 0.6 M-Pa at the cooling water inventory of 5673 m(3). Also, the AP1000 shield building was accordingly improved. An ANSYS analysis of the structural stability of the shield building with a 6000 m(3) cooling water inventory confirmed that the new design can meet the requirements of the seismic design and the safe residual heat removal requirements of a large-scale PWR.
引用
收藏
页数:7
相关论文
共 50 条
  • [1] Study on the long-term passive cooling extension of AP1000 reactor
    YE Cheng
    ZHENG Mingguang
    WANG Yong
    QIU Zhongming
    Nuclear Science and Techniques, 2013, 24 (04) : 70 - 76
  • [2] WESTINGHOUSE AP1000 SOLUTION TO LONG-TERM COOLING DEBRIS CONCERNS
    Schulz, Terry L.
    Andreychek, Timothy S.
    Song, Yong J.
    McNamee, Kevin F.
    PROCEEDINGS OF THE 17TH INTERNATIONAL CONFERENCE ON NUCLEAR ENGINEERING, VOL 2, 2009, : 757 - 764
  • [3] AP1000 VERIFICAITON OF WATER SOURCES FOR LONG-TERM RECIRCULATION COOLING FOLLOWING A LOCA
    Andreychek, T. S.
    Schulz, T. L.
    Densmore, W. E.
    Brown, A. C.
    ICONE 16: PROCEEDING OF THE 16TH INTERNATIONAL CONFERENCE ON NUCLEAR ENGINEERING - 2008, VOL 4, 2008, : 493 - 498
  • [4] The AP1000™ Reactor: Passive Safety and Modular Design
    Sutharshan, Balendra
    Mutyala, Meena
    Vijuk, Ronald P.
    Mishra, Alok
    ASIAN NUCLEAR PROSPECTS 2010, 2011, 7 : 293 - 302
  • [5] RELIABILITY ASSESSMENT OF REACTOR AP1000 PASSIVE ERVC SYSTEM
    Cui Chengxin
    Huang Ting
    Chen Lian
    Chen Ying
    Zhang Lei
    PROCEEDINGS OF THE 25TH INTERNATIONAL CONFERENCE ON NUCLEAR ENGINEERING, 2017, VOL 4, 2017,
  • [6] Study of the Reactor Control System of MSHIM in AP1000
    Wei, Xinyu
    Zhao, Fuyu
    SCIENCE AND TECHNOLOGY OF NUCLEAR INSTALLATIONS, 2015, 2015
  • [7] Preliminary Study of Plutonium Utilization in AP1000 Reactor
    Nailatussaadah
    Prastyo, Puguh A.
    Waris, Abdul
    Kurniadi, Rizal
    Pramuditya, Syeilendra
    INTERNATIONAL CONFERENCE ON ENERGY SCIENCES (ICES 2016), 2017, 877
  • [8] Major Milestones for the AP1000 Reactor
    不详
    POWER, 2011, 155 (02) : 8 - 8
  • [9] AP1000® Passive Cooling Containment Analysis With Computational Fluid Dynamics Codes
    Jimenez, Gonzalo
    Goni, Zurine
    del Rio, Gonzalo
    Estevez, Samanta
    Queral, Cesar
    26TH INTERNATIONAL CONFERENCE NUCLEAR ENERGY FOR NEW EUROPE (NENE 2017), 2017,
  • [10] THERMAL - HYDRAULIC PERFORMANCE ANALYSIS FOR AP1000 PASSIVE CONTAINMENT COOLING SYSTEM
    Yu, Yu
    Wang, Shengfei
    Niu, Fenglei
    PROCEEDINGS OF THE 21ST INTERNATIONAL CONFERENCE ON NUCLEAR ENGINEERING - 2013, VOL 4, 2014,