摘要
The control strategy is very important for semi-active control or active control systems. An integrated intelligent control strategy for building structures incorporated with magnetorheological (MR) dampers subjected to earthquake excitation is proposed. In this strategy, the time-delay problem is solved by a neural network and the control currents of the MR dampers are determined quickly by a fuzzy controller. Through a numerical example of a three-storey structure with one MR damper installed in the first floor, the seismic responses of the uncontrolled, the intelligently controlled, the passive-on controlled, and the passive-off controlled structures under different earthquake excitations are analyzed. Based on the numerical results, it can be found that the time domain and the frequency domain responses are reduced effectively when the MR damper is added in the structure, and the integrated intelligent control strategy has a better earthquake mitigation effect.
引用
收藏
页码:2280 / 2294
页数:15
相关论文
共 50 条
  • [41] Nondimensional analysis of semi-active electrorheological and magnetorheological dampers using approximate parallel plate models
    Wereley, NM
    Pang, L
    SMART MATERIALS & STRUCTURES, 1998, 7 (05): : 732 - 743
  • [42] Active/semi-active suspension control using magnetorheological actuators
    Karkoub, MA
    Zribi, M
    INTERNATIONAL JOURNAL OF SYSTEMS SCIENCE, 2006, 37 (01) : 35 - 44
  • [43] Nondimensional analysis of semi-active electrorheological and magnetorheological dampers using approximate parallel plate models
    Wereley, Norman M.
    Li, Pang
    Smart Materials and Structures, 1998, 7 (05): : 732 - 743
  • [44] Harmonic analysis of semi-active control with MR dampers
    Liao, WH
    Lai, CY
    SMART STRUCTURES AND MATERIALS 2002: DAMPING AND ISOLATION, 2002, 4697 : 370 - 381
  • [45] SEMI-ACTIVE ISOLATION SYSTEM USING SELF-POWERED MAGNETORHEOLOGICAL DAMPERS
    Choi, Young-Tai
    Song, Hyun Jeong
    Wereley, Norman M.
    SMASIS2009, VOL 2, 2009, : 295 - 304
  • [46] Semi-active control of friction dampers
    Dupont, P
    Kasturi, P
    Stokes, A
    JOURNAL OF SOUND AND VIBRATION, 1997, 202 (02) : 203 - 218
  • [47] Characterization of semi-active Magnetorheological helicopter lag mode dampers
    Kamath, GM
    Wereley, NM
    Jolly, MR
    SMART STRUCTURES AND MATERIALS 1998: SMART STRUCTURES AND INTEGRATED SYSTEMS, PTS 1 AND 2, 1998, 3329 : 356 - 377
  • [48] Semi-active neuro-control for base-isolation system using magnetorheological (MR) dampers
    Bani-Hani, Khaldoon A.
    Sheban, Mashal A.
    EARTHQUAKE ENGINEERING & STRUCTURAL DYNAMICS, 2006, 35 (09): : 1119 - 1144
  • [49] Adaptive Sliding Mode Fault-Tolerant Control for Semi-Active Suspension Using Magnetorheological Dampers
    Dong, Xiaomin
    Yu, Miao
    Guan, Zhi
    JOURNAL OF INTELLIGENT MATERIAL SYSTEMS AND STRUCTURES, 2011, 22 (15) : 1653 - 1660
  • [50] Semi-active control of structures using a neuro-inverse model of MR dampers
    Khaje-Karamodin, A.
    Haji-Kazemi, H.
    Rowhanimanesh, A.R.
    Akbarzadeh-Tootoonchi, M.R.
    Scientia Iranica, 2009, 16 (03) : 256 - 263