Design guidelines for an electron diffractometer for structural chemistry and structural biology

被引:17
作者
Heidler, Jonas [1 ]
Pantelic, Radosav [2 ]
Wennmacher, Julian T. C. [1 ]
Zaubitzer, Christian [3 ]
Fecteau-Lefebvre, Ariane [4 ]
Goldie, Kenneth N. [4 ]
Mueller, Elisabeth [1 ]
Holstein, Julian J. [5 ]
van Genderen, Eric [1 ]
De Carlo, Sacha [2 ]
Gruene, Tim [1 ,6 ]
机构
[1] Paul Scherrer Inst, CH-5232 Villigen, Switzerland
[2] DECTRIS Ltd, CH-5405 Baden, Switzerland
[3] Swiss Fed Inst Technol, Sci Ctr Opt & Electron Microscopy, CH-8093 Zurich, Switzerland
[4] Univ Basel, Ctr Cellular Imaging & NanoAnalyt, CH-4058 Basel, Switzerland
[5] TU Dortmund Univ, Fac Chem & Chem Biol, Otto Hahn Str 6, D-44227 Dortmund, Germany
[6] Univ Wien, Fac Chem, Zentrum Rontgenstrukturanal, A-1090 Vienna, Austria
来源
ACTA CRYSTALLOGRAPHICA SECTION D-STRUCTURAL BIOLOGY | 2019年 / 75卷
基金
瑞士国家科学基金会;
关键词
electron diffractometer; EIGER X 1M detector; 3D electron diffraction; chemical crystallography; EIGER hybrid pixel detector; structural chemistry; RAY-DIFFRACTION DATA; CRYSTALLOGRAPHY; ILLUMINATION; TOMOGRAPHY; POSITIONS; TEM;
D O I
10.1107/S2059798319003942
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
3D electron diffraction has reached a stage where the structures of chemical compounds can be solved productively. Instrumentation is lagging behind this development, and to date dedicated electron diffractometers for data collection based on the rotation method do not exist. Current studies use transmission electron microscopes as a workaround. These are optimized for imaging, which is not optimal for diffraction studies. The beam intensity is very high, it is difficult to create parallel beam illumination and the detectors used for imaging are of only limited use for diffraction studies. In this work, the combination of an EIGER hybrid pixel detector with a transmission electron microscope to construct a productive electron diffractometer is described. The construction not only refers to the combination of hardware but also to the calibration of the system, so that it provides rapid access to the experimental parameters that are necessary for processing diffraction data. Until fully integrated electron diffractometers become available, this describes a setup for productive and efficient operation in chemical crystallography.
引用
收藏
页码:458 / 466
页数:9
相关论文
共 53 条
[1]   Accurate lattice-parameter determination from electron diffraction tomography data using two-dimensional diffraction vectors [J].
Angstrom, Jonas ;
Chen, Hong ;
Wan, Wei .
JOURNAL OF APPLIED CRYSTALLOGRAPHY, 2018, 51 :982-989
[2]  
[Anonymous], SAINT PLUS AND XPREP
[3]  
[Anonymous], 2011, Electron Crystallography: Electron Microscopy and Electron Diffraction
[4]  
[Anonymous], ACTA CRYST B, DOI DOI 10.1107/S2052520616003954
[5]  
Arndt W. W., 1977, ROTATION METHOD CRYS
[6]  
Arvai A. S., 2018, PROGRAM DISPLAY XRAY
[7]  
Baerlocher C., 2016, Database of zeolite structures
[8]   KOHLER ILLUMINATION IN THE TEM - FUNDAMENTALS AND ADVANTAGES [J].
BENNER, G ;
PROBST, W .
JOURNAL OF MICROSCOPY-OXFORD, 1994, 174 :133-142
[9]   Neutron crystallography: opportunities, challenges, and limitations [J].
Blakeley, Matthew P. ;
Langan, Paul ;
Niimura, Nobuo ;
Podjarny, Alberto .
CURRENT OPINION IN STRUCTURAL BIOLOGY, 2008, 18 (05) :593-600
[10]   Small molecule conformational preferences derived from crystal structure data. A medicinal chemistry focused analysis [J].
Brameld, Ken A. ;
Kuhn, Bernd ;
Reuter, Deborah C. ;
Stahl, Martin .
JOURNAL OF CHEMICAL INFORMATION AND MODELING, 2008, 48 (01) :1-24