Differentiation of prostatic carcinoma and benign prostatic hyperplasia: Correlation between dynamic Gd-DTPA-enhanced MR imaging and histopathology

被引:0
作者
Turnbull, LW [1 ]
Buckley, DL [1 ]
Turnbull, LS [1 ]
Liney, GP [1 ]
Knowles, AJ [1 ]
机构
[1] Hull Royal Infirm, Ctr Magnet Resonance Invest, Dept Med Phys, Hull HU3 2JZ, N Humberside, England
来源
JMRI-JOURNAL OF MAGNETIC RESONANCE IMAGING | 1999年 / 9卷 / 02期
关键词
dynamic MR imaging; histopathology; prostate;
D O I
10.1002/(SICI)1522-2586(199902)9:2<311::AID-JMRI24>3.3.CO;2-N
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
One of the major factors limiting the staging accuracy of conventional magnetic resonance imaging (MRI) for prostatic carcinoma, is the similarity in signal intensity between tumor and coexisting benign prostatic hyperplasia (BPH). As neovascularity is an independent indicator of pathological state, dynamic contrast-enhanced MRI may yield additional information, This study correlates the histopathological findings from 12 radical prostatectomy patients on a region-by-region basis, with pharmacokinetic modeling of dynamic contrast-enhanced (0.2 mmol dimeglumine gadopentetate/kg), fast multiplanar spoilt gradient-recalled echo images, using a two-compartment simplex minimization technique. Quantitative analysis demonstrated differences in the amplitude of the initial contrast upslope and contrast exchange rate between tumor and fibromuscular BPH (P < 0.03 and P < 0.03, respectively) and for the contrast exchange rate between tumor and fibroglandular BPH (P < 0.04), providing improved delineation of intraprostatic tumor extent compared with conventional imaging techniques. J. Magn. reson. Imaging 1999; 9:311-31.6, (C) 1999 Wiley-Liss, Inc.
引用
收藏
页码:311 / 316
页数:6
相关论文
共 14 条
[1]   CONTRAST-ENHANCED ENDORECTAL COIL MRI IN LOCAL STAGING OF PROSTATE CARCINOMA [J].
BONI, RAH ;
BONER, JA ;
LUTOLF, UM ;
TRINKLER, F ;
PESTALOZZI, DM ;
KRESTIN, GP .
JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1995, 19 (02) :232-237
[2]  
BREM RF, 1990, J UROLOGY, V143, P195
[3]   QUANTITATIVE-ANALYSIS OF MULTISLICE GD-DTPA ENHANCED DYNAMIC MR-IMAGES USING AN AUTOMATED SIMPLEX MINIMIZATION PROCEDURE [J].
BUCKLEY, DL ;
KERSLAKE, RW ;
BLACKBAND, SJ ;
HORSMAN, A .
MAGNETIC RESONANCE IN MEDICINE, 1994, 32 (05) :646-651
[4]   USE OF ENDORECTAL SURFACE COIL MAGNETIC-RESONANCE-IMAGING FOR LOCAL STAGING OF PROSTATE-CANCER [J].
CHELSKY, MJ ;
SCHNALL, MD ;
SEIDMON, EJ ;
POLLACK, HM .
JOURNAL OF UROLOGY, 1993, 150 (02) :391-395
[5]   METHOD FELL THE QUANTITATIVE ASSESSMENT OF CONTRAST AGENT UPTAKE IN DYNAMIC CONTRAST-ENHANCED MRT [J].
HITTMAIR, K ;
GOMISCEK, G ;
LANGENBERGER, K ;
RECHT, M ;
IMHOF, H ;
KRAMER, J .
MAGNETIC RESONANCE IN MEDICINE, 1994, 31 (05) :567-571
[6]  
JAGER GJ, 1994, RADIOLOGE, V34, P129
[7]   PROSTATIC-CARCINOMA AND BENIGN PROSTATIC HYPERPLASIA - MR IMAGING WITH HISTOPATHOLOGIC CORRELATION [J].
KAHN, T ;
BURRIG, K ;
SCHMITZDRAGER, B ;
LEWIN, JS ;
FURST, G ;
MODDER, U .
RADIOLOGY, 1989, 173 (03) :847-851
[8]   MR IMAGING OF THE BREAST - FAST IMAGING SEQUENCES WITH AND WITHOUT GD-DTPA - PRELIMINARY-OBSERVATIONS [J].
KAISER, WA ;
ZEITLER, E .
RADIOLOGY, 1989, 170 (03) :681-686
[9]  
LENCIONI R, 1995, 12 C SMR, P1501
[10]  
NISHIMURA K, 1988, ACTA UROL JPN, V34, P2097