Eutectic-based wafer-level-packaging technique for piezoresistive MEMS accelerometers and bond characterization using molecular dynamics simulations

被引:3
作者
Aono, T. [1 ,2 ]
Kazama, A. [1 ]
Okada, R. [1 ]
Iwasaki, T. [1 ]
Isono, Y. [2 ]
机构
[1] Hitachi Ltd, Res & Dev Grp, 832-2 Horiguchi, Hitachinaka, Ibaraki 8322, Japan
[2] Kobe Univ, Dept Mech Engn, Kobe, Hyogo, Japan
关键词
eutectic bonding; wafer-level-packaging; molecular dynamics simulation; accelerometer; shear strength; air damping;
D O I
10.1088/1361-6439/aaa2d8
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
We developed a eutectic-based wafer-level-packaging (WLP) technique for piezoresistive micro-electromechanical systems (MEMS) accelerometers on the basis of molecular dynamics analyses and shear tests of WLP accelerometers. The bonding conditions were experimentally and analytically determined to realize a high shear strength without solder material atoms diffusing to adhesion layers. Molecular dynamics (MD) simulations and energy dispersive x-ray (EDX) spectrometry done after the shear tests clarified the eutectic reaction of the solder materials used in this research. Energy relaxation calculations in MD showed that the diffusion of solder material atoms into the adhesive layer was promoted at a higher temperature. Tensile creep MD simulations also suggested that the local potential energy in a solder material model determined the fracture points of the model. These numerical results were supported by the shear tests and EDX analyses for WLP accelerometers. Consequently, a bonding load of 9.8 kN and temperature of 300 degrees C were found to be rational conditions because the shear strength was sufficient to endure the polishing process after the WLP process and there was little diffusion of solder material atoms to the adhesion layer. Also, eutectic-bonding-based WLP was effective for controlling the attenuation of the accelerometers by determining the thickness of electroplated solder materials that played the role of a cavity between the accelerometers and lids. If the gap distance between the two was less than 6.2 mu m, the signal gains for x-and z-axis acceleration were less than 20 dB even at the resonance frequency due to air-damping.
引用
收藏
页数:11
相关论文
共 24 条
[1]   A COMPARISON OF SQUEEZE-FILM THEORY WITH MEASUREMENTS ON A MICROSTRUCTURE [J].
ANDREWS, M ;
HARRIS, I ;
TURNER, G .
SENSORS AND ACTUATORS A-PHYSICAL, 1993, 36 (01) :79-87
[2]  
[Anonymous], ADV NAT SCI NANOSCI
[3]   Localized silicon fusion and eutectic bonding for MEMS fabrication and packaging [J].
Cheng, YT ;
Lin, LW ;
Najafi, K .
JOURNAL OF MICROELECTROMECHANICAL SYSTEMS, 2000, 9 (01) :3-8
[4]   Wafer level packaging of MEMS [J].
Esashi, Masayoshi .
JOURNAL OF MICROMECHANICS AND MICROENGINEERING, 2008, 18 (07)
[5]  
Fang Z, 2010, J MICROMECH MICROENG, V22
[6]   Integrating MEMS and ICs [J].
Fischer, Andreas C. ;
Forsberg, Fredrik ;
Lapisa, Martin ;
Bleiker, Simon J. ;
Stemme, Goran ;
Roxhed, Niclas ;
Niklaus, Frank .
MICROSYSTEMS & NANOENGINEERING, 2015, 1
[7]   New Automotive Sensors-A Review [J].
Fleming, William J. .
IEEE SENSORS JOURNAL, 2008, 8 (11-12) :1900-1921
[8]   Performance of a Sensitive Micromachined Accelerometer With an Electrostatically Suspended Proof Mass [J].
Han, Fengtian ;
Sun, Boqian ;
Li, Linlin ;
Wu, Qiuping .
IEEE SENSORS JOURNAL, 2015, 15 (01) :209-217
[9]   DESIGN CONSIDERATIONS FOR THE THERMAL ACCELEROMETER [J].
HIRATSUKA, R ;
VANDUYN, DC ;
OTAREDIAN, T ;
DEVRIES, P ;
SARRO, PM .
SENSORS AND ACTUATORS A-PHYSICAL, 1992, 32 (1-3) :380-385
[10]   CANONICAL DYNAMICS - EQUILIBRIUM PHASE-SPACE DISTRIBUTIONS [J].
HOOVER, WG .
PHYSICAL REVIEW A, 1985, 31 (03) :1695-1697