Sterility screening of platelet concentrates:: questioning the optimal test strategy

被引:25
作者
Dreier, J. [1 ]
Stoermer, M. [1 ]
Pichl, L. [2 ]
Schottstedt, V. [2 ]
Grolle, A. [3 ]
Bux, J. [2 ]
Kleesiek, K. [1 ]
机构
[1] Ruhr Univ Bochum, Univ Klin, Inst Labs & Transfus Med Herz & Diabet Zentrum No, D-32545 Bad Oeynhausen, Germany
[2] Zent Labor, DRK Blutspendedienst W, Hagen, Germany
[3] Zentrum Transfus Med, DRK Blutspendedienst W, Hagen, Germany
关键词
bacterial contamination; blood safety; quality control; sampling error; sterility testing;
D O I
10.1111/j.1423-0410.2008.01087.x
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background Routine bacterial monitoring of apheresis platelet concentrates (APC) and pooled platelet concentrates (PPC) was introduced in two German blood services using culture and real-time reverse transcriptase (RT)-polymerase chain reaction (PCR). The results of testing are reviewed and used to discuss different strategies for detection of bacterial contamination of PCs. Study Design and Methods Two thousand three hundred and sixty-two APCs and 1993 PPCs have been tested by real-time RT-PCR and the BacT/Alert automated culturing system using aerobic and anaerobic culture bottles. After standard processing of PCs and storage of 22-24 h at 20-24 degrees C with agitation, samples were taken under aseptic conditions. Reactive culture bottles were confirmed as positive and bacterial isolates were identified by 16S rRNA analysis and biochemical tests. Results Seventeen of 2362 tested APCs were reactive in culture and one also in RT-PCR. Of these, 13 APCs were identified as initially positive as Staphylococcus warneri (n = 1, positive in aerobic and anaerobic culture), Propionibacterium acnes (n = 12, positive only in anaerobic culture) and four were initially reactive. Two of 1993 PPCs were initially reactive (anaerobic) and two more were confirmed positive (anaerobic) from a repeat culture and identified as P. acnes. All remaining specimens were tested negative. Conclusion Our study demonstrates that the predominant organisms implicated in platelet bacterial contamination are part of the human skin flora. Inoculating blood culture systems and anaerobic cultivation detects these bacteria after approximately 3-7 days when blood products have been transfused. Based on the presented data different screening strategies are discussed.
引用
收藏
页码:181 / 188
页数:8
相关论文
共 33 条
[1]   The reliability of bacterial detection in platelets [J].
AuBuchon, J. P. .
ISBT SCIENCE SERIES, VOL 1, NO 1: STATE OF THE ART PRESENTATIONS, 2006, 1 (01) :59-63
[2]   Bacterial detection and extended platelet storage: The next step forward [J].
Benjamin, RJ ;
Mintz, PD .
TRANSFUSION, 2005, 45 (12) :1832-1835
[3]   Bacterial detection of platelets: Current problems and possible resolutions [J].
Blajchman, MA ;
Beckers, EAM ;
Dickmeiss, E ;
Lin, L ;
Moore, G ;
Muylle, L .
TRANSFUSION MEDICINE REVIEWS, 2005, 19 (04) :259-272
[4]   Investigation of an isolate of Staphylococcus lugdunensis implicated in a platelet fatality:: a possible advantage of the use of an anaerobic bottle [J].
Brecher, Mark E. ;
Hay, Shauna N. .
TRANSFUSION, 2007, 47 (08) :1390-1394
[5]   Bacterial contamination of blood components [J].
Brecher, ME ;
Hay, SN .
CLINICAL MICROBIOLOGY REVIEWS, 2005, 18 (01) :195-+
[6]   Evaluation of a new generation of culture bottle using an automated bacterial culture system for detecting nine common contaminating organisms found in platelet components [J].
Brecher, ME ;
Heath, DG ;
Hay, SN ;
Rothenberg, SJ ;
Stutzman, LC .
TRANSFUSION, 2002, 42 (06) :774-779
[7]   Feasibility of implementing an automated culture system for bacteria screening in platelets in the blood bank routine [J].
Castro, E ;
Bueno, JL ;
Barea, L ;
González, R .
TRANSFUSION MEDICINE, 2005, 15 (03) :185-195
[8]   Effects of skin disinfection method, deviation bag, and bacterial screening on clinical safety of platelet transfusions in the Netherlands [J].
de Korte, D ;
Curvers, J ;
de Kort, WLAM ;
Hoekstra, T ;
van der Poel, CL ;
Beckers, EAM ;
Marcelis, JH .
TRANSFUSION, 2006, 46 (03) :476-485
[9]   Two novel real-time reverse transcriptase PCR assays for rapid detection of bacterial contamination in platelet concentrates [J].
Dreier, J ;
Störmer, M ;
Kleesiek, K .
JOURNAL OF CLINICAL MICROBIOLOGY, 2004, 42 (10) :4759-4764
[10]   Real-time polymerase chain reaction in transfusion medicine:: Applications for detection of bacterial contamination in blood products [J].
Dreier, Jens ;
Stoermer, Melanie ;
Kleesiek, Knut .
TRANSFUSION MEDICINE REVIEWS, 2007, 21 (03) :237-254