In vivo demonstration of cavitation potential of a mechanical heart valve

被引:25
|
作者
Dexter, EU
Aluri, S
Radcliffe, RR
Zhu, H
Carlson, DD
Heilman, TE
Chandran, KB
Richenbacher, WE
机构
[1] Univ Iowa, Dept Surg, Div Cardiothorac Surg, Iowa City, IA 52242 USA
[2] Univ Iowa, Dept Biomed Engn, Iowa City, IA 52242 USA
关键词
D O I
10.1097/00002480-199909000-00014
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Cavitation is implicated as the cause of pitting and erosion or: explanted mechanical heart valves that failed. Previous in vitro studies demonstrated transient negative pressure spikes upstream of mechanical heart valves at the instant of leaflet closure. When the magnitude of the transient negative pressure spike is below the vapor pressure of the fluid flowing across the mechanical valve, cavitation bubbles have been documented near the valve housing or occluder disc. To test for the presence of transient negative pressure spikes that are conducive to cavitation in vivo, we measured left atrial pressure at the valve orifice after mitral valve replacement. Mitral valves were replaced with 27 mm prostheses in 10 goats (50-60 kg), Control animals (Group 1, n = 5) received pericardial valves. Study animals (Group 2, n = 5) received bileaflet pyrolytic carbon valves. Pressure was recorded from a high frequency atrial transducer at hyperdynamic and hypodynamic states. Transient negative pressure spikes did not occur in any Group 1 animal. Transient negative pressure spikes below the vapor pressure of blood (-713 mm Hg) were recorded in four of five Group 2 animals at the hyperdynamic state: -900, -950, -800, -400, and -1,400 mm Hg (p = 0.048 Group 1 versus Group 2, Fisher's exact test). No cavitation potential exists in vivo after bioprosthetic valve implantation, Transient negative pressure spikes below the vapor pressure of blood occur in vivo at hyperdynamic physiologic states when this bileaflet pyrolytic carbon valve is implanted in the mitral position, These studies demonstrate the potential for cavitation with implanted mechanical valves in vivo.
引用
收藏
页码:436 / 441
页数:6
相关论文
共 50 条
  • [1] In vivo demonstration of cavitation potential of a mechanical heart valve
    Division of Cardiothoracic Surgery, Department of Surgery, University of Iowa, Iowa City, IA, United States
    不详
    不详
    ASAIO J., 5 (436-441):
  • [2] CAVITATION POTENTIAL OF MECHANICAL HEART-VALVE PROSTHESES
    GRAF, T
    FISCHER, H
    REUL, H
    RAU, G
    INTERNATIONAL JOURNAL OF ARTIFICIAL ORGANS, 1991, 14 (03): : 169 - 174
  • [3] Mechanical heart valve cavitation
    Johansen, P
    EXPERT REVIEW OF MEDICAL DEVICES, 2004, 1 (01) : 95 - 104
  • [4] Visualization of cavitation on mechanical heart valve
    He, Zhao-Ming
    Xi, Bao-Shu
    Zhu, Ke-Qin
    Zu, Pei-Zhen
    Zhongguo Shengwu Yixue Gongcheng Xuebao/Chinese Journal of Biomedical Engineering, 2002, 21 (04):
  • [5] Mechanical heart valve cavitation: Valve specific parameters
    Eichler, MJ
    Reul, HM
    INTERNATIONAL JOURNAL OF ARTIFICIAL ORGANS, 2004, 27 (10): : 855 - 867
  • [6] Observation of cavitation pits on a mechanical heart valve surface in an artificial heart used in in vivo testing
    Hwansung Lee
    Akihiko Homma
    Eisuke Tatsumi
    Yoshiyuki Taenaka
    Journal of Artificial Organs, 2009, 12 : 105 - 110
  • [7] Observation of cavitation pits on a mechanical heart valve surface in an artificial heart used in in vivo testing
    Lee, Hwansung
    Homma, Akihiko
    Tatsumi, Eisuke
    Taenaka, Yoshiyuki
    JOURNAL OF ARTIFICIAL ORGANS, 2009, 12 (02) : 105 - 110
  • [8] Indication of cavitation in mechanical heart valve patients
    Andersen, TS
    Johansen, P
    Paulsen, PK
    Nygaard, H
    Hasenkam, JM
    JOURNAL OF HEART VALVE DISEASE, 2003, 12 (06): : 790 - 796
  • [9] Observation of cavitation in a mechanical heart valve in a total artificial heart
    Lee, H
    Tsukiya, T
    Homma, A
    Kamimura, T
    Takewa, Y
    Nishinaka, T
    Tatsumi, E
    Taenaka, Y
    Takano, H
    Kitamura, S
    ASAIO JOURNAL, 2004, 50 (03) : 205 - 210
  • [10] Wavelet transforms in the analysis of mechanical heart valve cavitation
    Herbertson, LH
    Reddy, V
    Manning, KB
    Welz, JP
    Fontaine, AA
    Deutsch, S
    JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME, 2006, 128 (02): : 217 - 222