Radial Artery Applanation Tonometry for Continuous Noninvasive Cardiac Output Measurement: A Comparison With Intermittent Pulmonary Artery Thermodilution in Patients After Cardiothoracic Surgery

被引:33
作者
Wagner, Julia Y. [1 ]
Sarwari, Harun [1 ]
Schoen, Gerhard [2 ]
Kubik, Mathias [3 ,4 ]
Kluge, Stefan [3 ]
Reichenspurner, Hermann [4 ]
Reuter, Daniel A. [1 ]
Saugel, Bernd [1 ]
机构
[1] Univ Med Ctr Hamburg Eppendorf, Dept Anesthesiol, Ctr Anesthesiol & Intens Care Med, Hamburg, Germany
[2] Univ Med Ctr Hamburg Eppendorf, Dept Med Biometry & Epidemiol, Hamburg, Germany
[3] Univ Med Ctr Hamburg Eppendorf, Dept Intens Care Med, Hamburg, Germany
[4] Univ Heart Ctr Hamburg, Dept Cardiovasc Surg, Hamburg, Germany
关键词
cardiac output; critical care; hemodynamic monitoring; pulmonary artery catheter; T-Line; INTENSIVE-CARE-UNIT; BLOOD-PRESSURE; DEVICE; HEART; CATHETERIZATION; METAANALYSIS;
D O I
10.1097/CCM.0000000000000979
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Objectives: Radial artery applanation tonometry allows completely noninvasive continuous cardiac output estimation. The aim of the present study was to compare cardiac output measurements obtained with applanation tonometry (AT-CO) using the T-Line system (Tensys Medical, San Diego, CA) with cardiac output measured by intermittent pulmonary artery thermodilution using a pulmonary artery catheter (PAC-CO) with regard to accuracy, precision of agreement, and trending ability. Design: A prospective method comparison study. Setting: The study was conducted in a cardiosurgical ICU of a German university hospital. Patients: We performed cardiac output measurements in 50 patients after cardiothoracic surgery. Interventions: None. Measurements and Main Results: Three independent sets of three consecutive thermodilution measurements (i.e., PAC-CO) each were performed per patient, and AT-CO was measured simultaneously. The average of the three thermodilution cardiac output measurements was compared with the average of the corresponding three AT-CO values resulting in 150 paired cardiac output measurements. In 13 patients, cardiac output-modifying maneuvers performed for clinical reasons additionally allowed to evaluate trending ability. For statistical analysis, we used Bland-Altman analysis, the percentage error, four-quadrant plot, and concordance analysis. Mean PAC-CO was 4.71.2L/min and mean AT-CO was 4.9 +/- 1.1L/min. The mean of differences was -0.2L/min with 95% limits of agreement of -1.8 to + 1.4L/min. The percentage error was 34%. The concordance rate was 95%. Conclusions: Continuous cardiac output measurement using the noninvasive applanation tonometry technology is basically feasible in ICU patients after cardiothoracic surgery. The applanation tonometry technology provides cardiac output values with reasonable accuracy and precision of agreement compared with intermittent pulmonary artery thermodilution measurements in a clinical study setting and is able to reliably track cardiac output changes induced by cardiac output-modifying maneuvers.
引用
收藏
页码:1423 / 1428
页数:6
相关论文
共 41 条
  • [1] COMPARISON OF MEASUREMENTS OF CARDIAC-OUTPUT BY BIOIMPEDANCE AND THERMODILUTION IN SEVERELY ILL SURGICAL PATIENTS
    APPEL, PL
    KRAM, HB
    MACKABEE, J
    FLEMING, AW
    SHOEMAKER, WC
    [J]. CRITICAL CARE MEDICINE, 1986, 14 (11) : 933 - 935
  • [2] Comparing different methods of cardiac output determination: a call for consensus
    Bein, B.
    Renner, J.
    Scholz, J.
    Tonner, P. H.
    [J]. EUROPEAN JOURNAL OF ANAESTHESIOLOGY, 2006, 23 (08) : 710 - 710
  • [3] Continuous non-invasive monitoring improves blood pressure stability in upright position: randomized controlled trial
    Benes, Jan
    Simanova, Alena
    Tovarnicka, Tereza
    Sevcikova, Silvie
    Kletecka, Jakub
    Zatloukal, Jan
    Pradl, Richard
    Chytra, Ivan
    Kasal, Eduard
    [J]. JOURNAL OF CLINICAL MONITORING AND COMPUTING, 2015, 29 (01) : 11 - 17
  • [4] Agreement between methods of measurement with multiple observations per individual
    Bland, J. Martin
    Altman, Douglas G.
    [J]. JOURNAL OF BIOPHARMACEUTICAL STATISTICS, 2007, 17 (04) : 571 - 582
  • [5] Pulse contour cardiac output derived from non-invasive arterial pressure in cardiovascular disease
    Bogert, L. W. J.
    Wesseling, K. H.
    Schraa, O.
    Van Lieshout, E. J.
    de Mol, B. A. J. M.
    van Goudoever, J.
    Westerhof, B. E.
    van Lieshout, J. J.
    [J]. ANAESTHESIA, 2010, 65 (11) : 1119 - 1125
  • [6] Noninvasive Continuous Cardiac Output by the Nexfin Before and After Preload-Modifying Maneuvers: A Comparison with Intermittent Thermodilution Cardiac Output
    Bubenek-Turconi, Serban Ion
    Craciun, Mihaela
    Miclea, Ion
    Perel, Azriel
    [J]. ANESTHESIA AND ANALGESIA, 2013, 117 (02) : 366 - 372
  • [7] What is a fluid challenge?
    Cecconi, Maurizio
    Parsons, Anthony K.
    Rhodes, Andrew
    [J]. CURRENT OPINION IN CRITICAL CARE, 2011, 17 (03) : 290 - 295
  • [8] The effectiveness of right heart catheterization in the initial care of critically ill patients
    Connors, AF
    Speroff, T
    Dawson, NV
    Thomas, C
    Harrell, FE
    Wagner, D
    Desbiens, N
    Goldman, L
    Wu, AW
    Califf, RM
    Fulkerson, WJ
    Vidaillet, H
    Broste, S
    Bellamy, P
    Lynn, J
    Knaus, WA
    [J]. JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 1996, 276 (11): : 889 - 897
  • [9] A meta-analysis of studies using bias and precision statistics to compare cardiac output measurement techniques
    Critchley, LAH
    Critchley, JAJH
    [J]. JOURNAL OF CLINICAL MONITORING AND COMPUTING, 1999, 15 (02) : 85 - 91
  • [10] A Critical Review of the Ability of Continuous Cardiac Output Monitors to Measure Trends in Cardiac Output
    Critchley, Lester A.
    Lee, Anna
    Ho, Anthony M. -H.