Simulated Keratometry Versus Total Corneal Power by Ray Tracing: A Comparison in Prediction Accuracy of Intraocular Lens Power

被引:49
|
作者
Savini, Giacomo [1 ]
Hoffer, Kenneth J. [2 ,3 ]
Lomoriello, Domenico Schiano [1 ]
Ducoli, Pietro [1 ]
机构
[1] Fdn GB Bietti, IRCCS, Via Livenza 3, I-00198 Rome, Italy
[2] Univ Calif Los Angeles, Stein Eye Inst, Los Angeles, CA USA
[3] St Marys Eye Ctr, Santa Monica, CA USA
关键词
corneal power; intraocular lens power calculation; cataract surgery; TOPOGRAPHY; SYSTEM;
D O I
10.1097/ICO.0000000000001343
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: To investigate the relationship between corneal powers measured by simulated keratometry (Sim-K) and ray tracing and understand whether their difference influences intraocular lens (IOL) power calculation. Methods: In a first sample of healthy eyes, corneal curvature was measured using a rotating Scheimpflug camera (Sirius, CSO). Sim-K was obtained from anterior corneal curvature using the 1.3375 keratometric index. Ray tracing was performed through both corneal surfaces to calculate the total corneal power (TCP). The difference between Sim-K and TCP was correlated with various parameters. In a second sample of patients undergoing cataract surgery, IOL power was subsequently calculated using both Sim-K and TCP. Results: In the first sample (114 eyes), Sim-K (43.64+/-1.44 D) was higher than TCP (43.07+/-1.41 D, P, 0.0001); the difference ranged between 0.07 and 1.95 D and correlated with the anterior/posterior (A/P) ratio (r = 0.7292, P, 0.0001), which ranged between 1.10 and 1.30. In the second sample (107 eyes), the A/P ratio influenced the outcomes of the Holladay 1 and SRK/T, but not Haigis and Hoffer Q formulas. However, using TCP, which takes the A/P ratio into account, did not improve the prediction error of any formula. Conclusions: Sim-K provides a higher corneal power compared with TCP. This difference is not constant but depends on the A/P ratio and can influence the refractive outcome of IOL power calculation by theoretical formulas. However, TCP values do not improve the results of these formulas, as they were developed for keratometric values such as Sim-K.
引用
收藏
页码:1368 / 1372
页数:5
相关论文
共 50 条
  • [1] Prediction Accuracy of Total Keratometry Compared to Standard Keratometry Using Different Intraocular Lens Power Formulas
    Fabian, Ekkehard
    Wehner, Wolfram
    JOURNAL OF REFRACTIVE SURGERY, 2019, 35 (06) : 362 - 369
  • [2] Accuracy of Intraocular Lens Power Calculations Based on Total and Standard Keratometry
    Park, Se Young
    Choi, Jin Seok
    Pak, Kyu Hong
    Chung, Sung Kun
    Kwag, Joo Young
    JOURNAL OF THE KOREAN OPHTHALMOLOGICAL SOCIETY, 2020, 61 (11): : 1265 - 1272
  • [3] Comparison of intraocular lens power calculation formulas with and without total keratometry and ray tracing in patients with previous myopic SMILE
    Elotmani, Anouar Meziane
    Messerschmidt-Roth, Anke
    Nehme, Alexandra
    Mueller, Hans-Helge
    Sekundo, Walter
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2023, 49 (05): : 467 - 473
  • [4] Corneal ray tracing versus simulated keratometry for estimating corneal power changes after excimer laser surgery
    Savini, Giacomo
    Calossi, Antonio
    Camellin, Massimo
    Carones, Francesco
    Fantozzi, Marco
    Hoffer, Kenneth J.
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2014, 40 (07): : 1109 - 1115
  • [5] Total keratometry versus standard keratometry for intraocular lens power calculation in eyes with keratoconus
    Parra-Bernal, Cinthya
    Villasenor-Garcia, Rocio
    Fernandez-Munoz, Erika
    Castro-Monreal, Miguel
    Gonzalez-Salinas, Roberto
    INTERNATIONAL OPHTHALMOLOGY, 2024, 44 (01)
  • [6] Intraocular lens constant optimization in toric intraocular lens calculation using keratometry and total corneal power
    Liang, Jianheng
    Liu, Hui
    Zhou, Suowang
    Zhou, Lijing
    Qian, Zhuyun
    Jiang, Lihong
    Chen, Xu
    EUROPEAN JOURNAL OF OPHTHALMOLOGY, 2023, 33 (01) : 230 - 238
  • [7] Evaluation of total keratometry and its accuracy for intraocular lens power calculation in eyes after corneal refractive surgery
    Wang, Li
    Spektor, Tatyana
    de Souza, Rodrigo G.
    Koch, Douglas D.
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2019, 45 (10): : 1416 - 1421
  • [8] Comparison of corneal astigmatism and axis location in cataract patients measured by total corneal power, automated keratometry, and simulated keratometry
    Srivannaboon, Sabong
    Soeharnila
    Chirapapaisan, Chareenun
    Chonpimai, Pratuangsri
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2012, 38 (12): : 2088 - 2093
  • [9] Prediction accuracy of conventional and total keratometry for intraocular lens power calculation in femtosecond laser-assisted cataract surgery
    Soyoung Ryu
    Ikhyun Jun
    Tae-im Kim
    Kyoung Yul Seo
    Eung Kweon Kim
    Scientific Reports, 11
  • [10] Prediction accuracy of conventional and total keratometry for intraocular lens power calculation in femtosecond laser-assisted cataract surgery
    Ryu, Soyoung
    Jun, Ikhyun
    Kim, Tae-im
    Seo, Kyoung Yul
    Kim, Eung Kweon
    SCIENTIFIC REPORTS, 2021, 11 (01)