Effect of voxel size on the accuracy of 3D reconstructions with cone beam CT

被引:102
|
作者
Maret, D. [1 ,2 ]
Telmon, N. [1 ,3 ]
Peters, O. A. [4 ]
Lepage, B. [5 ]
Treil, J. [1 ]
Inglese, J. M. [6 ]
Peyre, A. [2 ]
Kahn, J. L. [7 ]
Sixou, M. [2 ,8 ]
机构
[1] Univ Toulouse 3, Lab Anthropol Mol & Imagerie Synt, CNRS, UMR 5288, F-31000 Toulouse, France
[2] Univ Toulouse 3, Fac Chirurg Dent, Ctr Hosp Univ, F-31000 Toulouse, France
[3] Hop Ramgueil, Serv Med Legale, Toulouse, France
[4] Univ Pacific, Arthur A Dugoni Sch Dent, Dept Endodont, San Francisco, CA USA
[5] Ctr Hosp Univ, Serv Epidemiol, Toulouse, France
[6] Carestream Hlth Inc, Dent Syst Grp, Marne La Vallee, France
[7] Inst Anat Normale Strasbourg, Strasbourg, France
[8] Univ Toulouse 3, MPDSB, Lab Univ LU 51, F-31000 Toulouse, France
关键词
cone-beam computed tomography; X-ray microtomography; three-dimensional imaging; MICRO-COMPUTED TOMOGRAPHY; AGE ESTIMATION; CANALS; MOLARS; IMAGES; FILES; CBCT;
D O I
10.1259/dmf/81804525
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Objectives: The various types of cone beam CT (CBCT) differ in several technical characteristics, notably their spatial resolution, which is defined by the acquisition voxel size. However, data are still lacking on the effects of voxel size on the metric accuracy of three-dimensional (3D) reconstructions. This study was designed to assess the effect of isotropic voxel size on the 3D reconstruction accuracy and reproducibility of CBCT data. Methods: The study sample comprised 70 teeth (from the Institut d'Anatomie Normale, Strasbourg, France). The teeth were scanned with a KODAK 9500 3D (R) CBCT (Carestream Health, Inc., Marne-la-Vallee, France), which has two voxel sizes: 200 mu m (CBCT 200 mu m group) and 300 mu m (CBCT 300 mu m group). These teeth had also been scanned with the KODAK 9000 3D (R) CBCT (Carestream Health, Inc.) (CBCT 76 mu m group) and the SCANCO Medical micro-CT XtremeCT (SCANCO Medical, Bruttisellen, Switzerland) (micro-CT 41 mu m group) considered as references. After semi-automatic segmentation with AMIRA (R) software (Visualization Sciences Group, Burlington, MA), tooth volumetric measurements were obtained. Results: The Bland-Altman method showed no difference in tooth volumes despite a slight underestimation for the CBCT 200 mu m and 300 mu m groups compared with the two reference groups. The underestimation was statistically significant for the volumetric measurements of the CBCT 300 mu m group relative to the two reference groups (Passing-Bablok method). Conclusions: CBCT is not only a tool that helps in diagnosis and detection but it has the complementary advantage of being a measuring instrument, the accuracy of which appears connected to the size of the voxels. Future applications of such measurements with CBCT are discussed. Dentomaxillofacial Radiology (2012) 41, 649-655. doi: 10.1259/dmf/81804525
引用
收藏
页码:649 / 655
页数:7
相关论文
共 50 条
  • [41] Accuracy of the anthropometric measurements of skeleton-ized skulls with corresponding measurements of their 3D reconstructions obtained by CT scanning
    Lorkiewicz-Muszynska, Dorota
    Kociemba, Wojciech
    Sroka, Alicja
    Kulczyk, Tomasz
    Zaba, Czeslaw
    Paprzycki, Wlodzimierz
    Przystanska, Agnieszka
    ANTHROPOLOGISCHER ANZEIGER, 2015, 72 (03) : 293 - 301
  • [42] Imaging Study of Pseudo-CT Synthesized From Cone-Beam CT Based on 3D CycleGAN in Radiotherapy
    Sun, Hongfei
    Fan, Rongbo
    Li, Chunying
    Lu, Zhengda
    Xie, Kai
    Ni, Xinye
    Yang, Jianhua
    FRONTIERS IN ONCOLOGY, 2021, 11
  • [43] Accuracy Assessment of EM3D App-Based 3D Facial Scanning Compared to Cone Beam Computed Tomography
    Barone, Selene
    Antonelli, Alessandro
    Salviati, Marianna
    Greco, Vincenzo
    Bennardo, Francesco
    Becker, Kathrin
    Giudice, Amerigo
    Simeone, Michele
    DENTISTRY JOURNAL, 2024, 12 (11)
  • [44] Effect of voxel size on detection of fenestration, dehiscence and furcation defects using cone-beam computed tomography
    Masoumeh Eftekhar
    Hanieh Kaviani
    Nina Rouzmeh
    Aitin Torabinia
    Alireza Akbarzadeh Baghban
    Oral Radiology, 2021, 37 : 677 - 686
  • [45] Using cone-beam CT as a low-dose 3D imaging technique for the extremities: initial experience in 50 subjects
    Huang, Ambrose J.
    Chang, Connie Y.
    Thomas, Bijoy J.
    MacMahon, Peter J.
    Palmer, William E.
    SKELETAL RADIOLOGY, 2015, 44 (06) : 797 - 809
  • [46] The sensitivity and accuracy of a cone beam CT in detecting the chorda tympani
    Hiraumi, Harukazu
    Suzuki, Ryo
    Yamamoto, Norio
    Sakamoto, Tatsunori
    Ito, Juichi
    EUROPEAN ARCHIVES OF OTO-RHINO-LARYNGOLOGY, 2016, 273 (04) : 873 - 877
  • [47] Age estimation by measuring maxillary canine pulp/tooth volume ratio on cone beam CT images with two different voxel sizes
    Adisen, Mehmet Zahit
    Keles, Aydan
    Yorubulut, Serap
    Nalcaci, Rana
    AUSTRALIAN JOURNAL OF FORENSIC SCIENCES, 2020, 52 (01) : 71 - 82
  • [48] New 3D Cone Beam CT Imaging Parameters to Assist the Dentist in Treating Patients with Osteogenesis Imperfecta
    Messineo, Daniela
    Luzzi, Valeria
    Pepe, Francesca
    Celli, Luca
    Turchetti, Arianna
    Zambrano, Anna
    Celli, Mauro
    Polimeni, Antonella
    Ierardo, Gaetano
    HEALTHCARE, 2020, 8 (04)
  • [49] Effect of the voxel size on the accuracy of endodontic length measurements using cone-beam computed tomography: A systematic review conducted according to the PRISMA guidelines and Cochrane Handbook for Systematic Reviews of Interventions
    Bhandi, Shilpa
    Ricks, Benjamin
    Patil, Shankargouda
    Awan, Kamran H.
    Licari, Frank W.
    Cicciu, Marco
    Minervini, Giuseppe
    DENTAL AND MEDICAL PROBLEMS, 2025, 62 (01) : 135 - 144
  • [50] Measurements on 3D models of human skulls derived from two different cone beam CT scanners
    Olivier J. C. van Vlijmen
    Frits A. Rangel
    Stefaan J. Bergé
    Ewald M. Bronkhorst
    Alfred G. Becking
    Anne Marie Kuijpers-Jagtman
    Clinical Oral Investigations, 2011, 15 : 721 - 727