Effect of voxel size on the accuracy of 3D reconstructions with cone beam CT

被引:102
|
作者
Maret, D. [1 ,2 ]
Telmon, N. [1 ,3 ]
Peters, O. A. [4 ]
Lepage, B. [5 ]
Treil, J. [1 ]
Inglese, J. M. [6 ]
Peyre, A. [2 ]
Kahn, J. L. [7 ]
Sixou, M. [2 ,8 ]
机构
[1] Univ Toulouse 3, Lab Anthropol Mol & Imagerie Synt, CNRS, UMR 5288, F-31000 Toulouse, France
[2] Univ Toulouse 3, Fac Chirurg Dent, Ctr Hosp Univ, F-31000 Toulouse, France
[3] Hop Ramgueil, Serv Med Legale, Toulouse, France
[4] Univ Pacific, Arthur A Dugoni Sch Dent, Dept Endodont, San Francisco, CA USA
[5] Ctr Hosp Univ, Serv Epidemiol, Toulouse, France
[6] Carestream Hlth Inc, Dent Syst Grp, Marne La Vallee, France
[7] Inst Anat Normale Strasbourg, Strasbourg, France
[8] Univ Toulouse 3, MPDSB, Lab Univ LU 51, F-31000 Toulouse, France
关键词
cone-beam computed tomography; X-ray microtomography; three-dimensional imaging; MICRO-COMPUTED TOMOGRAPHY; AGE ESTIMATION; CANALS; MOLARS; IMAGES; FILES; CBCT;
D O I
10.1259/dmf/81804525
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Objectives: The various types of cone beam CT (CBCT) differ in several technical characteristics, notably their spatial resolution, which is defined by the acquisition voxel size. However, data are still lacking on the effects of voxel size on the metric accuracy of three-dimensional (3D) reconstructions. This study was designed to assess the effect of isotropic voxel size on the 3D reconstruction accuracy and reproducibility of CBCT data. Methods: The study sample comprised 70 teeth (from the Institut d'Anatomie Normale, Strasbourg, France). The teeth were scanned with a KODAK 9500 3D (R) CBCT (Carestream Health, Inc., Marne-la-Vallee, France), which has two voxel sizes: 200 mu m (CBCT 200 mu m group) and 300 mu m (CBCT 300 mu m group). These teeth had also been scanned with the KODAK 9000 3D (R) CBCT (Carestream Health, Inc.) (CBCT 76 mu m group) and the SCANCO Medical micro-CT XtremeCT (SCANCO Medical, Bruttisellen, Switzerland) (micro-CT 41 mu m group) considered as references. After semi-automatic segmentation with AMIRA (R) software (Visualization Sciences Group, Burlington, MA), tooth volumetric measurements were obtained. Results: The Bland-Altman method showed no difference in tooth volumes despite a slight underestimation for the CBCT 200 mu m and 300 mu m groups compared with the two reference groups. The underestimation was statistically significant for the volumetric measurements of the CBCT 300 mu m group relative to the two reference groups (Passing-Bablok method). Conclusions: CBCT is not only a tool that helps in diagnosis and detection but it has the complementary advantage of being a measuring instrument, the accuracy of which appears connected to the size of the voxels. Future applications of such measurements with CBCT are discussed. Dentomaxillofacial Radiology (2012) 41, 649-655. doi: 10.1259/dmf/81804525
引用
收藏
页码:649 / 655
页数:7
相关论文
共 50 条
  • [21] Effect of voxel size on detection of fenestration, dehiscence and furcation defects using cone-beam computed tomography
    Eftekhar, Masoumeh
    Kaviani, Hanieh
    Rouzmeh, Nina
    Torabinia, Aitin
    Akbarzadeh Baghban, Alireza
    ORAL RADIOLOGY, 2021, 37 (04) : 677 - 686
  • [22] Accuracy and reliability of landmark-based, surface-based and voxel-based 3D cone-beam computed tomography superimposition methods
    Ghoneima, A.
    Cho, H.
    Farouk, K.
    Kula, K.
    ORTHODONTICS & CRANIOFACIAL RESEARCH, 2017, 20 (04) : 227 - 236
  • [23] Influence of Head Motion on the Accuracy of 3D Reconstruction with Cone-Beam CT: Landmark Identification Errors in Maxillofacial Surface Model
    Lee, Kyung-Min
    Song, Jin-Myoung
    Cho, Jin-Hyoung
    Hwang, Hyeon-Shik
    PLOS ONE, 2016, 11 (04):
  • [24] Accuracy and reproducibility of four cone beam computed tomography devices using 3D implant-planning software
    Stimmelmayr, M.
    Denk, K.
    Erdelt, K.
    Krennmair, G.
    Mansour, S.
    Beuer, F.
    Guethg, J-F.
    INTERNATIONAL JOURNAL OF COMPUTERIZED DENTISTRY, 2017, 20 (01) : 21 - 34
  • [25] Quantitative assessment of cone-beam CT system by 3D point spread function
    Chen, ZK
    Ning, RL
    Conover, D
    Yu, Y
    MEDICAL IMAGING 2004: PHYSICS OF MEDICAL IMAGING, PTS 1 AND 2, 2004, 5368 : 574 - 585
  • [26] 3D IN VIVO DOSIMETRY USING MEGAVOLTAGE CONE-BEAM CT AND EPID DOSIMETRY
    van Elmpt, Wouter
    Nusten, Sebastiaan
    Petit, Steven
    Munheer, Ben
    Lambin, Philippe
    Dekker, Andre
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2009, 73 (05): : 1580 - 1587
  • [27] Deep learning for detection and 3D segmentation of maxillofacial bone lesions in cone beam CT
    Talia Yeshua
    Shmuel Ladyzhensky
    Amal Abu-Nasser
    Ragda Abdalla-Aslan
    Tami Boharon
    Avital Itzhak-Pur
    Asher Alexander
    Akhilanand Chaurasia
    Adir Cohen
    Jacob Sosna
    Isaac Leichter
    Chen Nadler
    European Radiology, 2023, 33 : 7507 - 7518
  • [28] Maxillary sinus 3D segmentation and reconstruction from cone beam CT data sets
    Shi, Hongjian
    Scarfe, William C.
    Farman, Allan G.
    INTERNATIONAL JOURNAL OF COMPUTER ASSISTED RADIOLOGY AND SURGERY, 2006, 1 (02) : 83 - 89
  • [29] Deep learning for detection and 3D segmentation of maxillofacial bone lesions in cone beam CT
    Yeshua, Talia
    Ladyzhensky, Shmuel
    Abu-Nasser, Amal
    Abdalla-Aslan, Ragda
    Boharon, Tami
    Itzhak-Pur, Avital
    Alexander, Asher
    Chaurasia, Akhilanand
    Cohen, Adir
    Sosna, Jacob
    Leichter, Isaac
    Nadler, Chen
    EUROPEAN RADIOLOGY, 2023, 33 (11) : 7507 - 7518
  • [30] Maxillary Sinus 3D Segmentation and Reconstruction from Cone Beam CT Data Sets
    Hongjian Shi
    William C. Scarfe
    Allan G. Farman
    International Journal of Computer Assisted Radiology and Surgery, 2006, 1 : 83 - 89