Effect of voxel size on the accuracy of 3D reconstructions with cone beam CT

被引:102
|
作者
Maret, D. [1 ,2 ]
Telmon, N. [1 ,3 ]
Peters, O. A. [4 ]
Lepage, B. [5 ]
Treil, J. [1 ]
Inglese, J. M. [6 ]
Peyre, A. [2 ]
Kahn, J. L. [7 ]
Sixou, M. [2 ,8 ]
机构
[1] Univ Toulouse 3, Lab Anthropol Mol & Imagerie Synt, CNRS, UMR 5288, F-31000 Toulouse, France
[2] Univ Toulouse 3, Fac Chirurg Dent, Ctr Hosp Univ, F-31000 Toulouse, France
[3] Hop Ramgueil, Serv Med Legale, Toulouse, France
[4] Univ Pacific, Arthur A Dugoni Sch Dent, Dept Endodont, San Francisco, CA USA
[5] Ctr Hosp Univ, Serv Epidemiol, Toulouse, France
[6] Carestream Hlth Inc, Dent Syst Grp, Marne La Vallee, France
[7] Inst Anat Normale Strasbourg, Strasbourg, France
[8] Univ Toulouse 3, MPDSB, Lab Univ LU 51, F-31000 Toulouse, France
关键词
cone-beam computed tomography; X-ray microtomography; three-dimensional imaging; MICRO-COMPUTED TOMOGRAPHY; AGE ESTIMATION; CANALS; MOLARS; IMAGES; FILES; CBCT;
D O I
10.1259/dmf/81804525
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Objectives: The various types of cone beam CT (CBCT) differ in several technical characteristics, notably their spatial resolution, which is defined by the acquisition voxel size. However, data are still lacking on the effects of voxel size on the metric accuracy of three-dimensional (3D) reconstructions. This study was designed to assess the effect of isotropic voxel size on the 3D reconstruction accuracy and reproducibility of CBCT data. Methods: The study sample comprised 70 teeth (from the Institut d'Anatomie Normale, Strasbourg, France). The teeth were scanned with a KODAK 9500 3D (R) CBCT (Carestream Health, Inc., Marne-la-Vallee, France), which has two voxel sizes: 200 mu m (CBCT 200 mu m group) and 300 mu m (CBCT 300 mu m group). These teeth had also been scanned with the KODAK 9000 3D (R) CBCT (Carestream Health, Inc.) (CBCT 76 mu m group) and the SCANCO Medical micro-CT XtremeCT (SCANCO Medical, Bruttisellen, Switzerland) (micro-CT 41 mu m group) considered as references. After semi-automatic segmentation with AMIRA (R) software (Visualization Sciences Group, Burlington, MA), tooth volumetric measurements were obtained. Results: The Bland-Altman method showed no difference in tooth volumes despite a slight underestimation for the CBCT 200 mu m and 300 mu m groups compared with the two reference groups. The underestimation was statistically significant for the volumetric measurements of the CBCT 300 mu m group relative to the two reference groups (Passing-Bablok method). Conclusions: CBCT is not only a tool that helps in diagnosis and detection but it has the complementary advantage of being a measuring instrument, the accuracy of which appears connected to the size of the voxels. Future applications of such measurements with CBCT are discussed. Dentomaxillofacial Radiology (2012) 41, 649-655. doi: 10.1259/dmf/81804525
引用
收藏
页码:649 / 655
页数:7
相关论文
共 50 条
  • [1] Accuracy of 3D Reconstructions Based on Cone Beam Computed Tomography
    Maret, D.
    Molinier, F.
    Braga, J.
    Peters, O. A.
    Telmon, N.
    Treil, J.
    Inglese, J. M.
    Cossie, A.
    Kahn, J. L.
    Sixou, M.
    JOURNAL OF DENTAL RESEARCH, 2010, 89 (12) : 1465 - 1469
  • [2] Cutting voxel projector a new approach to construct 3D cone beam CT operator
    Kulvait, Vojtech
    Moosmann, Julian
    Rose, Georg
    JOURNAL OF COMPUTATIONAL SCIENCE, 2025, 87
  • [3] Effect of voxel size on accuracy of cone beam computed tomographye-aided assessment of periodontal furcation involvement
    Kamburoglu, Kivanc
    Eres, Gulden
    Akgun, Ceren
    Yeta, Elif Naz
    Gulen, Orhan
    Karacaoglu, Fatma
    ORAL SURGERY ORAL MEDICINE ORAL PATHOLOGY ORAL RADIOLOGY, 2015, 120 (05): : 644 - 650
  • [4] Influence of head positioning during cone- beam CT imaging on the accuracy of virtual 3D models
    van Eijnatten, Maureen
    Wolff, Jan
    Pauwels, Ruben
    Karhu, Kalle
    Hietanen, Ari
    Sarkissian, Henry der
    Koivisto, Juha H.
    DENTOMAXILLOFACIAL RADIOLOGY, 2022, 51 (07)
  • [5] Cervical vertebrae maturation index estimates on cone beam CT: 3D reconstructions vs sagittal sections
    Bonfim, Marco A. E.
    Costa, Andre L. F.
    Fuziy, Acacio
    Ximenez, Michel E. L.
    Cotrim-Ferreira, Flavio A.
    Ferreira-Santos, Rivea I.
    DENTOMAXILLOFACIAL RADIOLOGY, 2016, 45 (01)
  • [6] Soft tissue coverage on the segmentation accuracy of the 3D surface-rendered model from cone-beam CT
    Dusseldorp, J. K.
    Stamatakis, H. C.
    Ren, Y.
    CLINICAL ORAL INVESTIGATIONS, 2017, 21 (03) : 921 - 930
  • [7] Comparison of the Accuracy of 3-dimensional Cone-beam Computed Tomography and Micro-Computed Tomography Reconstructions by Using Different Voxel Sizes
    Maret, Delphine
    Peters, Ove A.
    Galibourg, Antoine
    Dumoncel, Jean
    Esclassan, Remi
    Kahn, Jean-Luc
    Sixou, Michel
    Telmon, Norbert
    JOURNAL OF ENDODONTICS, 2014, 40 (09) : 1321 - 1326
  • [8] kVp, mA, and voxel size effect on 3D voxel-based superimposition
    Eliliwi, Manhal
    Bazina, Mohamed
    Palomo, Juan Martin
    ANGLE ORTHODONTIST, 2020, 90 (02) : 269 - 277
  • [9] Accuracy of detecting vertical root fractures in non-root filled teeth using cone beam computed tomography: effect of voxel size and fracture width
    Guo, X. L.
    Li, G.
    Zheng, J. Q.
    Ma, R. H.
    Liu, F. C.
    Yuan, F. S.
    Lyu, P. J.
    Guo, Y. J.
    Yin, S.
    INTERNATIONAL ENDODONTIC JOURNAL, 2019, 52 (06) : 887 - 898
  • [10] Projection-based improvement of 3D reconstructions from motion-impaired dental cone beam CT data
    Niebler, Stefan
    Schoemer, Elmar
    Tjaden, Henning
    Schwanecke, Ulrich
    Schulze, Ralf
    MEDICAL PHYSICS, 2019, 46 (10) : 4470 - 4480