Preconcentration, Speciation, and Determination of Mercury by Solid Phase Extraction with Cold Vapor Atomic Absorption Spectrometry

被引:27
作者
Turker, Ali Rehber [1 ]
Cabuk, Dilek [1 ]
Yalcinkaya, Ozcan [1 ]
机构
[1] Gazi Univ, Fac Sci, Dept Chem, TR-06500 Ankara, Turkey
关键词
Cold vapor atomic absorption spectrometry; Mercury; Methyl mercury; Solid phase extraction; Speciation; PERFORMANCE LIQUID-CHROMATOGRAPHY; METHYL MERCURY; INORGANIC MERCURY; ONLINE SPECIATION; WATER SAMPLES; FISH; FLUORESCENCE; AAS; METHYLMERCURY; DIGESTION;
D O I
10.1080/00032719.2012.753608
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
In this study, inorganic mercury [iHg (Hg2+)] and monomethylmercury [MeHg (CH3Hg+)] ions have been preconcentrated and determined by a column solid phase extraction method. Cold vapor atomic absorption spectrometry was used for the determination of mercury species. Optimum retention and elution parameters were determined for both mercury species separately. For this purpose, the effect of pH, flow rate and volume of sample solution, type, and concentration of eluent on the recovery of mercury species were investigated. Effects of possible interfering ions were also studied. Optimum values of flow rate, pH, and volume of sample solution were found to be 3mL min1, 4.0 and 50mL, respectively, for both iHg and MeHg ions. Although the both species were retained at pH 4, the elution could be performed only with different eluents. While MeHg ions were eluted with 10mL of 0.1mol/L HCl solution, iHg ions were eluted with 10mL of 0.2molL1 thioureasolution in 3molL1HCl. Limits of detection for iHg and MeHg were 0.44 mu gL1 and 0.56 mu gL1, respectively. To validate the proposed speciation and/or preconcentration method, a certified reference material (ERM-CE464) was analyzed and MeHg was determined with a relative error of 7.3%. The accuracy was also checked by analyzing spiked water and fish samples for both species.
引用
收藏
页码:1155 / 1170
页数:16
相关论文
共 50 条
  • [31] Sensitive Mercury Speciation Analysis in Water by High-Performance Liquid Chromatography-Atomic Fluorescence Spectrometry Coupling with Solid-Phase Extraction
    Chen, Dongyang
    Lu, Lan
    Zhang, Hao
    Lu, Bing
    Feng, Jiali
    Zeng, Dong
    ANALYTICAL SCIENCES, 2021, 37 (09) : 1235 - 1240
  • [32] DETERMINATION OF MERCURY IN URINE BY COLD VAPOR ATOMIC-ABSORPTION SPECTROMETRY
    LIVARDJANI, F
    HEIMBURGER, R
    LUGNIER, AA
    JAEGER, A
    ANALUSIS, 1994, 22 (07) : 365 - 368
  • [33] Highly selective and sensitive preconcentration of mercury ion and determination by cold vapor atomic absorption spectroscopy
    Ghaedi, M
    Fathi, MR
    Shokrollahi, A
    Shajarat, F
    ANALYTICAL LETTERS, 2006, 39 (06) : 1171 - 1185
  • [34] On-line preconcentration and determination of mercury in biological and environmental samples by cold vapor-atomic absorption spectrometry
    Ferrua, N.
    Cerutti, S.
    Salonia, J. A.
    Olsina, R. A.
    Martinez, L. D.
    JOURNAL OF HAZARDOUS MATERIALS, 2007, 141 (03) : 693 - 699
  • [35] Total mercury determination in different tissues of broiler chicken by using cloud point extraction and cold vapor atomic absorption spectrometry
    Shah, A. Q.
    Kazi, T. G.
    Baig, J. A.
    Afridi, H. I.
    Kandhro, G. A.
    Arain, M. B.
    Kolachi, N. F.
    Wadhwa, S. K.
    FOOD AND CHEMICAL TOXICOLOGY, 2010, 48 (01) : 65 - 69
  • [36] Study on the Solid Sorbent Tube for Capturing Mercury in the Workplace Air and Determination by Cold Vapor Atomic Absorption Spectrometry
    Huang Zhen-nong
    Sun Yi
    Ruan Xiao-lin
    Wu Bang-hua
    Zhang Ai-hua
    Huang Jun-yi
    Huang Yan-ling
    Huang Han-lin
    SPECTROSCOPY AND SPECTRAL ANALYSIS, 2014, 34 (05) : 1412 - 1415
  • [37] Use of Ni/NixB Nanoparticles as a Novel Adsorbent for the Preconcentration of Mercury Species prior to Cold Vapor-Atomic Fluorescence Spectrometric Determination
    Yayayuruk, Onur
    Henden, Emur
    ANALYTICAL SCIENCES, 2016, 32 (08) : 867 - 873
  • [38] Mercury speciation by coupling cold vapour atomic absorption spectrometry with flow injection on-line preconcentration and liquid chromatographic separation
    Xuefeng Yin
    Wolfgang Frech
    Erwin Hoffmann
    C. Lüdke
    Jochen Skole
    Fresenius' Journal of Analytical Chemistry, 1998, 361 : 761 - 766
  • [39] MICROWAVE DISSOLUTION FOR THE DETERMINATION OF MERCURY IN FISH BY COLD VAPOR ATOMIC-ABSORPTION SPECTROMETRY
    NAVARRO, M
    LOPEZ, MC
    LOPEZ, H
    SANCHEZ, M
    ANALYTICA CHIMICA ACTA, 1992, 257 (01) : 155 - 158
  • [40] DETERMINATION OF MERCURY IN SELENIUM METAL USING COLD VAPOR ATOMIC-ABSORPTION SPECTROMETRY
    SZMYD, E
    BARANOWSKA, I