Analog receive signal processing for magnetic particle imaging

被引:55
|
作者
Graeser, Matthias [1 ]
Knopp, Tobias [1 ]
Gruettner, Mandy [1 ]
Sattel, Timo F. [1 ]
Buzug, Thorsten M. [1 ]
机构
[1] Med Univ Lubeck, Inst Med Engn, D-23562 Lubeck, Germany
关键词
magnetic particle imaging; magnetic particle spectroscopy; signal processing; RESOLUTION;
D O I
10.1118/1.4794482
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: Magnetic particle imaging (MPI) applies oscillating magnetic fields to determine the distribution of magnetic nanoparticles in vivo. Using a receive coil, the change of the particle magnetization can be detected. However, the signal induced by the nanoparticles is superimposed by the direct feedthrough interference of the sinusoidal excitation field, which couples into the receive coils. As the latter is several magnitudes higher, the extraction of the particle signal from the excitation signal is a challenging task. Methods: One way to remove the interfering signal is to suppress the excitation signal by means of a band-stop filter. However, this technique removes parts of the desired particle signal, which are essential for direct reconstruction of the particle concentration. A way to recover the entire particle signal is to cancel out the excitation signal by coupling a matching cancellation signal into the receive chain. However, the suppression rates that can be achieved by signal cancellation are not as high as with the filtering method, which limits the sensitivity of this method. In order to unite the advantages of both methods, in this work the authors propose to combine the filtering and the cancellation technique. All methods were compared by measuring 10 mu l Resovist, in the same field generator only switching the signal processing parts. Results: The reconstructed time signals of the three methods, show the advantage of the proposed combination of filtering and cancellation. The method preserves the fundamental frequency and is able to detect the tracer signal at its full bandwidth even for low concentrations. Conclusions: By recovering the full particle signal the SNR can be improved and errors in the x-space reconstruction are prevented. The authors show that the combined method provides this full particle signal and makes it possible to improve image quality. (C) 2013 American Association of Physicists in Medicine. [http://dx.doi.org/10.1118/1.4794482]
引用
收藏
页数:9
相关论文
共 50 条
  • [21] Improvement of SNR in magnetic particle imaging based on magnetization signal generated by external vibration of magnetic nanoparticle
    Urushibata S.
    Ishihara Y.
    Transactions of Japanese Society for Medical and Biological Engineering, 2019, 57 (01): : 8 - 14
  • [22] Analog signal processing with nonlinear nonlocal flat optics
    de Ceglia, Domenico
    De Angelis, Costantino
    2024 24TH INTERNATIONAL CONFERENCE ON TRANSPARENT OPTICAL NETWORKS, ICTON 2024, 2024,
  • [23] Influence of signal bandwidth and phase delay on complex susceptibility based magnetic particle imaging
    Jiang, Tao
    Pi, Shiqiang
    Shi, Jiangshan
    Zhang, Pu
    Liu, Wenzhong
    Cheng, Jingjing
    MEASUREMENT SCIENCE AND TECHNOLOGY, 2019, 30 (11)
  • [24] Combining magnetic particle imaging and magnetic fluid hyperthermia in a theranostic platform
    Hensley, Daniel
    Tay, Zhi Wei
    Dhavalikar, Rohan
    Zheng, Bo
    Goodwill, Patrick
    Rinaldi, Carlos
    Conolly, Steven
    PHYSICS IN MEDICINE AND BIOLOGY, 2017, 62 (09) : 3483 - 3500
  • [25] Magnetic Particle Imaging: In vitro Signal Analysis and Lumen Quantification of 21 Endovascular Stents
    Wegner, Franz
    von Gladiss, Anselm
    Haegele, Julian
    Grzyska, Ulrike
    Sieren, Malte Maria
    Stahlberg, Erik
    Oechtering, Thekla Helene
    Luedtke-Buzug, Kerstin
    Barkhausen, Joerg
    Buzug, Thorsten M.
    Friedrich, Thomas
    INTERNATIONAL JOURNAL OF NANOMEDICINE, 2021, 16 : 213 - 221
  • [26] Magnetic Particle Imaging in Neurosurgery
    Meola, Antonio
    Rao, Jianghong
    Chaudhary, Navjot
    Song, Guosheng
    Zheng, Xianchuang
    Chang, Steven D.
    WORLD NEUROSURGERY, 2019, 125 : 261 - 270
  • [27] A Spectrometer for Magnetic Particle Imaging
    Biederer, S.
    Sattel, T.
    Knopp, T.
    Luedtke-Buzug, K.
    Gleich, B.
    Weizenecker, J.
    Borgert, J.
    Buzug, T. M.
    4TH EUROPEAN CONFERENCE OF THE INTERNATIONAL FEDERATION FOR MEDICAL AND BIOLOGICAL ENGINEERING, 2009, 22 (1-3): : 2313 - 2316
  • [28] Narrowband Magnetic Particle Imaging
    Goodwill, Patrick W.
    Scott, Greig C.
    Stang, Pascal P.
    Conolly, Steven M.
    IEEE TRANSACTIONS ON MEDICAL IMAGING, 2009, 28 (08) : 1231 - 1237
  • [29] Demodulation signal processing in multiphoton imaging
    Fisher, W
    Wachter, E
    Piston, D
    MULTIPHOTON MICROSCOPY IN THE BIOMEDICAL SCIENCES II, 2002, 4620 : 9 - 13
  • [30] Magnetic Particle Imaging (MPI)
    Haegele, J.
    Sattel, T.
    Erbe, M.
    Luedtke-Buzug, K.
    Taupitz, M.
    Borgert, J.
    Buzug, T. M.
    Barkhausen, J.
    Vogt, F. M.
    ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 2012, 184 (05): : 420 - 426