Analog receive signal processing for magnetic particle imaging

被引:55
|
作者
Graeser, Matthias [1 ]
Knopp, Tobias [1 ]
Gruettner, Mandy [1 ]
Sattel, Timo F. [1 ]
Buzug, Thorsten M. [1 ]
机构
[1] Med Univ Lubeck, Inst Med Engn, D-23562 Lubeck, Germany
关键词
magnetic particle imaging; magnetic particle spectroscopy; signal processing; RESOLUTION;
D O I
10.1118/1.4794482
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: Magnetic particle imaging (MPI) applies oscillating magnetic fields to determine the distribution of magnetic nanoparticles in vivo. Using a receive coil, the change of the particle magnetization can be detected. However, the signal induced by the nanoparticles is superimposed by the direct feedthrough interference of the sinusoidal excitation field, which couples into the receive coils. As the latter is several magnitudes higher, the extraction of the particle signal from the excitation signal is a challenging task. Methods: One way to remove the interfering signal is to suppress the excitation signal by means of a band-stop filter. However, this technique removes parts of the desired particle signal, which are essential for direct reconstruction of the particle concentration. A way to recover the entire particle signal is to cancel out the excitation signal by coupling a matching cancellation signal into the receive chain. However, the suppression rates that can be achieved by signal cancellation are not as high as with the filtering method, which limits the sensitivity of this method. In order to unite the advantages of both methods, in this work the authors propose to combine the filtering and the cancellation technique. All methods were compared by measuring 10 mu l Resovist, in the same field generator only switching the signal processing parts. Results: The reconstructed time signals of the three methods, show the advantage of the proposed combination of filtering and cancellation. The method preserves the fundamental frequency and is able to detect the tracer signal at its full bandwidth even for low concentrations. Conclusions: By recovering the full particle signal the SNR can be improved and errors in the x-space reconstruction are prevented. The authors show that the combined method provides this full particle signal and makes it possible to improve image quality. (C) 2013 American Association of Physicists in Medicine. [http://dx.doi.org/10.1118/1.4794482]
引用
收藏
页数:9
相关论文
共 50 条
  • [1] RECEIVE COIL ARRAY FOR MAGNETIC PARTICLE IMAGING
    Knopp, Tobias
    Sattel, Timo F.
    Biederer, Sven
    Weizenecker, Juergen
    Gleich, Bernhard
    Borgert, Joern
    Buzug, Thorsten M.
    2011 8TH IEEE INTERNATIONAL SYMPOSIUM ON BIOMEDICAL IMAGING: FROM NANO TO MACRO, 2011, : 1666 - 1669
  • [2] Analog filters for Enhanced Signal Reception of Magnetic Particle Imaging (MPI) Scanner
    Irfan, M.
    Mossa, H.
    Dogan, N.
    TIP TEKNOLOJILERI KONGRESI (TIPTEKNO'21), 2021,
  • [3] The hardware, tracer, and signal processing methods of magnetic particle imaging: A review
    Davida, Angga
    Basari, Basari
    JOURNAL OF APPLIED PHYSICS, 2024, 136 (22)
  • [4] Magnetic particle imaging: kinetics of the intravascular signal in vivo
    Haegele, Julian
    Duschka, Robert L.
    Graeser, Matthias
    Schaecke, Catharina
    Panagiotopoulos, Nikolaos
    Luedtke-Buzug, Kerstin
    Buzug, Thorsten M.
    Barkhausen, Joerg
    Vogt, Florian M.
    INTERNATIONAL JOURNAL OF NANOMEDICINE, 2014, 9 : 4203 - 4209
  • [5] Imaging and quantification of magnetic nanoparticles: Comparison of magnetic resonance imaging and magnetic particle imaging
    Paysen, Hendrik
    Loewa, Norbert
    Weber, Karol
    Kosch, Olaf
    Wells, James
    Schaeffter, Tobias
    Wiekhorst, Frank
    JOURNAL OF MAGNETISM AND MAGNETIC MATERIALS, 2019, 475 : 382 - 388
  • [6] Magnetic Nanoparticles in Macrophages and Cancer Cells Exhibit Different Signal Behavior on Magnetic Particle Imaging
    Suzuka, Hisaaki
    Mimura, Atsushi
    Inaoka, Yoshimi
    Murase, Kenya
    JOURNAL OF NANOSCIENCE AND NANOTECHNOLOGY, 2019, 19 (11) : 6857 - 6865
  • [7] Signal-to-noise ratio optimized image reconstruction technique for magnetic particle imaging
    Bozkurt, Ecem
    Saritas, Emine Uliku
    JOURNAL OF THE FACULTY OF ENGINEERING AND ARCHITECTURE OF GAZI UNIVERSITY, 2017, 32 (03): : 999 - 1013
  • [8] Analog Photonic Fractional Signal Processing
    Cuadrado-Laborde, Christian
    Poveda-Wong, Luis
    Carrascosa, Antonio
    Cruz, Jose L.
    Diez, Antonio
    Andres, Miguel V.
    PROGRESS IN OPTICS, VOL 63, 2018, 63 : 93 - 178
  • [9] Frequency-selective signal enhancement by a passive dual coil resonator for magnetic particle imaging
    Pantke, Dennis
    Mueller, Florian
    Reinartz, Sebastian
    Philipps, Jonas
    Dadfar, Seyed Mohammadali
    Peters, Maximilian
    Franke, Jochen
    Schrank, Franziska
    Kiessling, Fabian
    Schulz, Volkmar
    PHYSICS IN MEDICINE AND BIOLOGY, 2022, 67 (11):
  • [10] Experimental and simulation studies on the behavior of signal harmonics in magnetic particle imaging
    Murase K.
    Konishi T.
    Takeuchi Y.
    Takata H.
    Saito S.
    Radiological Physics and Technology, 2013, 6 (2) : 399 - 414