Comparison of radiation dose and image quality from single-energy and dual-energy CT examinations in the same patients screened for hepatocellular carcinoma

被引:52
作者
Purysko, A. S. [1 ]
Primak, A. N. [2 ]
Baker, M. E. [1 ]
Obuchowski, N. A. [3 ]
Remer, E. M. [1 ]
John, B. [4 ]
Herts, B. R. [1 ]
机构
[1] Cleveland Clin, Imaging Inst, Abdominal Imaging Sect, Cleveland, OH 44195 USA
[2] Siemens Med Solut USA Inc, Malvern, PA 19355 USA
[3] Cleveland Clin, Imaging Inst, Quantitat Hlth Sci, Cleveland, OH 44195 USA
[4] Cleveland Clin, Inst Digest Dis, Dept Gastroenterol & Hepatol, Cleveland, OH 44195 USA
关键词
D O I
10.1016/j.crad.2014.08.021
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
AIM: To compare radiation dose surrogates [volume CT dose index (CTDIvol), dose-length product (DLP), size-specific dose estimate (SSDE), and effective dose] and image noise in a cohort of patients undergoing hepatocellular carcinoma screening who underwent both single-energy CT (SECT) and dual-energy CT (DECT). MATERIALS AND METHODS: In this institutional review board-approved, Health Insurance Portability and Accountability Act-compliant retrospective study, 74 adults (mean age 59.5 years) underwent 64 section SECT (120 kVp and weight-based reference mAs) and 128 section dual-source DECT (100/Sn 140 kVp and CTDIvol, adjusted to match the CTDIvol of the SECT protocol) on different occasions. Noise levels were measured in the liver, inferior vena cava (IVC), retroperitoneal (RP) fat, and aorta. Generalized linear models were constructed to compare dose and noise, adjusting for effective diameter. RESULTS: The total DLP (1371.11 mGy-cm, SD = 527.91) and effective dose (20.57 mSv, SD = 7.92) with SECT were significantly higher than the DLP (864.84 mGy-cm, SD = 322.10) and effective dose (12.97 mSv, SD = 4.83) with DECT (p < 0.001). The differences between SECT and DECT increased as the patient's effective diameter increased (p < 0.001). Noise levels in the liver (22.4 versus 21.9 HU), IVC (22.3 versus 23.4 HU), and RP fat (23.5 versus 23 HU) were similar for DECT and SECT (p > 0.05) but were significantly lower in the aorta for DECT (25.3 versus 26.4 HU; p = 0.006). CONCLUSION: DECT imaging of the abdomen can achieve noise levels comparable to those seen with SECT imaging without a dose penalty to patients. (C) 2014 The Royal College of Radiologists. Published by Elsevier Ltd. All rights reserved.
引用
收藏
页码:E538 / E544
页数:7
相关论文
共 20 条
[1]   ENERGY-SELECTIVE RECONSTRUCTIONS IN X-RAY COMPUTERIZED TOMOGRAPHY [J].
ALVAREZ, RE ;
MACOVSKI, A .
PHYSICS IN MEDICINE AND BIOLOGY, 1976, 21 (05) :733-744
[2]   Virtual unenhanced second generation dual-source CT of the liver: Is it time to discard the conventional unenhanced phase? [J].
Barrett, T. ;
Bowden, D. J. ;
Shaida, N. ;
Godfrey, E. M. ;
Taylor, A. ;
Lomas, D. J. ;
Shaw, A. S. .
EUROPEAN JOURNAL OF RADIOLOGY, 2012, 81 (07) :1438-1445
[3]  
Boone J.M., 2011, SIZE SPECIFIC DOSE E
[4]   Second-Generation Dual-Energy Computed Tomography of the Abdomen: Radiation Dose Comparison With 64-and 128-Row Single-Energy Acquisition [J].
De Cecco, Carlo Nicola ;
Darnell, Anna ;
Macias, Napoleon ;
Ramon Ayuso, Juan ;
Rodriguez, Sonia ;
Rimola, Jordi ;
Pages, Mario ;
Garcia-Criado, Angeles ;
Rengo, Marco ;
Muscogiuri, Giuseppe ;
Laghi, Andrea ;
Ayuso, Carmen .
JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2013, 37 (04) :543-546
[5]   Virtual Unenhanced Images of the Abdomen With Second-Generation Dual-Source Dual-Energy Computed Tomography Image Quality and Liver Lesion Detection [J].
De Cecco, Carlo Nicola ;
Darnell, Anna ;
Macias, Napoleon ;
Ramon Ayuso, Juan ;
Rodriguez, Sonia ;
Rimola, Jordi ;
Pages, Mario ;
Garcia-Criado, Angeles ;
Rengo, Marco ;
Laghi, Andrea ;
Ayuso, Carmen .
INVESTIGATIVE RADIOLOGY, 2013, 48 (01) :1-9
[6]   Dual energy CT (DECT) of the liver: conventional versus virtual unenhanced images [J].
De Cecco, Carlo Nicola ;
Buffa, Vitaliano ;
Fedeli, Stefano ;
Luzietti, Monica ;
Vallone, Andrea ;
Ruopoli, Roberto ;
Miele, Vittorio ;
Rengo, Marco ;
Paolantonio, Pasquale ;
Enrici, Michelangelo Maurizi ;
Laghi, Andrea ;
David, Vincenzo .
EUROPEAN RADIOLOGY, 2010, 20 (12) :2870-2875
[7]   Quantification of liver iron content with CT-added value of dual-energy [J].
Fischer, Michael A. ;
Reiner, Caecilia S. ;
Raptis, Dimitri ;
Donati, Olivio ;
Goetti, Robert ;
Clavien, Pierre-Alain ;
Alkadhi, Hatem .
EUROPEAN RADIOLOGY, 2011, 21 (08) :1727-1732
[8]   Quantification of Liver Fat in the Presence of Iron and Iodine An Ex-Vivo Dual-Energy CT Study [J].
Fischer, Michael A. ;
Gnannt, Ralph ;
Raptis, Dimitri ;
Reiner, Caecilia S. ;
Clavien, Pierre-Alain ;
Schmidt, Bernhard ;
Leschka, Sebastian ;
Alkadhi, Hatem ;
Goetti, Robert .
INVESTIGATIVE RADIOLOGY, 2011, 46 (06) :351-358
[9]   Dual-Energy CT: Radiation Dose Aspects [J].
Henzler, Thomas ;
Fink, Christian ;
Schoenberg, Stefan O. ;
Schoepf, U. Joseph .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2012, 199 (05) :S16-S25
[10]   Dual-Energy CT Applications in the Abdomen [J].
Heye, Tobias ;
Nelson, Rendon C. ;
Ho, Lisa M. ;
Marin, Daniele ;
Boll, Daniel T. .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2012, 199 (05) :S64-S70