CLINICAL FACTORS AFFECTING THE ACCURACY OF GUIDED IMPLANT SURGERY-A SYSTEMATIC REVIEW AND META-ANALYSIS

被引:148
作者
Zhou, Wenjuan [1 ,2 ,3 ]
Liu, Zhonghao [1 ]
Song, Liansheng [2 ]
Kuo, Chia-Ling [4 ]
Shafer, David M. [2 ]
机构
[1] Binzhou Med Univ, Yantai Stomatol Hosp, Dept Implant Dent, Yantai, Peoples R China
[2] UConn Sch Dent Med, Div Oral & Maxillofacial Surg, 263 Farmington Ave, Farmington, CT 06030 USA
[3] Med Univ Vienna, Univ Clin Dent, Competent Ctr Periodontal Res, Div Conservat Dent & Periodontol, Vienna, Austria
[4] UConn Hlth, CT Inst Clin & Translat Sci, Farmington, CT USA
关键词
Dental implants; Computer-assisted; Guided surgery; Surgical guides; Accuracy; CONE-BEAM CT; STEREOLITHOGRAPHIC SURGICAL TEMPLATES; COMPUTED-TOMOGRAPHY; DENTAL IMPLANTS; PLACEMENT; COMPLICATIONS; RELIABILITY; NAVIGATION; POSITIONS; DEVIATION;
D O I
10.1016/j.jebdp.2017.07.007
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Objectives To systematically review the current dental literature regarding clinical accuracy of guided implant surgery and to analyze the involved clinical factors. Material and Methods PubMed and Cochrane Central Register of Controlled Trials were searched. Meta-analysis and meta-regression analysis were performed. Clinical studies with the following outcome measurements were included: (1) angle deviation, (2) deviation at the entry point, and (3) deviation at the apex. The involved clinical factors were further evaluated. Results Fourteen clinical studies from 1951 articles initially identified met the inclusion criteria. Meta-regression analysis revealed a mean deviation at the entry point of 1.25 mm (95% confidence interval [CI]: 1.22-1.29), 1.57 mm (95% CI: 1.53-1.62) at the apex, and 4.1 degrees in angle (95% CI: 3.97-4.23). A statistically significant difference (P<.001) was observed in angular deviations between the maxilla and mandible. Partially guided surgery showed a statistically significant greater deviation in angle (P<. 001), at the entry point (P<. 001), and at the apex (P<. 001) compared with totally guided surgery. The outcome of guided surgery with flapless approach indicated significantly more accuracy in angle (P<. 001), at the entry point (P<.001), and at apex (P<.001). Significant differences were observed in angular deviation based on the use of fixation screw (P<. 001). Conclusions The position of guide, guide fixation, type of guide, and flap approach could influence the accuracy of computer-aided implant surgery. A totally guided system using fixation screws with a flapless protocol demonstrated the greatest accuracy. Future clinical research should use a standardized measurement technique for improved accuracy.
引用
收藏
页码:28 / 40
页数:13
相关论文
共 50 条
  • [21] Narrative review regarding the applicability, accuracy, and clinical outcome of flapless implant surgery with or without computer guidance
    Naeini, Emitis Natali
    Atashkadeh, Mandana
    De Bruyn, Hugo
    D'Haese, Jan
    CLINICAL IMPLANT DENTISTRY AND RELATED RESEARCH, 2020, 22 (04) : 454 - 467
  • [22] The Accuracy of Dental Implant Placement With Different Methods of Computer-Assisted Implant Surgery: A Network Meta-Analysis of Clinical Studies
    Mahardawi, Basel
    Jiaranuchart, Sirimanas
    Arunjaroensuk, Sirida
    Dhanesuan, Kanit
    Mattheos, Nikos
    Pimkhaokham, Atiphan
    CLINICAL ORAL IMPLANTS RESEARCH, 2025, 36 (01) : 1 - 16
  • [23] Accuracy of freehand surgery, static and dynamic computer assisted surgery on zygomatic implant placement: A systematic review and meta-analyses
    Traboulsi-Garet, Bassel
    Jorba-Garcia, Adria
    Bara-Casaus, Javier
    Camps-Font, Octavi
    Valmaseda-Castellon, Eduard
    Figueiredo, Rui
    Sanchez-Garces, Angels
    JOURNAL OF CRANIO-MAXILLOFACIAL SURGERY, 2025, 53 (04) : 301 - 311
  • [24] Implant survival rates, marginal bone level changes, and complications in full-mouth rehabilitation with flapless computer-guided surgery: a systematic review and meta-analysis
    Moraschini, V.
    Velloso, G.
    Luz, D.
    Porto Barboza, E.
    INTERNATIONAL JOURNAL OF ORAL AND MAXILLOFACIAL SURGERY, 2015, 44 (07) : 892 - 901
  • [25] The accuracy of static computer-aided implant surgery: A systematic review and meta-analysis
    Tahmaseb, Ali
    Wu, Viviane
    Wismeijer, Daniel
    Coucke, Wim
    Evans, Christopher
    CLINICAL ORAL IMPLANTS RESEARCH, 2018, 29 : 416 - 435
  • [26] Clinical advantages of computer-guided implant placement: a systematic review
    Hultin, Margareta
    Svensson, Krister G.
    Trulsson, Mats
    CLINICAL ORAL IMPLANTS RESEARCH, 2012, 23 : 124 - 135
  • [27] Advancing accuracy in guided implant placement: A comprehensive meta-analysis Meta-Analysis evaluation of the accuracy of available implant placement Methods
    Takacs, Anna
    Hardi, Eszter
    Cavalcante, Bianca Golzio Navarro
    Szabo, Bence
    Kispelyi, Barbara
    Joob-Fancsaly, Arpad
    Mikulas, Krisztina
    Varga, Gabor
    Hegyi, Peter
    Kivovics, Marton
    JOURNAL OF DENTISTRY, 2023, 139
  • [28] The Accuracy of Zygomatic Implant Placement Assisted by Dynamic Computer-Aided Surgery: A Systematic Review and Meta-Analysis
    Fan, Shengchi
    Saenz-Ravello, Gustavo
    Diaz, Leonardo
    Wu, Yiqun
    Davo, Ruben
    Wang, Feng
    Magic, Marko
    Al-Nawas, Bilal
    Kaemmerer, Peer W.
    JOURNAL OF CLINICAL MEDICINE, 2023, 12 (16)
  • [29] Prophylactic antibiotic regimens in dental implant failure A systematic review and meta-analysis
    Braun, Rosalie S.
    Chambrone, Leandro
    Khouly, Ismael
    JOURNAL OF THE AMERICAN DENTAL ASSOCIATION, 2019, 150 (06) : E61 - E91
  • [30] A systematic review on the accuracy and the clinical outcome of computer-guided template-based implant dentistry
    Schneider, David
    Marquardt, Pascal
    Zwahlen, Marcel
    Jung, Ronald E.
    CLINICAL ORAL IMPLANTS RESEARCH, 2009, 20 : 73 - 86