CLINICAL FACTORS AFFECTING THE ACCURACY OF GUIDED IMPLANT SURGERY-A SYSTEMATIC REVIEW AND META-ANALYSIS

被引:148
|
作者
Zhou, Wenjuan [1 ,2 ,3 ]
Liu, Zhonghao [1 ]
Song, Liansheng [2 ]
Kuo, Chia-Ling [4 ]
Shafer, David M. [2 ]
机构
[1] Binzhou Med Univ, Yantai Stomatol Hosp, Dept Implant Dent, Yantai, Peoples R China
[2] UConn Sch Dent Med, Div Oral & Maxillofacial Surg, 263 Farmington Ave, Farmington, CT 06030 USA
[3] Med Univ Vienna, Univ Clin Dent, Competent Ctr Periodontal Res, Div Conservat Dent & Periodontol, Vienna, Austria
[4] UConn Hlth, CT Inst Clin & Translat Sci, Farmington, CT USA
关键词
Dental implants; Computer-assisted; Guided surgery; Surgical guides; Accuracy; CONE-BEAM CT; STEREOLITHOGRAPHIC SURGICAL TEMPLATES; COMPUTED-TOMOGRAPHY; DENTAL IMPLANTS; PLACEMENT; COMPLICATIONS; RELIABILITY; NAVIGATION; POSITIONS; DEVIATION;
D O I
10.1016/j.jebdp.2017.07.007
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Objectives To systematically review the current dental literature regarding clinical accuracy of guided implant surgery and to analyze the involved clinical factors. Material and Methods PubMed and Cochrane Central Register of Controlled Trials were searched. Meta-analysis and meta-regression analysis were performed. Clinical studies with the following outcome measurements were included: (1) angle deviation, (2) deviation at the entry point, and (3) deviation at the apex. The involved clinical factors were further evaluated. Results Fourteen clinical studies from 1951 articles initially identified met the inclusion criteria. Meta-regression analysis revealed a mean deviation at the entry point of 1.25 mm (95% confidence interval [CI]: 1.22-1.29), 1.57 mm (95% CI: 1.53-1.62) at the apex, and 4.1 degrees in angle (95% CI: 3.97-4.23). A statistically significant difference (P<.001) was observed in angular deviations between the maxilla and mandible. Partially guided surgery showed a statistically significant greater deviation in angle (P<. 001), at the entry point (P<. 001), and at the apex (P<. 001) compared with totally guided surgery. The outcome of guided surgery with flapless approach indicated significantly more accuracy in angle (P<. 001), at the entry point (P<.001), and at apex (P<.001). Significant differences were observed in angular deviation based on the use of fixation screw (P<. 001). Conclusions The position of guide, guide fixation, type of guide, and flap approach could influence the accuracy of computer-aided implant surgery. A totally guided system using fixation screws with a flapless protocol demonstrated the greatest accuracy. Future clinical research should use a standardized measurement technique for improved accuracy.
引用
收藏
页码:28 / 40
页数:13
相关论文
共 50 条
  • [1] Accuracy of Augmented Reality-Assisted Navigation in Dental Implant Surgery: Systematic Review and Meta-analysis
    Mai, Hang-Nga
    Dam, Van Viet
    Lee, Du-Hyeong
    JOURNAL OF MEDICAL INTERNET RESEARCH, 2023, 25 (01)
  • [2] Influence of clinical and technical parameters on accuracy of guided implant placement. Systematic review and meta-analysis
    Kasradze, D.
    Segalyte, E.
    Kubilius, R.
    JOURNAL OF OSSEOINTEGRATION, 2021, 13 (04) : 198 - 219
  • [3] The accuracy of implant placement with computer-guided surgery in partially edentulous patients and possible influencing factors: A systematic review and meta-analysis
    Putra, Ramadhan Hardani
    Yoda, Nobuhiro
    Astuti, Eha Renwi
    Sasaki, Keiichi
    JOURNAL OF PROSTHODONTIC RESEARCH, 2022, 66 (01) : 29 - 39
  • [4] Accuracy of dynamic navigation in implant surgery: A systematic review and meta-analysis
    Wei, Shi-Min
    Zhu, Yu
    Wei, Jian-Xu
    Zhang, Chu-Nan
    Shi, Jun-Yu
    Lai, Hong-Chang
    CLINICAL ORAL IMPLANTS RESEARCH, 2021, 32 (04) : 383 - 393
  • [5] Accuracy of Different Systems of Guided Implant Surgery and Methods for Quantification: A Systematic Review
    Bautista, Nataly Marquez
    Meniz-Garcia, Cristina
    Lopez-Carriches, Carmen
    Sanchez-Labrador, Luis
    Brinkmann, Jorge Cortes-Breton
    Martinez-Pereda, Cristina Madrigal
    APPLIED SCIENCES-BASEL, 2024, 14 (24):
  • [6] Guided and Navigation Implant Surgery: A Systematic Review
    Aghaloo, Tara
    Hadaya, Danny
    Schoenbaum, Todd R.
    Pratt, Lauren
    Favagehi, Mehrdad
    INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2023, 38 : 7 - 15b
  • [7] Accuracy of robotic surgery for dental implant placement: A systematic review and meta-analysis
    Wu, Xin-Yu
    Shi, Jun-Yu
    Qiao, Shi-Chong
    Tonetti, Maurizio S.
    Lai, Hong-Chang
    CLINICAL ORAL IMPLANTS RESEARCH, 2024, 35 (06) : 598 - 608
  • [8] Dynamic Navigation in Implant Dentistry: A Systematic Review and Meta-analysis
    Pellegrino, Gerardo
    Ferri, Agnese
    Del, Massimo
    Prati, Carlo
    Gandolfi, Maria Giovanna
    Marchetti, Claudio
    INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2021, 36 (05) : E121 - E140
  • [9] Accuracy of Dynamic Computer-Assisted Implant Placement: A Systematic Review and Meta-Analysis of Clinical and In Vitro Studies
    Schnutenhaus, Sigmar
    Edelmann, Cornelia
    Knipper, Anne
    Luthardt, Ralph G.
    JOURNAL OF CLINICAL MEDICINE, 2021, 10 (04) : 1 - 20
  • [10] Accuracy of implant placement with computer-aided static, dynamic, and robot-assisted surgery: a systematic review and meta-analysis of clinical trials
    Khaohoen, Angkoon
    Powcharoen, Warit
    Sornsuwan, Tanapon
    Chaijareenont, Pisaisit
    Rungsiyakull, Chaiy
    Rungsiyakull, Pimduen
    BMC ORAL HEALTH, 2024, 24 (01)