Control charts to evaluate long-term performance in proficiency tests

被引:8
|
作者
Sorbo, Angela [1 ]
Colabucci, Andrea [1 ]
Ciaralli, Laura [1 ]
机构
[1] Ist Super Sanita, Dept Food Safety & Vet Publ Hlth, European Union Reference Lab Chem Elements Food A, I-00161 Rome, Italy
关键词
European Union Reference Laboratory; Chemical elements; Proficiency test; Shewhart control charts; Cusum control charts; Long-term performance;
D O I
10.1007/s00769-013-0956-0
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
As proficiency tests (PTs) provider, the European Union Reference Laboratory for Chemical Elements in Food of Animal Origin (EURL-CEFAO) yearly organizes exercises on the determination of chemical elements within the area of its mandate. The scheme is addressed to the National Reference Laboratories (NRLs) of the European Union Member States. Each PT is planned giving priority to the matrices and elements for which maximum levels are set in Commission Regulation No. 1881/2006 and following amendments as well as to those mainly considered in National Residues Control Plans. Samples to be distributed are prepared in the Laboratory's facilities using materials purchased on the market and often adjusting the concentration levels of the analytes around their maximum levels. In the 2006-2011 period, PTs were planned as a long-term programme pursuing the general objective of providing the NRLs with a scheme that can give them the opportunity to check and improve the performance of their analytical methods and to verify the effectiveness of any corrective actions through the repetition of the same matrix. Control charts give participants the possibility of a long-term follow-up of their performance promoting the improvement of Quality Control. To this aim, Shewhart and Cusum control charts for z-scores are prepared according to ISO 13528:2005 and updated after each PT for each laboratory. z-scores are assigned using values of sigma (pEURL-CEFAO) that correspond to the level of performance appropriate to the demand. Cusum charts are also evaluated by EURL-CEFAO in order to identify problems that may cause a bias in the measurement method.
引用
收藏
页码:291 / 298
页数:8
相关论文
共 50 条
  • [1] Control charts to evaluate long-term performance in proficiency tests
    Angela Sorbo
    Andrea Colabucci
    Laura Ciaralli
    Accreditation and Quality Assurance, 2013, 18 : 291 - 298
  • [2] Proficiency tests on olive oil organized by the Italian National Reference Laboratory for pesticides: long-term performance of laboratories
    Generali, Tiziana
    Stefanelli, Patrizia
    Girolimetti, Silvana
    Barbini, Danilo Attard
    ACCREDITATION AND QUALITY ASSURANCE, 2015, 20 (04) : 247 - 253
  • [3] Proficiency tests on olive oil organized by the Italian National Reference Laboratory for pesticides: long-term performance of laboratories
    Tiziana Generali
    Patrizia Stefanelli
    Silvana Girolimetti
    Danilo Attard Barbini
    Accreditation and Quality Assurance, 2015, 20 : 247 - 253
  • [4] Forensic laboratory tests to evaluate long-term performance of reclaimed asphalt pavements: Connecticut case study
    Yut, Iliya
    Mahoney, James
    McDonnel, Anne-Marie
    ROAD MATERIALS AND PAVEMENT DESIGN, 2017, 18 : 311 - 335
  • [5] Long-term Performance of Greek IPOs
    Thomadakis, Stavros
    Nounis, Christos
    Gounopoulos, Dimitrios
    EUROPEAN FINANCIAL MANAGEMENT, 2012, 18 (01) : 117 - 141
  • [6] Model Tests on the Long-Term Dynamic Performance of Offshore Wind Turbines Founded on Monopiles in Sand
    Guo, Zhen
    Yu, Luqing
    Wang, Lizhong
    Bhattacharya, S.
    Nikitas, G.
    Xing, Yuelong
    JOURNAL OF OFFSHORE MECHANICS AND ARCTIC ENGINEERING-TRANSACTIONS OF THE ASME, 2015, 137 (04):
  • [7] Assessment of the long-term hydrological performance of a green roof system in stormwater control
    Dong, Zhaokai
    Bain, Daniel J.
    Buck, John K.
    Ng, Carla
    JOURNAL OF ENVIRONMENTAL MANAGEMENT, 2024, 370
  • [8] The performance of bootstrap control charts
    Jones, LA
    Woodall, WH
    JOURNAL OF QUALITY TECHNOLOGY, 1998, 30 (04) : 362 - 375
  • [9] Long-term performance of Passive House buildings
    Wolfgang Hasper
    Thomas Kirtschig
    Mark Siddall
    David Johnston
    Gernot Vallentin
    Jack Harvie-Clark
    Energy Efficiency, 2021, 14
  • [10] Long-term performance of heat exchanger piles
    C. Guney Olgun
    Tolga Y. Ozudogru
    Sherif L. Abdelaziz
    Aykut Senol
    Acta Geotechnica, 2015, 10 : 553 - 569