Dual-Modality Imaging of Cancer with SPECT/CT

被引:74
|
作者
Hasegawa, Bruce H. [1 ,2 ,3 ,4 ]
Wong, Kenneth H. [1 ,2 ,3 ,4 ]
Iwata, Koji [1 ,4 ]
Barber, William C. [1 ,4 ]
Hwang, Andrew B. [1 ,2 ,3 ]
Sakdinawat, Anne E. [1 ,4 ]
Ramaswamy, Mohan [4 ]
Price, David C. [4 ]
Hawkins, Randall A. [2 ,3 ,4 ]
机构
[1] Univ Calif San Francisco, Phys Res Lab, San Francisco, CA 94080 USA
[2] Univ Calif San Francisco, Bioengn Grad Grp, San Francisco, CA 94143 USA
[3] Univ Calif Berkeley, San Francisco, CA 94143 USA
[4] Univ Calif San Francisco, Dept Radiol, San Francisco, CA 94143 USA
关键词
radionuclide imaging; computed tomography; tumor imaging;
D O I
10.1177/153303460200100605
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Dual-modality imaging is an in vivo diagnostic technique that obtains structural and functional information directly from patient studies in a way that cannot be achieved with separate imaging systems alone. Dual-modality imaging systems are configured by combining computed tomography (CT) with radionuclide imaging (using positron emission tomography (PET) or single-photon emission computed tomography (SPECT)) on a single gantry which allows both functional and structural imaging to be performed during a single imaging session without having the patient leave the imaging system. A SPECT/CT system developed at UCSF is being used in a study to determine if dual-modality imaging offers advantages for assessment of patients with prostate cancer using In-111-ProstaScint (R), a radiolabeled antibody for the prostate-specific membrane antigen. In-111-ProstaScint (R) images are reconstructed using an iterative maximum-likelihood expectation-maximization (ML-EM) algorithm with correction for photon attenuation using a patient-specific map of attenuation coefficients derived from CT. The ML-EM algorithm accounts for the dual-photon nature of the In-111-labeled radionuclide, and incorporates correction for the geometric response of the radionuclide collimator. The radionuclide image then can be coregistered and overlaid in color on a grayscale CT image for improved localization of the functional information from SPECT. Radionuclide images obtained with SPECT/CT and reconstructed using ML-EM with correction for photon attenuation and collimator response improve image quality in comparison to conventional radionuclide images obtained with filtered backprojection reconstruction. These results illustrate the potential advantages of dual-modality imaging for improving the quality and the localization of radionuclide uptake for staging disease, planning treatment, and monitoring therapeutic response in patients with cancer.
引用
收藏
页码:449 / 458
页数:10
相关论文
共 50 条
  • [21] A Novel Metal-Based Imaging Probe for Targeted Dual-Modality SPECT/MR Imaging of Angiogenesis
    Tsoukalas, Charalampos
    Psimadas, Dimitrios
    Kastis, George A.
    Koutoulidis, Vassilis
    Harris, Adrian L.
    Paravatou-Petsotas, Maria
    Karageorgou, Maria
    Furenlid, Lars R.
    Moulopoulos, Lia A.
    Stamopoulos, Dimosthenis
    Bouziotis, Penelope
    FRONTIERS IN CHEMISTRY, 2018, 6
  • [22] Effect of contrast agent bolus passage on dual-modality PET/CT imaging
    Antoch, G
    Freudenberg, LS
    Egelhof, T
    Stattaus, J
    Bockisch, A
    Debatin, JF
    RADIOLOGY, 2002, 225 : 383 - 383
  • [23] Detection of Breast Cancer Microcalcifications Using a Dual-modality SPECT/NIR Fluorescent Probe
    Bhushan, Kumar R.
    Misra, Preeti
    Liu, Fangbing
    Mathur, Sanjeev
    Lenkinski, Robert E.
    Frangioni, John V.
    JOURNAL OF THE AMERICAN CHEMICAL SOCIETY, 2008, 130 (52) : 17648 - +
  • [24] Dual-modality gene reporter for in vivo imaging
    Patrick, P. Stephen
    Hammersley, Jayne
    Loizou, Louiza
    Kettunen, Mikko I.
    Rodrigues, Tiago B.
    Hu, De-En
    Tee, Sui-Seng
    Hesketh, Robin
    Lyons, Scott K.
    Soloviev, Dmitry
    Lewis, David Y.
    Aime, Silvio
    Fulton, Sandra M.
    Brindle, Kevin M.
    PROCEEDINGS OF THE NATIONAL ACADEMY OF SCIENCES OF THE UNITED STATES OF AMERICA, 2014, 111 (01) : 415 - 420
  • [25] SPECT/fluorescence dual-modality imaging of carcinoembryonic antigen-expressing tumors: a pretargeting study
    Rijpkema, M.
    Sharkey, R.
    Bos, D.
    McBride, W.
    Oyen, W.
    Goldenberg, D.
    Boerman, O.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2013, 40 : S154 - S155
  • [26] Mapping of bioluminescent images onto CT volume surface for dual-modality BLT and CT imaging
    Chen, Xueli
    Liang, Jimin
    Qu, Xiaochao
    Hou, Yanbin
    Zhu, Shouping
    Chen, Duofang
    Gao, Xinbo
    Tian, Jie
    JOURNAL OF X-RAY SCIENCE AND TECHNOLOGY, 2012, 20 (01) : 31 - 44
  • [27] Development and Assessment of Statistical Iterative Image Reconstruction for CT on a Small Animal SPECT/CT Dual-Modality System
    Dai, Tiantian
    Deng, Xiao
    Ionita, Ciprian N.
    Wei, Qingyang
    Ma, Tianyu
    Liu, Yaqiang
    Bednarek, Daniel R.
    Rudin, Stephen
    Yao, Rutao
    2012 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE RECORD (NSS/MIC), 2012, : 3409 - 3411
  • [28] Dual-modality scanner for small animal imaging
    Stolin, Alexander
    Pole, Donald
    Wojcik, Randolph
    Williams, Mark B.
    2006 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOL 1-6, 2006, : 2403 - 2407
  • [29] Radiosensitivity of Fluorophores: Implications for Dual-Modality Imaging
    Hernandez, Reinier
    Heskamp, Sandra
    Rijpkema, Mark
    Goldenberg, David
    McBride, Bill
    Morgenstern, Alfred
    Bruchertseifer, Frank
    Cai, Weibo
    Boerman, Otto
    JOURNAL OF NUCLEAR MEDICINE, 2015, 56 (03)
  • [30] Dual-modality PET/ultrasound imaging of the prostate
    Huber, J. S.
    Moses, W. W.
    Pouliot, J.
    Hsu, I. C.
    2005 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-5, 2005, : 2187 - 2190