Balanced detection spectral domain optical coherence tomography with a multiline single camera for signal-to-noise ratio enhancement

被引:11
作者
Kuo, Wen-Chuan [1 ,2 ]
Lai, Yune-Shee [3 ]
Lai, Chih-Ming [4 ]
Huang, Yi-Shiang [1 ,3 ]
机构
[1] Natl Yang Ming Univ, Inst Biophoton, Taipei, Taiwan
[2] Natl Yang Ming Univ, Biophoton & Mol Imaging Res Ctr BMIRC, Taipei 112, Taiwan
[3] Natl Taiwan Normal Univ, Inst Electroopt Sci & Technol, Taipei 106, Taiwan
[4] Ming Chuan Univ, Dept Elect Engn, Tao Yuan 333, Taiwan
关键词
INTERFEROMETRY; LASER;
D O I
10.1364/AO.51.005936
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
In this study, the use and advantages of balanced detection (BD) in spectral domain optical coherence tomography (SD-OCT) are demonstrated. A-scans are calculated as a combination of two phase-opposed interferometric spectra acquired simultaneously by using a multiline single camera spectrometer. Not only does this system suppress artifacts due to autocorrelation, but also the signal of interest is increased by a factor of 2 as experimentally verified. Our BD-based SD-OCT gives a signal-to-noise ratio improvement of 8-14 dB for the peak within 1 mm compared to standard SD-OCT using a single detection scheme. This method is validated by experimental measurement of a glass plate. c 2012 Optical Society of America
引用
收藏
页码:5936 / 5940
页数:5
相关论文
共 19 条
[11]   Fourier domain mode locking at 1050 nm for ultra-high-speed optical coherence tomography of the human retina at 236,000 axial scans per second [J].
Huber, R. ;
Adler, D. C. ;
Srinivasan, V. J. ;
Fujimoto, J. G. .
OPTICS LETTERS, 2007, 32 (14) :2049-2051
[12]   Performance of fourier domain vs. time domain optical coherence tomography [J].
Leitgeb, R ;
Hitzenberger, CK ;
Fercher, AF .
OPTICS EXPRESS, 2003, 11 (08) :889-894
[13]   Phase-shifting algorithm to achieve high-speed long-depth-range probing by frequency-domain optical coherence tomography [J].
Leitgeb, RA ;
Hitzenberger, CK ;
Fercher, AF ;
Bajraszewski, T .
OPTICS LETTERS, 2003, 28 (22) :2201-2203
[14]  
Lizuka K., 2002, ELEMENTS PHOTONICS
[15]   IN-VIVO RETINAL IMAGING BY OPTICAL COHERENCE TOMOGRAPHY [J].
SWANSON, EA ;
IZATT, JA ;
HEE, MR ;
HUANG, D ;
LIN, CP ;
SCHUMAN, JS ;
PULIAFITO, CA ;
FUJIMOTO, JG .
OPTICS LETTERS, 1993, 18 (21) :1864-1866
[16]   Differential spectral interferometry: an imaging technique for biomedical applications [J].
Vakhtin, AB ;
Peterson, KA ;
Wood, WR ;
Kane, DJ .
OPTICS LETTERS, 2003, 28 (15) :1332-1334
[17]   Simultaneous B-M-mode scanning method for real-time full-range Fourier domain optical coherence tomography [J].
Yasuno, Y ;
Makita, S ;
Endo, T ;
Aoki, G ;
Itoh, M ;
Yatagai, T .
APPLIED OPTICS, 2006, 45 (08) :1861-1865
[18]   High-speed optical frequency-domain imaging [J].
Yun, SH ;
Tearney, GJ ;
de Boer, JF ;
Iftimia, N ;
Bouma, BE .
OPTICS EXPRESS, 2003, 11 (22) :2953-2963
[19]   Removal of a mirror image and enhancement of the signal-to-noise ratio in Fourier-domain optical coherence tomography using an electro-optic phase modulator [J].
Zhang, J ;
Nelson, JS ;
Chen, ZP .
OPTICS LETTERS, 2005, 30 (02) :147-149