Impact of prior distributions and central tendency measures on Bayesian intravoxel incoherent motion model fitting

被引:48
|
作者
Gustafsson, Oscar [1 ,2 ]
Montelius, Mikael [1 ]
Starck, Goran [1 ,2 ]
Ljungberg, Maria [1 ,2 ]
机构
[1] Univ Gothenburg, Sahlgrenska Acad, Inst Clin Sci, Dept Radiat Phys, Gothenburg, Sweden
[2] Sahlgrens Univ Hosp, Dept Med Phys & Biomed Engn, Gothenburg, Sweden
基金
瑞典研究理事会;
关键词
intravoxel incoherent motion; Bayesian estimation; prior distribution; central tendency measure; DIFFUSION-WEIGHTED MRI; PROBABILITY-THEORY; BREAST-CANCER; B VALUES; PARAMETERS; PERFUSION; PILOT; LIVER;
D O I
10.1002/mrm.26783
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
PurposeBayesian model fitting has been proposed as a robust alternative for intravoxel incoherent motion (IVIM) model-fitting parameter estimation. However, consensus regarding choice of prior distribution and posterior distribution central tendency measure is needed. The aim of this study was to compare the quality of IVIM parameter estimates produced by different prior distributions and central tendency measures, and to gain knowledge about the effect of these choices. MethodsThree prior distributions (uniform, reciprocal, and lognormal) and two measures of central tendency (mean and mode) found in the literature were studied using simulations and in vivo data from a tumor mouse model. ResultsSimulations showed that the uniform and lognormal priors were superior to the reciprocal prior, especially for the parameters D and f and clinically relevant SNR levels. The choice of central tendency measure had less effect on the results, but had some effects on estimation bias. Results based on simulations and in vivo data agreed well, indicating high validity of the simulations. ConclusionsChoice of prior distribution and central tendency measure affects the results of Bayesian IVIM parameter estimates. This must be considered when comparing results from different studies. The best overall quality of IVIM parameter estimates was obtained using the lognormal prior. Magn Reson Med 79:1674-1683, 2018. (c) 2017 International Society for Magnetic Resonance in Medicine.
引用
收藏
页码:1674 / 1683
页数:10
相关论文
共 50 条
  • [1] A comparative simulation study of bayesian fitting approaches to intravoxel incoherent motion modeling in diffusion-weighted MRI
    While, Peter T.
    MAGNETIC RESONANCE IN MEDICINE, 2017, 78 (06) : 2373 - 2387
  • [2] Bayesian intravoxel incoherent motion parameter mapping in the human heart
    Spinner, Georg R.
    von Deuster, Constantin
    Tezcan, Kerem C.
    Stoeck, Christian T.
    Kozerke, Sebastian
    JOURNAL OF CARDIOVASCULAR MAGNETIC RESONANCE, 2017, 19
  • [3] Accurate intravoxel incoherent motion parameter estimation using Bayesian fitting and reduced number of low b-values
    Ye, Chen
    Xu, Daoyun
    Qin, Yongbin
    Wang, Lihui
    Wang, Rongpin
    Li, Wuchao
    Kuai, Zixiang
    Zhu, Yuemin
    MEDICAL PHYSICS, 2020, 47 (09) : 4372 - 4385
  • [4] Intravoxel Incoherent Motion MRI in the Brain: Impact of the Fitting Model on Perfusion Fraction and Lesion Differentiability
    Keil, Vera C.
    Maedler, Burkhard
    Gielen, Gerrit H.
    Pintea, Bogdan
    Hiththetiya, Kanishka
    Gaspranova, Alisa R.
    Gieseke, Juergen
    Simon, Matthias
    Schild, Hans H.
    Hadizadeh, Dariusch R.
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2017, 46 (04) : 1187 - 1199
  • [5] Improved Intravoxel Incoherent Motion Analysis of Diffusion Weighted Imaging by Data Driven Bayesian Modeling
    Orton, Matthew R.
    Collins, David J.
    Koh, Dow-Mu
    Leach, Martin O.
    MAGNETIC RESONANCE IN MEDICINE, 2014, 71 (01) : 411 - 420
  • [6] Histological Grading of Hepatocellular Carcinomas with Intravoxel Incoherent Motion Diffusion- weighted Imaging: Inconsistent Results Depending on the Fitting Method
    Ichikawa, Shintaro
    Motosugi, Utaroh
    Hernando, Diego
    Morisaka, Hiroyuki
    Enomoto, Nobuyuki
    Matsuda, Masanori
    Onishi, Hiroshi
    MAGNETIC RESONANCE IN MEDICAL SCIENCES, 2018, 17 (02) : 168 - 173
  • [7] Bayesian intravoxel incoherent motion parameter mapping in the human heart
    Georg R. Spinner
    Constantin von Deuster
    Kerem C. Tezcan
    Christian T. Stoeck
    Sebastian Kozerke
    Journal of Cardiovascular Magnetic Resonance, 19
  • [8] Initial study of biexponential model of intravoxel incoherent motion magnetic resonance imaging in evaluation of the liver fibrosis
    Chen Cuiyun
    Wang Bin
    Shi Dapeng
    Fu Fangfang
    Zhang Jiliang
    Wen Zejun
    Zhu Shaocheng
    Xu Junling
    Lin Qing
    Li Jing
    Dou Shewei
    CHINESE MEDICAL JOURNAL, 2014, 127 (17) : 3082 - 3087
  • [9] Accuracy of breast cancer lesion classification using intravoxel incoherent motion diffusion-weighted imaging is improved by the inclusion of global or local prior knowledge with bayesian methods
    Vidic, Igor
    Jerome, Neil P.
    Bathen, Tone F.
    Gao, Pal E.
    While, Peter T.
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2019, 50 (05) : 1478 - 1488
  • [10] Intravoxel incoherent motion MRI evaluation for the staging of liver fibrosis in a rat model
    Hu, Genwen
    Chan, Queenie
    Quan, Xianyue
    Zhang, Xuhui
    Li, Yufa
    Zhong, Xing
    Lin, Xiaoying
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2015, 42 (02) : 331 - 339