Kinematics of the Cervical Adjacent Segments After Disc Arthroplasty Compared With Anterior Discectomy and Fusion A Systematic Review and Meta-Analysis

被引:54
作者
Anderson, Paul A. [1 ]
Sasso, Rick C. [2 ]
Hipp, John [3 ]
Norvell, Daniel C. [4 ]
Raich, Annie [4 ]
Hashimoto, Robin [4 ]
机构
[1] Univ Wisconsin, Dept Orthoped & Rehabil, Madison, WI 53705 USA
[2] Indiana Univ Sch Med, Indiana Spine Grp, Indianapolis, IN USA
[3] Med Metr Inc, Houston, TX USA
[4] Spectrum Res Inc, Tacoma, WA USA
关键词
cervical fusion; adjacent segment degeneration; cervical arthroplasty; total disc replacement; spinal kinematics; LEVEL INTRADISCAL PRESSURE; INTERVERTEBRAL MOTION; REPLACEMENT; ARTHRODESIS; ALIGNMENT; QUALITY; SINGLE; RANGE; SPINE;
D O I
10.1097/BRS.0b013e31826d6628
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Study Design. Systematic review and meta-analysis. Objective. To determine the kinematics of the adjacent segments and global cervical spine after cervical arthroplasty compared with anterior cervical discectomy and fusion (ACDF). Summary of Background Data. Adjacent segment pathology after ACDF is a significant concern. Arthroplasty may decrease the risk of adjacent segment degeneration by maintaining normal spinal kinematics compared with fusion. However, the differences in the in vivo kinematics of the adjacent segments after cervical fusion versus arthroplasty have not been clearly established. Methods. A systematic literature review of studies comparing adjacent segment kinematic changes between fusion and arthroplasty was performed. We included randomized controlled trials and cohort studies that compared cervical arthroplasty with ACDF in adults with degenerative disease and reported on at least 1 outcome of interest. Meta-analysis was performed using a random-effects model where appropriate. The standardized mean difference of changes from baseline to follow-up between treatment groups was determined. Recommendations were made using Grades of Recommendation Assessment, Development, and Evaluation criteria. Results. We identified 12 studies, including 7 randomized controlled trials, 4 cohort studies, and 1 case-control study that evaluated kinematic measurements at the adjacent segments or the global cervical spine (C2-C7) after cervical arthroplasty compared with ACDF. We found no statistically significant differences between treatment groups in the change in range of motion (ROM) at the cranial or caudal adjacent segments from baseline to 2 years of follow-up. However, there was low evidence that the global cervical spine (C2-C7) had significantly greater change in ROM after arthroplasty compared with ACDF: patients had a greater angular ROM as measured up to 2 years after arthroplasty. We found no statistically significant differences between treatment groups in the change in the horizontal or vertical centers of rotation at the adjacent segments as measured up to 2 years after surgery. Regarding sagittal alignment, the cranial and caudal adjacent segments both became significantly more lordotic after arthroplasty compared with fusion at 1 to 2 years after surgery. However, there was no statistically significant difference between treatment groups in the change in global cervical sagittal alignment from baseline to 2 years. Conclusion. There is no statistically or clinically significant difference in the adjacent segment ROM or centers of rotation after cervical arthroplasty compared with ACDF. However, the change in sagittal alignment at the cranial and caudal adjacent segments was significantly more lordotic after arthroplasty compared with fusion. In addition, although we found that there was no statistically significant difference between treatment groups in the change in global cervical (C2-C7) sagittal alignment, there was a significantly greater change in the angular ROM of the cervical spine at up to 2 years after arthroplasty than occurred after fusion. Consensus Statement Patients can be advised that single-level arthroplasty and ACDF result in clinically similar kinematic changes at short-term follow-up. Strength of Statement: Strong
引用
收藏
页码:S85 / S95
页数:11
相关论文
共 26 条
[1]   Change in cervical range of motion and sagittal alignment in early and late phases after total disc replacement: radiographic follow-up exceeding 2 years Clinical article [J].
Ahn, Poong-Gi ;
Kim, Keung Nyun ;
Moon, Sung Whan ;
Kim, Keun Su .
JOURNAL OF NEUROSURGERY-SPINE, 2009, 11 (06) :688-695
[2]   Sagittal Cervical Alignment After Cervical Disc Arthroplasty and Anterior Cervical Discectomy and Fusion Results of a Prospective, Randomized, Controlled Trial [J].
Anakwenze, Okechukwu A. ;
Auerbach, Joshua D. ;
Milby, Andrew H. ;
Lonner, Baron S. ;
Balderston, Richard A. .
SPINE, 2009, 34 (19) :2001-2007
[3]  
Atkins D, 2004, BMJ-BRIT MED J, V328, P1490
[4]   Segmental Contribution Toward Total Cervical Range of Motion A Comparison of Cervical Disc Arthroplasty and Fusion [J].
Auerbach, Joshua D. ;
Anakwenze, Okechukwu A. ;
Milby, Andrew H. ;
Lonner, Baron S. ;
Balderston, Richard A. .
SPINE, 2011, 36 (25) :E1593-E1599
[5]   Changes in adjacent-level disc pressure and facet joint force after cervical arthroplasty compared with cervical discectomy and fusion [J].
Chang, Ung-Kyu ;
Kim, Daniel H. ;
Lee, Max C. ;
Willenberg, Rafer ;
Kim, Se-Hoon ;
Lim, Jesse .
JOURNAL OF NEUROSURGERY-SPINE, 2007, 7 (01) :33-39
[6]   Biomechanical comparison of single- and two-level cervical arthroplasty versus arthrodesis: effect on adjacent-level spinal kinematics [J].
Cunningham, Bryan W. ;
Hu, Nianbin ;
Zorn, Candace M. ;
McAfee, Paul C. .
SPINE JOURNAL, 2010, 10 (04) :341-349
[7]   Dynamic characteristics of the intact, fused, and prosthetic-replaced cervical disk [J].
Dahl, Michael C. ;
Rouleau, Jeffrey P. ;
Papadopoulos, Stephen ;
Nuckley, David J. ;
Ching, Randal P. .
JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME, 2006, 128 (06) :809-814
[8]   Adjacent level intradiscal pressure and segmental kinematics following a cervical total disc arthroplasty -: An In Vitro human cadaveric model [J].
Dmitriev, AE ;
Cunningham, BW ;
Hu, NB ;
Sell, G ;
Vigna, F ;
McAfee, PC .
SPINE, 2005, 30 (10) :1165-1172
[9]   Biomechanical study on the effect of cervical spine fusion on adjacent-level intradiscal pressure and segmental motion [J].
Eck, JC ;
Humphreys, SC ;
Lim, TH ;
Jeong, ST ;
Kim, JG ;
Hodges, SD ;
An, HS .
SPINE, 2002, 27 (22) :2431-2434
[10]   A kinematic study of the cervical spine before and after segmental arthrodesis [J].
Fuller, DA ;
Kirkpatrick, JS ;
Emery, SE ;
Wilber, RG ;
Davy, DT .
SPINE, 1998, 23 (15) :1649-1656