Do Newer-Generation Bioabsorbable Screws Become Incorporated into Bone at Two Years After ACL Reconstruction with Patellar Tendon Graft? A Cohort Study

被引:23
作者
Cox, Charles L. [1 ]
Spindler, Kurt P. [1 ]
Leonard, James P. [1 ]
Morris, Brent J. [1 ]
Dunn, Warren R. [1 ]
Reinke, Emily K. [1 ]
机构
[1] Vanderbilt Univ, Med Ctr, Vanderbilt Sports Med, Nashville, TN 37232 USA
关键词
CRUCIATE LIGAMENT RECONSTRUCTION; L-LACTIC ACID; PRETIBIAL CYST FORMATION; LONG-TERM ABSORPTION; POLY-L-LACTIDE; INTERFERENCE SCREWS; ENDOSCOPIC RECONSTRUCTION; SURGERY; DEGRADATION; RESORPTION;
D O I
10.2106/JBJS.L.01652
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background: Bioabsorbable interference screws are used frequently for graft fixation in ACL (anterior cruciate ligament) reconstruction. The resorption properties of many available screws that are marketed as bioabsorbable are not well defined. The CALAXO (Smith & Nephew Endoscopy) and MILAGRO (DePuy Synthes) bioabsorbable screws contain polymers of poly(lactic-co-glycolic acid) (PLGA) plus additives to encourage osseointegration overtime. The purpose of this study was to evaluate radiographic and magnetic resonance imaging (MRI) properties and compare patient-reported outcomes at a minimum of two years of follow-up after ACL reconstruction using CALAXO or MILAGRO bioabsorbable interference screws. Methods: A cohort of patients who underwent ACL reconstruction in which the fixation used was either CALAXO or MILAGRO screws returned for repeat radiographs for evaluation of tunnel widening, repeat MRI for evaluation of graft integrity and screw breakdown, and completion of the pain and symptom items of the KOOS (Knee injury and Osteoarthritis Outcome Score) questionnaire. Results: At a mean of three years (range, 2.5 to 4.0 years) after surgery, thirty-one patients with sixty-two CALAXO screws and thirty-six patients with seventy-two MILAGRO screws returned for repeat evaluation. Two blinded, independent reviewers found no significant differences between the two screw types when comparing radiographs for tibial or femoral tunnel widening or MRIs for graft integrity, tibial and femoral foreign body reactions, or femoral screw degradation. Both reviewers found a significant difference between the two screw types when comparing tibial screw degradation properties (p < 0.01). All analyzed CALAXO screws were rated as partially intact or degraded; the MILAGRO screws were more likely to be rated as intact. No significant differences were noted between the two screw types when comparing the two KOOS subscales. Conclusions: CALAXO screws in the tibial tunnel were more likely to be rated as degraded or partially degraded compared with MILAGRO screws at a mean of three years after implantation for ACL reconstruction. Although these newer-generation bioabsorbable screws were designed to promote osseointegration, no tunnel narrowing was noted, and in the majority of cases the remains of the screws were present at approximately three years.
引用
收藏
页码:244 / 250
页数:7
相关论文
共 26 条
[1]   Long-term absorption of β-tricalcium phosphate poly-L-lactic acid interference screws [J].
Barber, F. Alan ;
Dockery, William D. .
ARTHROSCOPY-THE JOURNAL OF ARTHROSCOPIC AND RELATED SURGERY, 2008, 24 (04) :441-447
[2]   Long-term absorption of poly-L-lactic acid interference screws [J].
Barber, F. Alan ;
Dockery, W. Dee .
ARTHROSCOPY-THE JOURNAL OF ARTHROSCOPIC AND RELATED SURGERY, 2006, 22 (08) :820-826
[3]   Long-Term Degradation of a Poly-Lactide Co-Glycolide/β-Tricalcium Phosphate Biocomposite Interference Screw [J].
Barber, F. Alan ;
Dockery, W. D. ;
Hrnack, Scott A. .
ARTHROSCOPY-THE JOURNAL OF ARTHROSCOPIC AND RELATED SURGERY, 2011, 27 (05) :637-643
[4]   Tissue restoration after resorption of polyglycolide and poly-laevo-lactic acid screws [J].
Böstman, OM ;
Laitinen, OM ;
Tynninen, O ;
Salminen, ST ;
Pihlajamäki, HK .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 2005, 87B (11) :1575-1580
[5]  
Busfield BT, 2007, ARTHROSCOPY, V23, pe14
[6]   Magnetic resonance imaging analysis of bioabsorbable interference screws used for fixation of bone-patellar tendon-bone autografts in endoscopic reconstruction of the anterior cruciate ligament [J].
Drogset, JO ;
Grontvedt, T ;
Myhr, G .
AMERICAN JOURNAL OF SPORTS MEDICINE, 2006, 34 (07) :1164-1169
[7]   Endoscopic reconstruction of the anterior cruciate ligament using bone-patellar tendon-bone grafts fixed with bioabsorbable or metal interference screws - A prospective randomized study of the clinical outcome [J].
Drogset, JO ;
Grontvedt, T ;
Tegnander, A .
AMERICAN JOURNAL OF SPORTS MEDICINE, 2005, 33 (08) :1160-1165
[8]   Tibial cyst and intra-articular granuloma formation after anterior cruciate ligament reconstruction using polylactide carbonate osteoconductive interference screws [J].
Dujardin, Jan ;
Vandenneucker, Hilde ;
Belleman, Johan .
ARTHROSCOPY-THE JOURNAL OF ARTHROSCOPIC AND RELATED SURGERY, 2008, 24 (02) :238-242
[9]   Is the Etiology of Pretibial Cyst Formation After Absorbable Interference Screw Use Related to a Foreign Body Reaction? [J].
Gonzalez-Lomas, Guillem ;
Cassilly, Ryan T. ;
Remotti, Fabrizio ;
Levine, William N. .
CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2011, 469 (04) :1082-1088
[10]   Resorption and Remodeling of Hydroxyapatite-Poly-L-Lactic Acid Composite Anterior Cruciate Ligament Interference Screws [J].
Johnston, Matt ;
Morse, Adam ;
Arrington, John ;
Pliner, Michele ;
Gasser, Seth .
ARTHROSCOPY-THE JOURNAL OF ARTHROSCOPIC AND RELATED SURGERY, 2011, 27 (12) :1671-1678