Comparison of the Glidescope®, the Pentax AWS®, and the Truview EVO2® with the Macintosh laryngoscope in experienced anaesthetists: a manikin study

被引:97
作者
Malik, M. A. [3 ]
O'Donoghue, C. [3 ]
Carney, J. [3 ]
Maharaj, C. H. [3 ]
Harte, B. H. [2 ,3 ]
Laffey, J. G. [1 ,2 ,3 ]
机构
[1] Natl Univ Ireland, Inst Clin Sci, Dept Anaesthesia, Clin Res Facil, Galway, Ireland
[2] Sligo Gen Hosp, Dept Anaesthesia, Sligo, Ireland
[3] Galway Univ Hosp, Dept Anaesthesia, Galway, Ireland
关键词
equipment; Pentax AWS (R) laryngoscope; Glidescope; (R); laryngoscope; Truview EVO2 (R) laryngoscope; Macintosh laryngoscope; manikin; intubation; tracheal; difficult intubation; UPPER CERVICAL-SPINE; TRACHEAL INTUBATION; AIRWAY-SCOPE; ENDOTRACHEAL INTUBATION; VIDEO LARYNGOSCOPE; DIFFICULT AIRWAY; MOVEMENT; AIRTRAQ; BLADE;
D O I
10.1093/bja/aen342
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
Background. The Pentax Airwayscope (R), the Glidescope (R), and the Truview EVO2 (R) constitute three novel laryngoscopes that facilitate visualization of the vocal cords without alignment of the oral, pharyngeal, and tracheal axes. We compared these devices with the Macintosh laryngoscope in a simulated easy and difficult laryngoscopy. Methods. Thirty-five experienced anaesthetists were allowed up to three attempts to intubate in each of four laryngoscopy scenarios in a Laerdal (R) SimMan (R) manikin. The time required to perform tracheal intubation, the success rate, number of intubation attempts and of optimization manoeuvres, and the severity of dental compression were recorded. Results. In the simulated easy laryngoscopy scenarios, there was no difference between the study devices and the Macintosh in success of tracheal intubation. In more difficult tracheal intubation scenarios, the Glidescope (R) and Pentax AWS (R), and to a lesser extent the Truview EVO2 (R) laryngoscope demonstrated advantages over the Macintosh laryngoscope including a better view of the glottis, greater success of tracheal intubation, and ease of device use. The Pentax AWS (R) was more successful in achieving tracheal intubation, required less time to successfully perform tracheal intubation, caused less dental trauma, and was considered by the anaesthetists to be easier to use. Conclusions. The Pentax AWS (R) laryngoscope demonstrated more advantages over the Macintosh laryngoscope than either the Truview EVO2 (R) or the Glidescope (R) laryngoscope, when used by experienced anaesthetists in difficult tracheal intubation scenarios.
引用
收藏
页码:128 / 134
页数:7
相关论文
共 19 条
[1]   A comparison of the Truview® blade with the Macintosh blade in adult patients [J].
Barak, M. ;
Philipchuck, P. ;
Abecassis, P. ;
Katz, Y. .
ANAESTHESIA, 2007, 62 (08) :827-831
[2]   RAPIDITY AND ACCURACY OF TRACHEAL INTUBATION IN A MANNEQUIN - COMPARISON OF THE FIBEROPTIC WITH THE BULLARD LARYNGOSCOPE [J].
DYSON, A ;
HARRIS, J ;
BHATIA, K .
BRITISH JOURNAL OF ANAESTHESIA, 1990, 65 (02) :268-270
[3]   Pentax-AWS, a new videolaryngoscope, is more effective than the Macintosh laryngoscope for tracheal intubation in patients with restricted neck movements: a randomized comparative study [J].
Enomoto, Y. ;
Asai, T. ;
Arai, T. ;
Kamishima, K. ;
Okuda, Y. .
BRITISH JOURNAL OF ANAESTHESIA, 2008, 100 (04) :544-548
[4]   Tracheal intubation by non-anaesthetist physicians using the Airway Scope [J].
Hirabayashi, Yoshihiro ;
Seo, Norimasa .
EMERGENCY MEDICINE JOURNAL, 2007, 24 (08) :572-573
[5]   An evaluation of the TruView EVO2 laryngoscope [J].
Li, J. B. ;
Xiong, Y. C. ;
Wang, X. L. ;
Fan, X. H. ;
Li, Y. ;
Xu, H. ;
Ma, Y. ;
Deng, X. M. .
ANAESTHESIA, 2007, 62 (09) :940-943
[6]   Comparison of the GlideScope® with the Macintosh laryngoscope for tracheal intubation in patients with simulated difficult airway [J].
Lim, Y ;
Yeo, SW .
ANAESTHESIA AND INTENSIVE CARE, 2005, 33 (02) :243-247
[7]   A comparison of direct and indirect laryngoscopes and the ILMA in novice users: a manikin study [J].
Maharaj, C. H. ;
McDonnell, J. G. ;
Harte, B. H. ;
Laffey, J. G. .
ANAESTHESIA, 2007, 62 (11) :1161-1166
[8]   Evaluation of intubation using the Airtraq® or Macintosh laryngoscope by anaesthetists in easy and simulated difficult laryngoscopy -: a manikin study [J].
Maharaj, CH ;
Higgins, BD ;
Harte, BH ;
Laffey, JG .
ANAESTHESIA, 2006, 61 (05) :469-477
[9]   Endotracheal intubation in patients with cervical spine immobilization - A comparison of Macintosh and Airtraq laryngoscopes [J].
Maharaj, Chrisen H. ;
Buckley, Elma ;
Harte, Brian H. ;
Laffey, John G. .
ANESTHESIOLOGY, 2007, 107 (01) :53-59
[10]   Tracheal intubation by inexperienced medical residents using the Airtraq and Macintosh laryngoscopes - a manikin study [J].
Maharaj, Chrisen H. ;
Chonghaile, Martina Ni ;
Higgins, Brendan D. ;
Harte, Brian H. ;
Laffey, John G. .
AMERICAN JOURNAL OF EMERGENCY MEDICINE, 2006, 24 (07) :769-774