Biometry of cataractous eyes using partial coherence interferometry - Clinical feasibility study of a commercial prototype I

被引:54
作者
Kiss, B
Findl, O
Menapace, R
Wirtitsch, M
Drexler, W
Hitzenberger, CK
Fercher, AF
机构
[1] Univ Vienna, Inst Med Phys, A-1090 Vienna, Austria
[2] Allgemeines Krankenhaus Wien, Univ Klin Augenheilkunde, Vienna, Austria
关键词
D O I
10.1016/S0886-3350(01)01272-X
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose. To evaluate the clinical feasibility of the prototype version of a commercial partial coherence interferometry instrument (axial length measurement, ALM, Carl Zeiss Jena) for noninvasive, high-precision biometry in cataractous eyes. Setting: Department of Ophthalmology, Vienna General Hospital, and Institute of Medical Physics, University of Vienna, Austria. Methods. The preoperative axial length in 49 eyes of 37 cataract patients was measured with the commercial (ALM) and laboratory (PCI) prototypes of the partial coherence interferometry instrument, as well as with immersion ultrasound (IUS). Results: Axial length measurements with the ALM and PCI did not differ significantly (P=.23). Both prototypes assessed longer axial lengths than the IUS technique (P<.0001; median 203 mu m; range -476 to +635 mu m). The precision of the axial length measurement was 18 mu m, 28 mu m, and 54 mu m with the PCI, ALM, and IUS, respectively. Conclusions: Partial coherence tomography is a high-precision, high-resolution, noncontact biometric technique. The commercial PCI prototype is practical in clinical use, with improved comfort for patients, no need for anesthesia, and a reduced risk of infection. However, the difference between the PCI and IUS in axial length measurement must be considered when using the constants supplied by intraocular lens (IOL) manufacturers for IOL power calculations, J Cataract Refract Surg 2002, 28.224-229 (C) 2002 ASCRS and ESCRS.
引用
收藏
页码:224 / 229
页数:6
相关论文
共 28 条
[1]  
American National Standards Institute, 1986, Z1361 ANSI
[2]   AXIAL LENGTH MEASUREMENTS WITH DIFFERENT ULTRASONIC DEVICES [J].
ARTARIA, LG .
KLINISCHE MONATSBLATTER FUR AUGENHEILKUNDE, 1986, 188 (05) :492-494
[3]  
Bamber JC., 1988, PHYS MED IMAGING, P319
[4]  
BINKHORST RD, 1981, OPHTHALMIC SURG LAS, V12, P363
[5]   INTRAOCULAR-LENS POWER CALCULATIONS - THE OPTIMAL APPROACH [J].
BOERRIGTER, RMM ;
THIJSSEN, JM ;
VERBEEK, AM .
OPHTHALMOLOGICA, 1985, 191 (02) :89-94
[6]   Investigation of dispersion effects in ocular media by multiple wavelength partial coherence interferometry [J].
Drexler, W ;
Hitzenberger, CK ;
Baumgartner, A ;
Findl, O ;
Sattmann, H ;
Fercher, AF .
EXPERIMENTAL EYE RESEARCH, 1998, 66 (01) :25-33
[7]  
Drexler W, 1997, INVEST OPHTH VIS SCI, V38, P1304
[8]   Partial coherence interferometry: A novel approach to biometry in cataract surgery [J].
Drexler, W ;
Findl, O ;
Menapace, R ;
Rainer, G ;
Vass, C ;
Hitzenberger, CK ;
Fercher, AF .
AMERICAN JOURNAL OF OPHTHALMOLOGY, 1998, 126 (04) :524-534
[9]  
Fercher A. F., 1986, Proceedings of the SPIE - The International Society for Optical Engineering, V658, P48, DOI 10.1117/12.938523
[10]  
Fercher A F, 1996, J Biomed Opt, V1, P157, DOI 10.1117/12.231361