CT evaluation of coronary artery stents with iterative image reconstruction: improvements in image quality and potential for radiation dose reduction

被引:84
作者
Ebersberger, Ullrich [2 ,3 ,4 ]
Tricarico, Francesco [2 ,3 ,5 ]
Schoepf, U. Joseph [1 ,2 ,3 ]
Blanke, Philipp [2 ,3 ,6 ]
Spears, J. Reid [2 ,3 ]
Rowe, Garrett W. [2 ,3 ]
Halligan, William T. [2 ,3 ]
Henzler, Thomas [2 ,3 ,7 ]
Bamberg, Fabian [8 ]
Leber, Alexander W. [9 ]
Hoffmann, Ellen [4 ]
Apfaltrer, Paul [2 ,3 ,7 ]
机构
[1] Med Univ S Carolina, Heart & Vasc Ctr, Charleston, SC 29425 USA
[2] Med Univ S Carolina, Dept Radiol & Radiol Sci, Charleston, SC 29425 USA
[3] Med Univ S Carolina, Div Cardiol, Dept Med, Charleston, SC 29425 USA
[4] Heart Ctr Munich Bogenhausen, Dept Cardiol & Intens Care Med, Munich, Germany
[5] Univ Cattolica Sacro Cuore, Dept Bioimaging & Radiol Sci, A Gemelli Hosp, I-00168 Rome, Italy
[6] Univ Hosp Freiburg, Dept Diagnost Radiol, Freiburg, Germany
[7] Heidelberg Univ, Inst Clin Radiol & Nucl Med, Univ Med Ctr Mannheim, Med Fac Mannheim, Heidelberg, Germany
[8] Univ Munich, Inst Clin Radiol, Munich, Germany
[9] Univ Toronto, Sunnybrook Hlth Sci Ctr, Schulich Heart Ctr, Inst Cardiovasc Intervent & Imaging, Toronto, ON, Canada
关键词
Iterative reconstruction; SAFIRE; Dual-source CT; Coronary artery stents; Coronary CT angiography; FILTERED BACK-PROJECTION; ANGIOGRAPHY;
D O I
10.1007/s00330-012-2580-5
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Comparison of coronary artery stent assessment with cardiac CT angiography (cCTA) using traditional filtered back projection (FBP) and sinogram affirmed iterative reconstruction (SAFIRE), in both full- and half-radiation dose image data. Dual-source cCTA studies of 37 implanted stents were reconstructed at full- and half-radiation dose with FBP and SAFIRE. Half-dose data were based on projections from one DSCT detector. In-stent noise, signal-to-noise ratio (SNR), and stent-lumen attenuation increase ratio (SAIR) were measured and image quality graded. Stent volumes were measured to gauge severity of beam hardening artefacts. Full-dose SAFIRE reconstructions were superior to full-dose FBP vis-A -vis in-stent noise (21.2 +/- 6.6 vs. 35.7 +/- 17.5; P < 0.05), SNR (22.1 +/- 8.6 vs. 14.3 +/- 6.7; P < 0.05), SAIR (19.6 +/- 17.6 vs. 33.4 +/- 20.4%; P < 0.05), and image quality (4.2 +/- 0.86 vs. 3.5 +/- 1.0; P < 0.05). Stent volumes were lower measured with SAFIRE (119.9 +/- 53.7 vs. 129.8 +/- 65.0 mm(3); P > 0.05). Comparing half-dose SAFIRE with full-dose FBP, in-stent noise (26.7 +/- 13.0 vs. 35.7 +/- 17.5; P < 0.05) and SNR (18.2 +/- 6.9 vs. 14.3 +/- 6.7; P < 0.05) improved significantly. SAIR (31.6 +/- 24.3 vs. 33.4 +/- 20.4%; P > 0.05), stent volume (129.6 +/- 57.3 vs. 129.8 +/- 65.0 mm(3); P > 0.05), and image quality (3.5 +/- 1.0 vs. 3.7 +/- 1.1; P > 0.05) did not differ. Radiation dose decreased from 8.7 +/- 5.2 to 4.3 +/- 2.6 mSv. Iterative reconstruction significantly improves imaging of coronary artery stents by CT compared with FBP, even with half-radiation-dose data. aEuro cent Computed tomography (CT) is becoming an increasingly important investigation for cardiac problems. aEuro cent Iterative CT reconstruction techniques significantly improve coronary artery stent evaluation. aEuro cent Iterative reconstruction has the potential to reduce radiation dose requirements. aEuro cent Improved stent visualisation detects complications better, further reducing the need for catheterisation.
引用
收藏
页码:125 / 132
页数:8
相关论文
共 26 条
[1]   Repeat percutaneous coronary revascularization: Indications and outcomes in a "Real World" cohort [J].
Adlam, David ;
Evans, Nicholas ;
Malhotra, Aneil ;
Midha, Disha ;
Rowley, Felicity ;
Hutchings, David ;
Shin, Mirae ;
Mole, Guy ;
Stockenhuber, Alexander ;
Lumb, Mark ;
Wordsworth, Jonathan ;
Frantal, Sophie ;
Forfar, J. Colin .
CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2012, 80 (04) :539-545
[2]   High diagnostic accuracy of prospective ECG-gating 64-slice computed tomography coronary angiography for the detection of in-stent restenosis [J].
Andreini, Daniele ;
Pontone, Gianluca ;
Bartorelli, Antonio L. ;
Mushtaq, Saima ;
Trabattoni, Daniela ;
Bertella, Erika ;
Cortinovis, Sarah ;
Annoni, Andrea ;
Formenti, Alberto ;
Ballerini, Giovanni ;
Agostoni, Piergiuseppe ;
Fiorentini, Cesare ;
Pepi, Mauro .
EUROPEAN RADIOLOGY, 2011, 21 (07) :1430-1438
[3]  
[Anonymous], 2004, EUROPEAN GUIDELINES
[4]   CT image quality improvement using adaptive iterative dose reduction with wide-volume acquisition on 320-detector CT [J].
Gervaise, Alban ;
Osemont, Benoit ;
Lecocq, Sophie ;
Noel, Alain ;
Micard, Emilien ;
Felblinger, Jacques ;
Blum, Alain .
EUROPEAN RADIOLOGY, 2012, 22 (02) :295-301
[5]   A comparison of radiation doses between state-of-the-art multislice CT coronary angiography with iterative reconstruction, multislice CT coronary angiography with standard filtered back-projection and invasive diagnostic coronary angiography [J].
Gosling, O. ;
Loader, R. ;
Venables, P. ;
Roobottom, C. ;
Rowles, N. ;
Bellenger, N. ;
Morgan-Hughes, G. .
HEART, 2010, 96 (12) :922-926
[6]   Iterative Reconstruction Technique for Reducing Body Radiation Dose at CT: Feasibility Study [J].
Hara, Amy K. ;
Paden, Robert G. ;
Silva, Alvin C. ;
Kujak, Jennifer L. ;
Lawder, Holly J. ;
Pavlicek, William .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2009, 193 (03) :764-771
[7]   THE EXPONENTIAL EDGE-GRADIENT EFFECT IN X-RAY COMPUTED-TOMOGRAPHY [J].
JOSEPH, PM ;
SPITAL, RD .
PHYSICS IN MEDICINE AND BIOLOGY, 1981, 26 (03) :473-487
[8]   In Vitro Evaluation of Metallic Coronary Artery Stents With 64-MDCT Using an ECG-Gated Cardiac Phantom: Relationship Between In-Stent Visualization, Stent Type, and Heart Rate [J].
Kerl, J. Matthias ;
Schoepf, U. Joseph ;
Vogl, Thomas J. ;
Ackermann, Hanns ;
Vogt, Sebastian ;
Costello, Philip ;
Herzog, Christopher .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2010, 194 (03) :W256-W262
[9]   Meta-Analysis of Diagnostic Efficacy of 64-Slice Computed Tomography in the Evaluation of Coronary In-Stent Restenosis [J].
Kumbhani, Dharam J. ;
Ingelmo, Christopher P. ;
Schoenhagen, Paul ;
Curtin, Ronan J. ;
Flamm, Scott D. ;
Desai, Milind Y. .
AMERICAN JOURNAL OF CARDIOLOGY, 2009, 103 (12) :1675-1681
[10]  
Min James K, 2009, J Cardiovasc Comput Tomogr, V3, P246, DOI 10.1016/j.jcct.2009.06.006