Performance and Future Upgrades of the CMS Drift Tube Muon Detector

被引:0
|
作者
Redondo, D. D. [1 ]
机构
[1] CIEMAT, Particle Phys Div, Madrid, Spain
关键词
LHC; CMS; gaseous detectors; drift chambers; muon;
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
A key component of the CMS (Compact Muon Solenoid) experiment is its muon system. The tracking and triggering of muons in the central region relies on Drift Tube (DT) chambers. The DT system keeps evolving in order to cope with long term operational challenges, as well as future constraints for rate reduction imposed by expected increases of LHC luminosity, while maintaining the highest possible efficiency. The main system improvements implemented, as well as the current performance results from the detector are described here, confirming the satisfactory operation of DT. Also, the present design, status and plans for future DT upgrades are reviewed in this document.
引用
收藏
页数:4
相关论文
共 50 条
  • [1] Irradiation aging of the CMS Drift Tube muon detector
    Redondo Ferrero, D. D.
    Abbiendi, G.
    Alcaraz Maestre, J.
    Alvarez Fernandez, A.
    Alvarez Gonzalez, B.
    Amapane, N.
    Bachiller, I.
    Barcala, J. M.
    Barcellan, L.
    Battilana, C.
    Bellato, M.
    Bencze, G.
    Benettoni, M.
    Beni, N.
    Benvenuti, A.
    Blanco Ramos, L. C.
    Boletti, A.
    Bragagnolo, A.
    Brochero Cifuentes, J. A.
    Cafaro, V.
    Calderon, A.
    Calvo, E.
    Cappati, A.
    Carlin, R.
    Carrillo Montoya, C. A.
    Caturan, S.
    Cavallo, F. R.
    Cela Ruiz, J. M.
    Cepeda, M.
    Cerrada, M.
    Chazin Quero, B.
    Checchia, P.
    Ciano, L.
    Colino, N.
    Corti, D.
    Cotto, G.
    Cuevas, J.
    Cuffiani, M.
    Dallavalle, G. M.
    Dattola, D.
    De La Cruz, B.
    De Remigis, P.
    de Troconiz, J. F.
    Erice Cid, C.
    Bedoya, C. F.
    Fabbri, F.
    Fanfani, A.
    Fasanella, D.
    Fernandez Manteca, P.
    Fernandez Menendez, J.
    RADIATION PHYSICS AND CHEMISTRY, 2020, 172
  • [2] 40 MHz triggerless readout of the CMS Drift Tube muon detector
    Migliorini, M.
    Pazzini, J.
    Triossi, A.
    Zanetti, M.
    JOURNAL OF INSTRUMENTATION, 2024, 19 (02)
  • [3] Performance of the drift tubes for the barrel muon chambers of the CMS detector at LHC
    Universita di Padova, Padova, Italy
    Nucl Instrum Methods Phys Res Sect A, 2 (133-147):
  • [4] Performance of the drift tubes for the barrel muon chambers of the CMS detector at LHC
    Lippi, I
    NUCLEAR PHYSICS B, 1997, : 237 - 244
  • [5] Performance of the drift tubes for the barrel muon chambers of the CMS detector at LHC
    Benettoni, M
    Benvenuti, A
    Berdugo, J
    Bethke, S
    Cerrada, M
    Colino, N
    De Giorgi, M
    De Min, A
    Dosselli, U
    Fanin, C
    Fehr, B
    Gasparini, F
    Giantin, R
    Giordano, V
    Guerzoni, M
    de Guevara, PL
    Lippi, I
    Marcellini, S
    Martinelli, R
    Mazzucato, F
    Meneguzzo, A
    Mocholi, J
    Montanari, A
    Navarria, FL
    Pegoraro, M
    Sancho, AJP
    Reithler, H
    Romero, L
    Ronchese, P
    Rossi, AM
    Rovelli, T
    Sartori, P
    Schwarthoff, H
    Tano, V
    Teykal, H
    Vandenhirtz, J
    Wagner, H
    Zotto, P
    Zumerle, G
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1998, 410 (02): : 133 - 147
  • [6] Performance tests of the Drift Tube Muon chambers for the CMS experiment at the LHC
    Cavallo, FR
    NUCLEAR PHYSICS B-PROCEEDINGS SUPPLEMENTS, 2003, 125 : 206 - 211
  • [7] Near future upgrades of the CMS pixel detector
    Kumar, A.
    JOURNAL OF INSTRUMENTATION, 2015, 10
  • [8] The drift tubes of the barrel-muon detector of CMS
    Gasparini, F
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1996, 384 (01): : 211 - 213
  • [9] Construction and Performance of full scale GEM prototypes for future upgrades of the CMS or Muon system
    Abbrescia, M.
    Colaleo, A.
    de Robertis, G.
    Loddo, F.
    Maggi, M.
    Nuzzo, S.
    Tupputi, S. A.
    Ban, Y.
    Cai, J.
    Teng, H.
    Mohapatra, A.
    Moulik, T.
    Gutierrez, A.
    Karchin, P. E.
    Benussi, L.
    Bianco, S.
    Colafranceschi, S.
    Piccolo, D.
    Raffone, G.
    Saviano, G.
    Abbaneo, D.
    Aspell, P.
    Bally, S.
    Bos, J.
    Chatelain, J. P.
    Christiansen, J.
    Garcia, A. Conde
    David, E.
    De Oliveira, R.
    Pinto, S. Duarte
    Ferry, S.
    Formenti, F.
    Marchloro, A.
    Postema, H.
    Rodrigues, A.
    Ropelewski, L.
    Sharma, A.
    Smilkjovic, N.
    Zientek, M.
    Marinov, A.
    Tytgat, M.
    Zaganidis, N.
    Gnanvo, K.
    Hohlmann, M.
    Staib, M. J.
    Magazzu, G.
    Oliveri, E.
    Turini, N.
    Bunkowski, K.
    Fruboes, T.
    ASTROPARTICLE, PARTICLE, SPACE PHYSICS AND DETECTORS FOR PHYSICS APPLICATIONS, 2012, 7 : 554 - 558
  • [10] The Drift Tube Barrel Muon Trigger at the CMS experiment
    de Troconiz, J. F.
    NUCLEAR PHYSICS B-PROCEEDINGS SUPPLEMENTS, 2007, 172 : 171 - 173