Contrast-enhanced blood-pool MR angiography with optimized iron oxides: Effect of size and dose on vascular contrast enhancement in rabbits

被引:106
作者
Allkemper, T
Bremer, C
Matuszewski, L
Ebert, W
Reimer, P
机构
[1] Univ Hosp Munster, Dept Clin Radiol, D-48129 Munster, Germany
[2] Schering AG, D-1000 Berlin, Germany
关键词
contrast media; comparative studies; experimental studies; gadolinium; magnetic resonance (MR); vascular studies;
D O I
10.1148/radiol.2232010241
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
PURPOSE: To investigate intravascular enhancement of bolus-injectable small and ultrasmall superparamagnetic iron oxides (USP10s) of different particle sizes and relaxivities for first-pass and blood-pool magnetic resonance (MR) angiography. MATERIALS AND METHODS: Iron oxides with different particle sizes (hydrodynamic diameters, 21, 33, 46, and 65 nm) were bolus injected intravenously at three doses (10, 20, and 40 mumol per kilogram body weight). An extracellular contrast agent (gadopentetate dimeglumine) served as a control. MR angiography was performed multiple times after intravenous injection (5-120 minutes and 24 hours later). Signal enhancement was calculated from signal intensity measurements in the abdominal aorta and renal and iliac arteries. RESULTS: Highest enhancement was seen during the first pass with all contrast agents. USPIO enhancement in the abdominal aorta increased significantly with decreasing particle size (65 nm vs 33 nm, 65 nm vs 21 nm; P < .01). CONCLUSION: The smallest iron oxide provided signal enhancement comparable with that of gadopentetate dimeglumine at 40 mumol iron per kilogram for first-pass investigations, with prolonged signal enhancement up to 25 minutes, allowing multiple measurements after injection of a single bolus. (C) RSNA, 2002.
引用
收藏
页码:432 / 438
页数:7
相关论文
共 50 条
  • [1] DYNAMIC CONTRAST-ENHANCED MR-IMAGING OF THE UPPER ABDOMEN - ENHANCEMENT PROPERTIES OF GADOBUTROL, GADOLINIUM-DTPA-POLYLYSINE, AND GADOLINIUM-DTPA-CASCADE-POLYMER
    ADAM, G
    NEUERBURG, J
    SPUNTRUP, E
    MUHLER, A
    SCHERER, K
    GUNTHER, RW
    [J]. MAGNETIC RESONANCE IN MEDICINE, 1994, 32 (05) : 622 - 628
  • [2] Pulmonary MR angiography with ultrasmall superparamagnetic iron oxide particles as a blood pool agent and a navigator echo for respiratory gating:: Pilot study
    Ahlström, KH
    Johansson, LO
    Rodenburg, JB
    Ragnarsson, AS
    Åkeson, P
    Börseth, A
    [J]. RADIOLOGY, 1999, 211 (03) : 865 - 869
  • [3] BIODISTRIBUTION OF AN ULTRASMALL SUPERPARAMAGNETIC IRON-OXIDE COLLOID, BMS-180549, BY DIFFERENT ROUTES OF ADMINISTRATION
    BENGELE, HH
    PALMACCI, S
    ROGERS, J
    JUNG, CW
    CRENSHAW, J
    JOSEPHSON, L
    [J]. MAGNETIC RESONANCE IMAGING, 1994, 12 (03) : 433 - 442
  • [4] Iron oxide contrast media improve MR-imaging of the portal venous system - An experimental study.
    Bock, JC
    Knollmann, FD
    Teltenkotter, S
    Wlodarczyk, W
    Muhler, A
    Vogl, TJ
    Felix, R
    [J]. ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 1997, 166 (02): : 153 - 158
  • [5] A NEW MACROMOLECULE AS A CONTRAST AGENT FOR MR-ANGIOGRAPHY - PREPARATION, PROPERTIES, AND ANIMAL STUDIES
    BOGDANOV, AA
    WEISSLEDER, R
    FRANK, HW
    BOGDANOVA, AV
    NOSSIF, N
    SCHAFFER, BK
    TSAI, E
    PAPISOV, MI
    BRADY, TJ
    [J]. RADIOLOGY, 1993, 187 (03) : 701 - 706
  • [6] RATIONALE AND APPLICATIONS FOR MACROMOLECULAR GD-BASED CONTRAST AGENTS
    BRASCH, RC
    [J]. MAGNETIC RESONANCE IN MEDICINE, 1991, 22 (02) : 282 - 287
  • [7] Comparison of two blood pool contrast agents for 0.5-T MR angiography: Experimental study in rabbits
    Clarke, SE
    Weinmann, HJ
    Dai, EB
    Lucas, AR
    Rutt, BK
    [J]. RADIOLOGY, 2000, 214 (03) : 787 - 794
  • [8] Fleiss JL, 1981, STATISTICAL METHODS, P211, DOI DOI 10.2307/2530193
  • [9] ENHANCEMENT OF MR-ANGIOGRAPHY WITH IRON-OXIDE - PRELIMINARY STUDIES IN WHOLE-BLOOD PHANTOM AND IN ANIMALS
    FRANK, H
    WEISSLEDER, R
    BRADY, TJ
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 1994, 162 (01) : 209 - 213
  • [10] Steady-state and dynamic MR angiography with MS-325: Initial experience in humans
    Grist, TM
    Korosec, FR
    Peters, DC
    Witte, S
    Walovitch, RC
    Dolan, RP
    Bridson, WE
    Yucel, EK
    Mistretta, CA
    [J]. RADIOLOGY, 1998, 207 (02) : 539 - 544