Performance evaluation of a vertical U-tube ground heat exchanger using a numerical simulation approach

被引:0
|
作者
Hu, Pingfang [1 ]
Yu, Zhongyi [2 ]
Lei, Fei [1 ]
Zhu, Na [1 ]
Sun, Qiming [1 ]
Yuan, Xudong [1 ]
机构
[1] Huazhong Univ Sci & Technol, Sch Environm Sci & Engn, Wuhan 430074, Peoples R China
[2] CITIC Gen Inst Architectural Design & Res Co Ltd, Wuhan 430010, Peoples R China
来源
基金
中国国家自然科学基金;
关键词
ground heat exchanger; ground source heat pump; thermal effectiveness coefficient; numerical model; BOREHOLE; PILE;
D O I
10.4028/www.scientific.net/AMR.724-725.909
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
A vertical U-tube ground heat exchanger can be utilized to exchange heat with the soil in ground source heat pump systems. The outlet temperature of the working fluid through the U-tube not only accounts for heat transfer capacity of a ground heat exchanger, but also greatly affects the operational efficiency of heat pump units, which is an important characteristic parameter of heat transfer process. It is quantified by defining a thermal effectiveness coefficient. The performance evaluation is performed with a three dimensional numerical model using a finite volume technique. A dynamic simulation was conducted to analyze the thermal effectiveness as a function of soil thermal properties, backfill material properties, separation distance between the two tube legs, borehole depth and flow velocity of the working fluid. The influence of important characteristic parameters on the heat transfer performance of vertical U-tube ground heat exchangers is investigated, which may provide the references for the design of ground source heat pump systems in practice.
引用
收藏
页码:909 / +
页数:2
相关论文
共 50 条
  • [21] Comparison of vertical U-tube ground heat exchanger thermal resistance calculation methods
    Chen, Chao
    Wang, Yong-Fei
    Ren, Yan
    Chen, Jiang
    Han, Yun-Quan
    Wang, Chun-Xue
    Hunan Daxue Xuebao/Journal of Hunan University Natural Sciences, 2009, 36 (SUPPL. 2): : 58 - 62
  • [22] A two-region simulation model of vertical U-tube ground heat exchanger and its experimental verification
    Yang, Weibo
    Shi, Mingheng
    Liu, Guangyuan
    Chen, Zhenqian
    APPLIED ENERGY, 2009, 86 (10) : 2005 - 2012
  • [23] Thermal performance of a single U-tube ground heat exchanger: A parametric study
    Mousavi Ajarostaghi, Seyed Soheil
    Javadi, Hossein
    Mousavi, Seyed Sina
    Poncet, Sebastien
    Pourfallah, Mohsen
    JOURNAL OF CENTRAL SOUTH UNIVERSITY, 2021, 28 (11) : 3580 - 3598
  • [24] Numerical simulation on heat transfer performance of vertical U-tube with different borehole fill materials
    Fang Liu
    Tao Guo
    Yong Wang
    Miao-cheng Weng
    Journal of Central South University of Technology, 2006, 13 : 234 - 237
  • [25] Numerical simulation on heat transfer performance of vertical U-tube with different borehole fill materials
    Liu, Fang
    Guo, Tao
    Wang, Yong
    Weng, Miao-cheng
    JOURNAL OF CENTRAL SOUTH UNIVERSITY OF TECHNOLOGY, 2006, 13 (03): : 234 - 237
  • [26] Heat extraction characteristics of a vertical U-tube downhole heat exchanger
    Department of Mechanical Engineering, Akita University, 1-1 Tegatagakuen-cho, Akita-shi, Akita, 010-8502, Japan
    Nihon Kikai Gakkai Ronbunshu, B, 2008, 5 (1145-1153): : 1145 - 1153
  • [27] Simulation study on the thermal performance of vertical U-tube heat exchangers for ground source heat pump system
    Pu, Liang
    Qi, Di
    Li, Kang
    Tan, Hongbo
    Li, Yanzhong
    APPLIED THERMAL ENGINEERING, 2015, 79 : 202 - 213
  • [28] Simulation and experimental analysis of optimal buried depth of the vertical U-tube ground heat exchanger for a ground-coupled heat pump system
    Chen, Jinhua
    Xia, Lei
    Li, Baizhan
    Mmereki, Daniel
    RENEWABLE ENERGY, 2015, 73 : 46 - 54
  • [29] Effect of buried depth on thermal performance of a vertical U-tube underground heat exchanger
    Yang, Li
    Zhang, Bo
    Klemes, Jiri Jaromir
    Liu, Jie
    Song, Meiyu
    Wang, Jin
    OPEN PHYSICS, 2021, 19 (01): : 327 - 330
  • [30] Thermal interference of adjacent legs in a vertical U-tube heat exchanger for a ground-coupled heat pump
    Muraya, NK
    ONeal, DL
    Heffington, WM
    ASHRAE TRANSACTIONS 1996, VOL 102, PT 2, 1996, 102 : 12 - 21