Toxicologic profile of iobitridol, a new nonionic low-osmolality contrast medium

被引:0
|
作者
Donadieu, AM [1 ]
Idee, JM [1 ]
Doucet, D [1 ]
Legros, A [1 ]
Penati, S [1 ]
NainDitDucret, M [1 ]
Marmion, F [1 ]
Bonnemain, B [1 ]
机构
[1] LAB GUERBET,RES CTR,AULNAY SOUS BOIS,FRANCE
关键词
contrast media; iobitridol; toxicology; experimental studies;
D O I
暂无
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: The toxicologic profile of iobitridol, a new nonionic low-osmolality contrast medium, was evaluated in compliance with the current regulatory requirements in Europe, the USA and Canada. Material and Methods: The toxicity of iobitridol was tested following acute or repeated i.v. administration in several different species (mouse, rat, dog); single oral administration in the mouse and intracisternal injection in the rat. Furthermore, teratogenicity and mutagenicity were evaluated in the rat and rabbit. Local perivenous toxicity was assessed in the rabbit. Results: The acute toxicity of iobitridol in the mouse is equivalent to that of iohexol, a reference product tested under the same conditions. Chronic administration (daily i.v. injection over 4 weeks) in the rat and dog did not demonstrate any particular toxicity for iobitridol. It should be noted that, unlike iohexol, iobitridol did not provoke any vacuolization of the renal tubular cells in the rat following repeated injections, Furthermore, this contrast agent did not show any teratogenic or mutagenic potential. The typical local inflammatory signs observed following perivenous injection in the rabbit were low in intensity and reversible. Conclusion: The toxicologic profile of iobitridol appears to be favorable and does not show any particular risk for clinical use under the usual indications of water-soluble iodinated contrast agents.
引用
收藏
页码:17 / 24
页数:8
相关论文
共 46 条
  • [31] Deaths related to iodinated contrast media reported spontaneously to the US Food and Drug Administration, 1978-1994: Effect of the availability of low-osmolality contrast medial
    Spring, DB
    Bettmann, MA
    Barkan, HE
    RADIOLOGY, 1997, 204 (02) : 333 - 337
  • [32] Safety Analysis of Iobitridol as a Nonionic Contrast Medium A Postmarketing Multicenter Surveillance Study With 94,960 Patients Almost 20 Years After Introduction
    Gorodetski, Boris
    Heine, Oliver
    Wolf, Michael
    Collettini, Federico
    Hamm, Bernd
    Darmon-Kern, Elisabeth
    Penzkofer, Tobias
    INVESTIGATIVE RADIOLOGY, 2020, 55 (03) : 144 - 152
  • [33] Clinical characteristics of adverse reactions to nonionic low osmolality contrast media in patients transferred from the CT room to the emergency room
    Ha, Sang Ook
    Kim, Dae Yong
    Sohn, You Dong
    SPRINGERPLUS, 2016, 5
  • [34] INFLUENCE OF LOW OSMOLALITY CONTRAST-MEDIA ON ELECTROPHYSIOLOGY AND HEMODYNAMICS IN CORONARY ANGIOGRAPHY - DIFFERENCES BETWEEN AN IONIC (IOXAGLATE) AND A NONIONIC (IOHEXOL) AGENT
    VIKMO, H
    FOLLING, M
    BARTH, P
    NORDREHAUG, JE
    BJORKHAUG, A
    ROSLAND, GA
    CATHETERIZATION AND CARDIOVASCULAR DIAGNOSIS, 1990, 21 (04): : 221 - 226
  • [35] Nonionic compact dimers: A new generation of isosmolar iodinated contrast media with low viscosity
    Petta, M
    Raynal, I
    Bourrinet, P
    Vadel, M
    Meyer, D
    ACADEMIC RADIOLOGY, 1998, 5 (01) : 41 - 48
  • [36] Influence of a new monomerio nonionic radiographic contrast medium (Iobitridol-350 versus NaCl) on cutaneous microcirculation: Single-center, prospective, randomized, double-blind phase IV study in parallel group design
    Bach, R
    Gerk, U
    Mrowietz, C
    Jung, F
    MICROVASCULAR RESEARCH, 2000, 60 (03) : 193 - 200
  • [37] CONTRAST RADIOGRAPHY IN SMALL-BOWEL OBSTRUCTION - A RANDOMIZED TRIAL OF BARIUM-SULFATE AND A NONIONIC LOW-OSMOLAR CONTRAST-MEDIUM
    SANDIKCIOGLU, TG
    TORPMADSEN, S
    PEDERSEN, IK
    RAASCHOU, K
    MYGIND, T
    THOMSEN, HS
    ACTA RADIOLOGICA, 1994, 35 (01) : 62 - 64
  • [38] IODIXANOL, A NEW NONIONIC, DIMERIC CONTRAST-MEDIUM IN CARDIOANGIOGRAPHY - A DOUBLE-MASKED, PARALLEL COMPARISON WITH IOPROMIDE
    MANNINEN, H
    TAHVANAINEN, K
    BORCH, KW
    WALLEN, T
    SOIMAKALLIO, S
    MATSI, P
    SUHONEN, M
    EUROPEAN RADIOLOGY, 1995, 5 (04) : 364 - 370
  • [39] COMPARISON OF A LOW OSMOLARITY NONIONIC RADIOGRAPHIC CONTRAST AGENT WITH A STANDARD MEDIUM ON RENAL-FUNCTION IN CYANOTIC AND NORMAL DOGS
    PRIDJIAN, AK
    BOVE, EL
    BEEKMAN, RH
    LUPINETTI, FM
    CATHETERIZATION AND CARDIOVASCULAR DIAGNOSIS, 1994, 31 (01): : 90 - 93
  • [40] CORONARY ANGIOPLASTY USING A LOW-OSMOLAR NONIONIC CONTRAST-MEDIUM - A RETROSPECTIVE ANGIOGRAPHIC AND CLINICAL-EVALUATION
    KJELLEVAND, TO
    KLOW, NE
    VATNE, K
    LAERUM, E
    VIK, H
    ENDRESEN, K
    LEVORSTAD, K
    ACTA RADIOLOGICA, 1995, 36 (01) : 54 - 57