Toxicologic profile of iobitridol, a new nonionic low-osmolality contrast medium

被引:0
|
作者
Donadieu, AM [1 ]
Idee, JM [1 ]
Doucet, D [1 ]
Legros, A [1 ]
Penati, S [1 ]
NainDitDucret, M [1 ]
Marmion, F [1 ]
Bonnemain, B [1 ]
机构
[1] LAB GUERBET,RES CTR,AULNAY SOUS BOIS,FRANCE
关键词
contrast media; iobitridol; toxicology; experimental studies;
D O I
暂无
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: The toxicologic profile of iobitridol, a new nonionic low-osmolality contrast medium, was evaluated in compliance with the current regulatory requirements in Europe, the USA and Canada. Material and Methods: The toxicity of iobitridol was tested following acute or repeated i.v. administration in several different species (mouse, rat, dog); single oral administration in the mouse and intracisternal injection in the rat. Furthermore, teratogenicity and mutagenicity were evaluated in the rat and rabbit. Local perivenous toxicity was assessed in the rabbit. Results: The acute toxicity of iobitridol in the mouse is equivalent to that of iohexol, a reference product tested under the same conditions. Chronic administration (daily i.v. injection over 4 weeks) in the rat and dog did not demonstrate any particular toxicity for iobitridol. It should be noted that, unlike iohexol, iobitridol did not provoke any vacuolization of the renal tubular cells in the rat following repeated injections, Furthermore, this contrast agent did not show any teratogenic or mutagenic potential. The typical local inflammatory signs observed following perivenous injection in the rabbit were low in intensity and reversible. Conclusion: The toxicologic profile of iobitridol appears to be favorable and does not show any particular risk for clinical use under the usual indications of water-soluble iodinated contrast agents.
引用
收藏
页码:17 / 24
页数:8
相关论文
共 46 条
  • [21] POLYARTHROPATHY - A DELAYED-REACTION TO LOW-OSMOLALITY ANGIOGRAPHIC CONTRAST-MEDIUM IN PATIENTS WITH END-STAGE RENAL-DISEASE
    DONNELLY, PK
    WILLIAMS, B
    WATKIN, EM
    EUROPEAN JOURNAL OF RADIOLOGY, 1993, 17 (02) : 130 - 132
  • [22] Analysis of the factors influencing the osmolality of eight monomeric nonionic iodinated contrast medium molecules
    Violon, D
    INVESTIGATIVE RADIOLOGY, 1997, 32 (11) : 684 - 689
  • [23] ROLE OF LOW-OSMOLALITY CONTRAST-MEDIA IN THROMBOEMBOLIC COMPLICATIONS - SCANNING ELECTRON-MICROSCOPY STUDY
    CASALINI, E
    RADIOLOGY, 1992, 183 (03) : 741 - 744
  • [24] LOW-OSMOLALITY CONTRAST-MEDIA - DOSAGE COMPARISON OF IOVERSOL AND IOHEXOL FOR CRANIAL COMPUTED-TOMOGRAPHY
    KUHN, MJ
    LONG, SD
    DESIO, MA
    COMPUTERIZED MEDICAL IMAGING AND GRAPHICS, 1991, 15 (06) : 403 - 406
  • [25] IOXILAN, A 3RD GENERATION LOW OSMOLALITY NONIONIC CONTRAST-MEDIUM - SYSTEMIC AND RENAL HEMODYNAMIC-EFFECTS
    KATZBERG, RW
    DONAHUE, LA
    MORRIS, TW
    VENTURA, JA
    KRUTCHEN, AE
    PROSKIN, HM
    SOVAK, M
    COS, LR
    INVESTIGATIVE RADIOLOGY, 1990, 25 (01) : 46 - 51
  • [26] ALLERGIC-TYPE ADVERSE REACTIONS TO LOW-OSMOLALITY CONTRAST-MEDIA IN PATIENTS WITH A HISTORY OF ALLERGY OR ASTHMA
    SIMON, MR
    INVESTIGATIVE RADIOLOGY, 1995, 30 (05) : 285 - 290
  • [27] Incidence and Risk Factors of Nausea and Vomiting after Exposure to Low-Osmolality Iodinated Contrast Media in Children: A Focus on Preparative Fasting
    Ha, Ji Young
    Choi, Young Hun
    Cho, Yeon Jin
    Lee, Seunghyun
    Lee, Seul Bi
    Choi, Gayoung
    Cheon, Jung Eun
    Kim, Woo Sun
    KOREAN JOURNAL OF RADIOLOGY, 2020, 21 (10) : 1178 - 1186
  • [28] Effect of Extrinsic Warming of Low-Osmolality CT Contrast Media (Iohexol 350) on Extravasations and Patient Reaction Rates: A Retrospective Study
    Basharat, Noor F.
    Ranganathan, Karthik
    Kang, Paul T.
    Gridley, Daniel G.
    Roh, Albert T.
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2022, 218 (01) : 174 - 179
  • [29] TOLERANCE OF A NEW NONIONIC CONTRAST-MEDIUM DURING HEART CATHETERIZATION
    MEYER, GP
    TRAPPE, HJ
    JOST, S
    RAFFLENBEUL, W
    WENZLAFF, P
    LICHTLEN, P
    ARZNEIMITTELFORSCHUNG-DRUG RESEARCH, 1993, 43-2 (08): : 932 - 934
  • [30] A COMPARISON OF HEPARINIZED LOW OSMOLALITY IONIC AND NONIONIC CONTRAST-MEDIA IN 500 PATIENTS UNDERGOING CARDIAC ANGIOGRAPHY
    FELDMAN, RL
    CLINICAL CARDIOLOGY, 1990, 13 (11) : 794 - 796