Effects of heparin coating of cardiopulmonary bypass circuits on in vitro oxygen free radical production during coronary bypass surgery

被引:14
|
作者
Bozdayi, M
Borowiec, J
Nilsson, L
Venge, P
Thelin, S
Hansson, HE
机构
[1] UNIV UPPSALA HOSP,DEPT THORAC & CARDIOVASC SURG,S-75185 UPPSALA,SWEDEN
[2] UNIV UPPSALA HOSP,DEPT CLIN CHEM,S-75185 UPPSALA,SWEDEN
关键词
cardiopulmonary bypass; heparin coating; oxygen free radicals; granulocyte-derived enzymes;
D O I
10.1111/j.1525-1594.1996.tb04588.x
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
During cardiopulmonary bypass (CPB) oxygen free radicals (OFR) are formed, which can mediate reactions damaging tissue components. Blood contact with artificial sufaces during CPB leads to an activation of leukocytes, which are one of the sources of the OFR. Heparin coating of the CPB circuit reduces granulocyte activation. In the present study, the heparin-coated circuits with nancoated cardiotomy reservoirs (Group HC) were compared with noncoated, otherwise similar CPB sets (Group C). In each group, 8 patients were operated on for coronary revascularization. The release of granulocyte granule proteins myeloperoxidase (MPO) and lactoferrin (LF) was evaluated. Production of OFR in the whole blood and in the granulocyte suspension were measured by chemiluminescence (CL), In both groups the whole blood CL declined during CPB. The whole blood CL induced by serum-opsonized zymosan, when enhanced by luminal, was significantly lower in Group HC at 45 min after CPB start (68 +/- 6% of initial values in Group HC vs. 87 +/- 6% in Group C, mean +/- SEM) and 30 min after protaminization (54 +/- 6% of initial values in Group HC vs. 72 +/- 6% in Group C, mean +/- SEM), and CL was significantly higher in Group HC at CPB end (83 +/- 5% of initial values in Group HC vs. 67 +/- 5% in Group C, mean +/- SEM) when enhanced by lucigenin. CL of isolated granulocytes showed no significant differences between the groups. Release of MPO at CPB end and of LF 45 min after start of CPB and at CPB end were significantly lower in the heparin-coated CPB circuits.
引用
收藏
页码:1008 / 1016
页数:9
相关论文
共 50 条
  • [31] Cell activation and thrombin generation in heparin bonded cardiopulmonary bypass circuits using a novel in vitro model
    Bannan, S
    Danby, A
    Cowan, D
    Ashraf, S
    Gesinde, M
    Martin, P
    EUROPEAN JOURNAL OF CARDIO-THORACIC SURGERY, 1997, 12 (02) : 268 - 275
  • [32] Haemostasis at low heparin dosage during cardiopulmonary bypass with heparin-coated circuits in pigs (vol 31, pg 275, 1997)
    Bagge, L
    Borowiec, JW
    Thelin, S
    Hultman, J
    SCANDINAVIAN CARDIOVASCULAR JOURNAL, 1997, 31 (06)
  • [33] Application of a pharmacokinetics-pharmacodynamics approach to the free propofol plasma levels during coronary artery bypass grafting surgery with hypothermic cardiopulmonary bypass
    Silva-Filho, Carlos R.
    Barbosa, Ricardo Antonio G.
    Silva-, Carlindo V., Jr.
    Malbouisson, Luiz M. S.
    Carmona, Maria Jose C.
    Jorge-Santos, Silvia Regina C.
    CLINICS, 2018, 73
  • [34] Effect of cardiopulmonary bypass on tissue injury markers and endothelial activation during coronary artery bypass graft surgery
    Nair, S.
    Iqbal, K.
    Phadke, M.
    Jadhav, U. E.
    Khandekar, J.
    Khandeparkar, J. M. S.
    JOURNAL OF POSTGRADUATE MEDICINE, 2012, 58 (01) : 8 - 13
  • [35] Troponin as a marker of myocardial damage during coronary surgery with and without cardiopulmonary bypass
    Piacenza, AE
    Cacheda, JH
    Badaracco, JR
    Benetti, FJ
    JOURNAL OF CARDIOVASCULAR SURGERY, 2001, 42 (06) : 709 - 712
  • [36] Effects of temperature strategy during cardiopulmonary bypass on cerebral oxygen balance
    Ip-Yam, PC
    Thomas, SD
    Jackson, M
    Rashid, A
    Behl, S
    JOURNAL OF CARDIOVASCULAR SURGERY, 2000, 41 (01) : 1 - 6
  • [37] The effects of cardiopulmonary bypass on pulmonary function during robotic cardiac surgery
    Wang, G.
    Xiao, S.
    Gao, C.
    PERFUSION-UK, 2015, 30 (03): : 213 - 218
  • [38] Clinical evaluation of heparin-coated circuits for routine coronary artery bypass grafting surgery:: A prospective randomized study
    Collart, F
    Caus, T
    Pomane, C
    Pellissier, V
    Chi, Y
    Montiès, JR
    Mesana, T
    ARTIFICIAL ORGANS, 2000, 24 (08) : 611 - 613
  • [39] Antiinflammatory effect of heparin-coated circuits with leukocyte-depleting filters in coronary bypass surgery
    Hamada, Y
    Kawachi, K
    Nakata, T
    Kohtani, T
    Takano, S
    Tsunooka, N
    ARTIFICIAL ORGANS, 2001, 25 (12) : 1004 - 1008
  • [40] Effects of new polymer-coated extracorporeal circuits on biocompatibility during cardiopulmonary bypass
    Saito, N
    Motoyama, S
    Sawamoto, J
    ARTIFICIAL ORGANS, 2000, 24 (07) : 547 - 554