Diagnostic accuracy of interleukin 27 for tuberculous pleural effusion: two prospective studies and one meta-analysis

被引:57
作者
Wang, Wen [1 ,2 ]
Zhou, Qiong [3 ]
Zhai, Kan [1 ,2 ]
Wang, Yao [1 ,2 ]
Liu, Jing-Yuan [3 ]
Wang, Xiao-Juan [1 ,2 ]
Wang, Zhen [1 ,2 ]
Zhang, Jian-Chu [3 ]
Tong, Zhao-Hui [1 ,2 ]
Shi, Huan-Zhong [1 ,2 ]
机构
[1] Capital Med Univ, Beijing Inst Resp Med, Dept Resp & Crit Care Med, Beijing, Peoples R China
[2] Capital Med Univ, Beijing Chaoyang Hosp, Beijing, Peoples R China
[3] Huazhong Univ Sci & Technol, Tongji Med Coll, Dept Resp & Crit Care Med, Union Hosp, Wuhan, Hubei, Peoples R China
基金
中国国家自然科学基金;
关键词
adenosine deaminase; interferon-; interleukin; 27; tuberculous pleurisy; MEDICAL THORACOSCOPY; ADENOSINE-DEAMINASE; INTERFERON-GAMMA; SAFETY; TESTS; DISEASE; FLUID; BIAS;
D O I
10.1136/thoraxjnl-2016-209718
中图分类号
R56 [呼吸系及胸部疾病];
学科分类号
摘要
Background Accurate differentiating diagnosis is essential for choosing treatment for exudative pleural effusions. Objective To establish the diagnostic accuracy of interleukin 27 for tuberculous pleural effusion (TPE). Methods First, the concentrations of pleural interleukin 27, interferon-gamma and adenosine deaminase were compared between 51 patients with TPE and 103 with non-TPEs (Beijing cohort), and their diagnostic values were evaluated. These were further verified in another independent population (Wuhan cohort, n=120). In the second part of the study, we performed a meta-analysis. Results With a cut-off value of 591.4 ng/L in the Beijing cohort, the area under the curve, sensitivity, specificity, positive predictive value and negative predictive value of interleukin 27 to diagnose TPE were 0.983 (95% CI 0.947 to 0.997), 96.1% (86.5% to 99.5%), 99.0% (94.7% to 100%), 98.0 (89.4 to 99.9) and 98.1 (93.3 to 99.8), respectively. Excellent diagnostic accuracy of interleukin 27 was also found in the Wuhan cohort and was further confirmed in the meta-analysis. The diagnostic performance of interleukin 27 was comparable to that of interferon-gamma and was more accurate than that of adenosine deaminase. Since the post-test probability of a negative result was always <0.1%, a negative test was considered to exclude TPE in all tuberculosis prevalence settings. Conclusions Interleukin 27 can be used to diagnose TPE in a high prevalence setting, and a negative result can also be reliably used to rule out TPE in all prevalence settings.
引用
收藏
页码:240 / 247
页数:8
相关论文
共 43 条
[41]  
Yang WH, 2012, PLOS ONE, V7, DOI [10.1371/journal.pone.0045233, 10.1371/journal.pone.0046789, 10.1371/journal.pone.0053429]
[42]   Diagnostic accuracy of T-cell interferon-γ release assays in tuberculous pleurisy: A meta-analysis [J].
Zhou, Qiong ;
Chen, Yi-Qiang ;
Qin, Shou-Ming ;
Tao, Xiao-Nan ;
Xin, Jian-Bao ;
Shi, Huan-Zhong .
RESPIROLOGY, 2011, 16 (03) :473-480
[43]  
ZWEIG MH, 1993, CLIN CHEM, V39, P561