Derating of asymmetric three-phase transformers serving unbalanced nonlinear loads

被引:57
作者
Masoum, Mohammad A. S. [1 ]
Moses, Paul S. [1 ]
Masoum, Amir S. [2 ]
机构
[1] Curtin Univ Technol, Dept Elect & Comp Engn, Perth, WA 6845, Australia
[2] Univ Western Australia, Crawley, WA 6009, Australia
关键词
asymmetry; derating; electric drives; harmonics; nonlinear loads; transformer losses;
D O I
10.1109/TPWRD.2008.923057
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
A new analysis into the steady-state operation and derating of three-phase transformers under nonsinusoidal and asymmetric operating conditions is proposed. The combined effects of transformer core and load asymmetry, nonlinearity, and harmonics, as well as nonsinusoidal input excitation are examined. A time-domain nonlinear model for three-phase three-leg transformers is implemented. Transformer derating is estimated by modeling additional power losses due to harmonics generated by the iron core, nonsinusoidal excitation, and nonlinear (rectifier and electric drive) loading. Laboratory tests are performed to verify simulated waveforms. The contribution of this paper is a nonlinear transformer modeling technique for steady-state operation under unbalanced, asymmetric, and nonsinusoidal operation, capable of computing derating factors.
引用
收藏
页码:2033 / 2041
页数:9
相关论文
共 27 条
[1]  
[Anonymous], C571101986 ANSIIEEE
[2]  
Bishop M. T., 1992, IEEE Computer Applications in Power, V5, P41, DOI 10.1109/67.160046
[3]   Evaluating harmonic-induced transformer heating [J].
Bishop, MT ;
Baranowski, JF ;
Heath, D ;
Benna, SJ .
IEEE TRANSACTIONS ON POWER DELIVERY, 1996, 11 (01) :305-311
[4]   Modeling devices with nonlinear voltage-current characteristics for harmonic studies [J].
Chang, G ;
Hatziadoniu, C ;
Xu, W ;
Ribeiro, P ;
Burch, R ;
Grady, WA ;
Halpin, M ;
Liu, Y ;
Ranade, S ;
Ruthman, D ;
Watson, N ;
Ortmeyer, T ;
Wikston, J ;
Medina, A ;
Testa, A ;
Gardiner, R ;
Dinavahi, V ;
Acram, F ;
Lehn, P .
IEEE TRANSACTIONS ON POWER DELIVERY, 2004, 19 (04) :1802-1811
[5]  
Clua J, 2000, INT C HARMON QUAL PO, P726, DOI 10.1109/ICHQP.2000.897768
[6]  
Damnjanovic A, 2004, 2004 IEEE POWER ENGINEERING SOCIETY GENERAL MEETING, VOLS 1 AND 2, P1416
[7]   Modeling and simulation, and their validation of three-phase transformers with three legs under DC bias [J].
Fuchs, EF ;
You, Y ;
Roesler, DJ .
IEEE TRANSACTIONS ON POWER DELIVERY, 1999, 14 (02) :443-449
[8]   Measurement of Eddy-current loss coefficient PEC-R, derating of single-phase transformers, and comparison with K-factor approach [J].
Fuchs, EF ;
Yildirim, D ;
Grady, WM .
IEEE TRANSACTIONS ON POWER DELIVERY, 2000, 15 (01) :148-154
[9]   Measurement of three-phase transformer derating and reactive power demand under nonlinear loading conditions [J].
Fuchs, EF ;
Lin, DS ;
Martynaitis, J .
IEEE TRANSACTIONS ON POWER DELIVERY, 2006, 21 (02) :665-672
[10]  
FUCHS EF, 1991, IEEE T POWER DELIVER, V6, P174