Dynamic angular three-dimensional measurement of multisegmental thoracolumbar motion in vivo

被引:28
作者
Gercek, Erol [1 ]
Hartmann, Frank [1 ]
Kuhn, Sebastian [1 ]
Degreif, Jurgen [2 ]
Rommens, Pol Maria [1 ]
Rudig, Lothar [3 ]
机构
[1] Johannes Gutenberg Univ Mainz, Clin Trauma Surg, D-55131 Mainz, Germany
[2] Staedt Kliniken, Clin Orthopaed & Trauma Surg, Esslingen, Germany
[3] GPR Klinikum, Clin Trauma Surg, Russelsheim, Germany
关键词
thoracolumbar spine; segmental motion; biomechanics; in vivo measurement;
D O I
10.1097/BRS.0b013e31818096ea
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Study Design. Method validation and in vivo motion segment study. Objective. To determine in healthy subjects in vivo intervertebral segmental kinematics and coupled motion behavior in all 3 planes simultaneously for 3 segments and to evaluate whether these results differ from those in the normal population according to the literature. Summary of Background Data. Few studies have provided a direct invasive approach to investigate segmental kinematics in vivo. Dynamic recordings of 3-dimensional segmental motion patterns of adjacent segments have rarely been reported. To date, no studies have examined the 3-dimensional segmental movements of the thoracolumbar junction in vivo in detail. Methods. K-wires were inserted into the Th11, Th12, L1, and L2 spinous processes of 21 healthy subjects. Ultrasound markers and sensors were attached to the k-wires. Real-time motion data were recorded during standardized ranging exercises. Errors caused by the k-wires, and the static and dynamic accuracy of the system, were considered. Results. Large intersubject variation was found in all of the exercises. The average ranges of motion from Th11 to L2 were 18.7 degrees for flexion-extension, 13.5 degrees for one-sided lateral bending, and 1.8 degrees for one-sided axial rotation. Coupled-motion patterns among the subjects showed a coupled flexion in active lateral bending and a coupled extension in active rotation, but the results were inconsistent for active extension and flexion. Conclusion. This method offered accurate multisegmental dynamic-recording facilities. The dynamic exercises showed high reproducibility. The ranges of motion for extension/flexion and lateral bending differed from those reported in previous studies. The coupling patterns were only partly consistent because of large interindividual variation. The measurement error was comparable with that of other invasive methods.
引用
收藏
页码:2326 / 2333
页数:8
相关论文
共 36 条
  • [1] ALARANTA H, 1994, SCAND J REHABIL MED, V26, P147
  • [2] CONTINUOUS MEASUREMENT OF LUMBAR POSTURE USING FLEXIBLE ELECTROGONIOMETERS
    BOOCOCK, MG
    JACKSON, JA
    BURTON, AK
    TILLOTSON, KM
    [J]. ERGONOMICS, 1994, 37 (01) : 175 - 185
  • [3] Measuring spinal motion in rowers: the use of an electromagnetic device
    Bull, AMJ
    McGregor, AH
    [J]. CLINICAL BIOMECHANICS, 2000, 15 (10) : 772 - 776
  • [4] Effects of posture and structure on three-dimensional coupled rotations in the lumbar spine - A biomechanical analysis
    Cholewicki, J
    Crisco, JJ
    Oxland, TR
    Yamamoto, I
    Panjabi, MM
    [J]. SPINE, 1996, 21 (21) : 2421 - 2428
  • [5] RADIOLOGIC-DIAGNOSIS OF DEGENERATIVE LUMBAR SPINAL INSTABILITY
    DUPUIS, PR
    YONGHING, K
    CASSIDY, JD
    KIRKALDYWILLIS, WH
    [J]. SPINE, 1985, 10 (03) : 262 - 276
  • [6] DVORAK J, 1991, SPINE, V16, P562
  • [7] Precision measurement of segmental motion from flexion-extension radiographs of the lumbar spine
    Frobin, W
    Brinckmann, P
    Leivseth, G
    Biggemann, M
    Reikeras, O
    [J]. CLINICAL BIOMECHANICS, 1996, 11 (08) : 457 - 465
  • [8] RELATIONSHIP OF THE PELVIC ANGLE TO THE SACRAL ANGLE - MEASUREMENT OF CLINICAL RELIABILITY AND VALIDITY
    GILLIAM, J
    BRUNT, D
    MACMILLAN, M
    KINARD, RE
    MONTGOMERY, WJ
    [J]. JOURNAL OF ORTHOPAEDIC & SPORTS PHYSICAL THERAPY, 1994, 20 (04) : 193 - 199
  • [9] ANALYSIS OF SPINAL AND MUSCULAR-ACTIVITY DURING FLEXION EXTENSION AND FREE LIFTS
    GRACOVETSKY, S
    KARY, M
    LEVY, S
    SAID, RB
    PITCHEN, I
    HELIE, J
    [J]. SPINE, 1990, 15 (12) : 1333 - 1339
  • [10] AN IN VIVO STUDY OF AXIAL ROTATION OF HUMAN THORACOLUMBAR SPINE
    GREGERSEN, GG
    LUCAS, DB
    [J]. JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1967, A 49 (02) : 247 - +