Antiplatelet and Antithrombotic Therapy After Patent Foramen Oval and Atrial Septal Defect Closure

被引:4
作者
Drakopoulou, Maria [1 ]
Soulaidopoulos, Stergios [1 ]
Stathogiannis, Konstantinos [1 ]
Oikonomou, Georgios [1 ]
Papanikolaou, Aggelos [1 ]
Toutouzas, Konstantinos [1 ]
Tousoulis, Dimitrios [1 ]
机构
[1] Athens Univ, Dept Cardiol 1, Sch Med, Hippokrat Hosp, Athens, Greece
关键词
Patent foramen ovale; atrial septal defect; occluder devices; structural heart disease; fossa ovalis; interatrial shunts; TRANSCATHETER CLOSURE; PERCUTANEOUS CLOSURE; MEDICAL THERAPY; PLATELET ACTIVATION; THROMBUS FORMATION; TRANSCRANIAL DOPPLER; DEVICE CLOSURE; OCCLUDER; PATIENT; METAANALYSIS;
D O I
10.2174/1385272824999200427083838
中图分类号
R9 [药学];
学科分类号
1007 ;
摘要
Pathologies of the atrial septum include different interatrial communications varying from patent foramen ovate (PFO) to actual defects. Atrial septal defects (ASDs) may be localized within the fossa (walls such as the secundum type ASD or outside the region of fossa ovalis, such as the ostium primum defect and sinus venosus defect. Over the last decades, the percutaneous closure of interatrial shunts has become a feasible and safe method. During these procedures, the delicate balance between thrombotic risk, device sealing process and bleeding risk is crucial. in this review, we sought to describe current available data on the antiplatelet and antithrombotic management of patients after percutaneous ASD or PFO closure.
引用
收藏
页码:2769 / 2779
页数:11
相关论文
共 72 条
  • [1] Abdi S, 2012, ARCH IRAN MED, V15, P693, DOI 0121511/AIM.009
  • [2] Influence of atrial septal defect anatomy in patient selection and assessment of closure with the Cardioseal device - A three-dimensional transoesophageal echocardiographic reconstruction
    Acar, P
    Saliba, Z
    Bonhoeffer, P
    Aggoun, Y
    Bonnet, D
    Sidi, D
    Kachaner, J
    [J]. EUROPEAN HEART JOURNAL, 2000, 21 (07) : 573 - 581
  • [3] Real-time 3D transoesophageal echocardiography for guiding Amplatzer septal occluder device deployment in an adult patient with atrial septal defect
    Acar, Philippe
    Massabuau, Pierre
    Elbaz, Meyer
    [J]. EUROPEAN JOURNAL OF ECHOCARDIOGRAPHY, 2008, 9 (06): : 822 - 823
  • [4] Meta-Analysis of Transcatheter Closure Versus Medical Therapy for Patent Foramen Ovale in Prevention of Recurrent Neurological Events After Presumed Paradoxical Embolism
    Agarwal, Shikhar
    Bajaj, Navkaranbir Singh
    Kumbhani, Dharam J.
    Tuzcu, E. Murat
    Kapadia, Samir R.
    [J]. JACC-CARDIOVASCULAR INTERVENTIONS, 2012, 5 (07) : 777 - 789
  • [5] Alaeddini Jamshid, 2006, J Invasive Cardiol, V18, P365
  • [6] Patent foramen ovale closure for secondary stroke prevention
    Alkhouli, Mohamad
    Sievert, Horst
    Holmes, David R.
    [J]. EUROPEAN HEART JOURNAL, 2019, 40 (28) : 2339 - +
  • [7] [Anonymous], 2018, Eur Heart J
  • [8] Incidence of thrombus formation on the CardioSEAL and the Amplatzer interatrial closure devices
    Anzai, H
    Child, J
    Natterson, B
    Krivokapich, J
    Fishbein, MC
    Chan, VK
    Tobis, JM
    [J]. AMERICAN JOURNAL OF CARDIOLOGY, 2004, 93 (04) : 426 - 431
  • [9] Does transcatheter closure of patent foramen ovale really "Shut the door?" A prospective study with tanscranial Doppler
    Anzola, GP
    Morandi, E
    Casilli, F
    Onorato, E
    [J]. STROKE, 2004, 35 (09) : 2140 - 2144
  • [10] Transcranial Doppler and risk of recurrence in patients with stroke and patent foramen ovale
    Anzola, GP
    Zavarize, P
    Morandi, E
    Rozzini, L
    Parrinello, G
    [J]. EUROPEAN JOURNAL OF NEUROLOGY, 2003, 10 (02) : 129 - 135