Optimisation analysis of PCM-enhanced opaque building envelope components for the energy retrofitting of office buildings in Mediterranean climates

被引:84
作者
Cascone, Ylenia [1 ]
Capozzoli, Alfonso [1 ]
Perino, Marco [1 ]
机构
[1] Politecn Torino, Dept Energy, TEBE Res Grp, Corso Duca Abruzzi 24, I-10129 Turin, Italy
关键词
Energy retrofitting; Multi-objective optimization; Phase Change Material; Building envelope; Building energy performance; Genetic algorithm; PHASE-CHANGE MATERIALS; COOLING LOAD REDUCTION; MULTIOBJECTIVE OPTIMIZATION; RESIDENTIAL BUILDINGS; GENETIC ALGORITHM; ECONOMIC-ANALYSIS; PERFORMANCE; SIMULATION; DESIGN; MODEL;
D O I
10.1016/j.apenergy.2017.11.081
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
The energy retrofitting of existing buildings is of major importance to reach the energy sustainability target set by the European Union (EU) for 2020. Innovative retrofitting solutions can involve the adoption of Phase Change Materials (PCMs), but an effective use of PCM in buildings requires an appropriate selection of the thermophysical properties, quantity and position of the PCMs. To guarantee a good functioning of a PCM and ensure economic feasibility, an optimisation of PCM use is advisable. In the present paper, multi-objective optimisation analyses for the energy retrofitting of office buildings with PCM-enhanced opaque building envelope components are presented. A retrofitting intervention on either the external or internal side of the opaque envelope was considered, and a maximum of two PCM layers with different melting temperatures were selected and placed in different positions within the wall. Two sets of objective functions were minimised; first, primary energy consumption and global costs, and then the building energy needs for heating and cooling and investment costs. The search variables included the thickness and thermo-physical properties of the PCM layers, the window type, the insulation and internal lining materials, the wall configuration and U-value. In order to provide a robust methodology to drive designers towards an informed choice of the final retrofitting strategy, post-optimisation analyses were additionally carried out to investigate the variable values that led to the optimal solutions. Interesting and non-trivial information was obtained. The optimal thermo-physical properties of PCMs were found to be affected in particular by the operation of the HVAC system.
引用
收藏
页码:929 / 953
页数:25
相关论文
共 81 条
  • [1] A new validated TRNSYS module for simulating latent heat storage walls
    Al-Saadi, Saleh Nasser
    Zhai, Zhiqiang
    [J]. ENERGY AND BUILDINGS, 2015, 109 : 274 - 290
  • [2] Building integration of PCM for natural cooling of buildings
    Alvarez, Servando
    Cabeza, Luisa F.
    Ruiz-Pardo, Alvaro
    Castell, Albert
    Tenorio, Jose Antonio
    [J]. APPLIED ENERGY, 2013, 109 : 514 - 522
  • [3] [Anonymous], 2009, GLOBAL OPTIMIZATION
  • [4] [Anonymous], 1896, Cours dEconomie Politique
  • [5] [Anonymous], 2014, H2020EEB022014 AVANT, P1
  • [6] [Anonymous], 2014, 113002 UNITS
  • [7] [Anonymous], 2012, 152322012 EN
  • [8] [Anonymous], 2014, 103391995 UNI
  • [9] [Anonymous], 2010, Europe 2020-A Strategy for Smart, Sustainable and Inclusive Growth
  • [10] [Anonymous], 2013, THERM 6 3 WINDOW 6 3