Total knee arthroplasties from the origin to navigation: history, rationale, indications

被引:19
作者
Saragaglia, Dominique [1 ]
Rubens-Duval, Brice [1 ]
Gaillot, Julia [1 ]
Lateur, Gabriel [1 ]
Pailhe, Regis [1 ]
机构
[1] Grenoble South Teaching Hosp, Dept Orthopaed Surg & Sport Traumatol, F-38130 Echirolles, France
关键词
Knee; Osteoarthritis; Arthroplasty; Navigation; Computer; FOLLOW-UP; COMPUTER NAVIGATION; ALIGNMENT; PROSTHESIS; REPLACEMENT; METAANALYSIS; OUTCOMES; SYSTEM; OSTEOARTHRITIS; SURVIVAL;
D O I
10.1007/s00264-018-3913-z
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Since the early 1970s, total knee arthroplasties have undergone many changes in both their design and their surgical instrumentation. It soon became apparent that to improve prosthesis durability, it was essential to have instruments which allowed them to be fitted reliably and consistently. Despite increasingly sophisticated surgical techniques, preoperative objectives were only met in 75% of cases, which led to the development, in the early 1990s, in Grenoble (France), of computer-assisted orthopaedic surgery for knee prosthesis implantation. In the early 2000s, many navigation systems emerged, some including pre-operative imagery (CT-based), others using intra-operative imagery (fluoroscopy-based), and yet others with no imagery at all (imageless), which soon became the navigation gold standard. They use an optoelectronic tracker, markers which are fixed solidly to the bones and instruments, and a navigation workstation (computer), with a control system (e.g. pedal). Despite numerous studies demonstrating the benefit of computer navigation in meeting preoperative objectives, such systems have not yet achieved the success they warrant, for various reasons we will be covering in this article. If the latest navigation systems prove to be as effective as the older systems, they should give this type of technology a well-deserved boost.
引用
收藏
页码:597 / 604
页数:8
相关论文
共 66 条
[51]   Results with eight and a half years average follow-up on two hundred and eight e-Motion FP® knee prostheses, fitted using computer navigation for knee osteoarthritis in patients with over ten degrees genu varum [J].
Saragaglia, Dominique ;
Sigwalt, Loic ;
Gaillot, Julia ;
Morin, Vincent ;
Rubens-Duval, Brice ;
Pailhe, Regis .
INTERNATIONAL ORTHOPAEDICS, 2018, 42 (04) :799-804
[52]   Computerised navigation of unicondylar knee prostheses: from primary implantation to revision to total knee arthroplasty [J].
Saragaglia, Dominique ;
Da Silva, Benoit Marques ;
Dijoux, Pierrick ;
Cognault, Jeremy ;
Gaillot, Julia ;
Pailhe, Regis .
INTERNATIONAL ORTHOPAEDICS, 2017, 41 (02) :293-299
[53]   Navigation of the tibial plateau alone appears to be sufficient in computer-assisted unicompartmental knee arthroplasty [J].
Saragaglia, Dominique ;
Picard, Frederic ;
Refaie, Ramsay .
INTERNATIONAL ORTHOPAEDICS, 2012, 36 (12) :2479-2483
[54]   Results of forty two computer-assisted double level osteotomies for severe genu varum deformity [J].
Saragaglia, Dominique ;
Blaysat, Marc ;
Mercier, Numa ;
Grimaldi, Mathieu .
INTERNATIONAL ORTHOPAEDICS, 2012, 36 (05) :999-1003
[55]   Computer-assisted osteotomies for genu varum deformity: which osteotomy for which varus? [J].
Saragaglia, Dominique ;
Mercier, Numa ;
Colle, Pierre-Emmanuel .
INTERNATIONAL ORTHOPAEDICS, 2010, 34 (02) :185-190
[56]   Influence of computer navigation on TKA revision rates [J].
Schnurr, Christoph ;
Guedden, Isabell ;
Eysel, Peer ;
Koenig, Dietmar Pierre .
INTERNATIONAL ORTHOPAEDICS, 2012, 36 (11) :2255-2260
[57]  
Sparmann M, 2004, NAVIGATION ROBOTICS, P319
[58]  
Stiehl J.B., 2004, NAVIG ROBOT TOTAL JT, V22, P226
[59]  
Stindel E, 2002, Comput Aided Surg, V7, P156, DOI 10.3109/10929080209146026
[60]   TIBIOFEMORAL ALIGNMENT AND THE RESULTS OF KNEE REPLACEMENT [J].
TEW, M ;
WAUGH, W .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1985, 67 (04) :551-556