Optimal imaging with adaptive mesh refinement in electrical impedance tomography

被引:29
作者
Molinari, M [1 ]
Blott, BH
Cox, SJ
Daniell, GJ
机构
[1] Univ Southampton, Dept Elect & Comp Sci, Southampton SO17 1BJ, Hants, England
[2] Univ Southampton, Dept Phys & Astron, Southampton SO17 1BJ, Hants, England
关键词
electrical impedance tomography; optimal imaging; image smoothness constraint; adaptive mesh refinement; reconstruction algorithm;
D O I
10.1088/0967-3334/23/1/311
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
In non-linear electrical impedance tomography the goodness of fit of the trial images is assessed by the well-established statistical chi(2) criterion applied to the measured and predicted datasets. Further selection from the range of images that fit the data is effected by imposing an explicit constraint on the form of the image, such as the minimization of the image gradients. In particular, the logarithm of the image gradients is chosen so that conductive and resistive deviations are treated in the same way. In this paper we introduce the idea of adaptive mesh refinement to the 2D problem so that the local scale of the mesh is always matched to the scale of the image structures. This improves the reconstruction resolution so that the image constraint adopted dominates and is not perturbed by the mesh discretization. The avoidance of unnecessary mesh elements optimizes the speed of reconstruction without degrading the resulting images. Starting with a mesh Scale length of the order of the electrode separation it is shown that, for data obtained at presently achievable signal-to-noise ratios of 60 to 80 dB, one or two refinement stages are sufficient to generate high quality images.
引用
收藏
页码:121 / 128
页数:8
相关论文
共 11 条
[1]   A gradient-based optimisation scheme for optical tomography [J].
Arridge, SR ;
Schweiger, M .
OPTICS EXPRESS, 1998, 2 (06) :213-226
[2]   Electrical impedance tomography with compensation for electrode positioning variations [J].
Blott, BH ;
Daniell, GJ ;
Meeson, S .
PHYSICS IN MEDICINE AND BIOLOGY, 1998, 43 (06) :1731-1739
[3]   Nonlinear reconstruction constrained by image properties in electrical impedance tomography [J].
Blott, BH ;
Daniell, GJ ;
Meeson, S .
PHYSICS IN MEDICINE AND BIOLOGY, 1998, 43 (05) :1215-1224
[4]  
Delaunay B., 1934, Bull. Acad. Sci. USSR. Cl. Sci. Math, V7, P1
[5]  
FREITAG L, 1997, ASME, V220, P37
[7]   DISTINGUISHABILITY OF CONDUCTIVITIES BY ELECTRIC-CURRENT COMPUTED-TOMOGRAPHY [J].
ISAACSON, D .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 1986, 5 (02) :91-95
[8]   Comparison of algorithms for non-linear inverse 3D electrical tomography reconstruction [J].
Molinari, M ;
Cox, SJ ;
Blott, BH ;
Daniell, GJ .
PHYSIOLOGICAL MEASUREMENT, 2002, 23 (01) :95-104
[9]   Adaptive mesh refinement techniques for electrical impedance tomography [J].
Molinari, M ;
Cox, SJ ;
Blott, BH ;
Daniell, GJ .
PHYSIOLOGICAL MEASUREMENT, 2001, 22 (01) :91-96
[10]  
TANG M, 2001, 3 EPSRC ENG NETW M B, P37