Design of Current Leads for a High Voltage Superconducting Apparatus

被引:13
作者
Heo, Jeong Il [1 ]
Hong, Jonggi [1 ]
Nam, Seokho [1 ]
Choi, Seyong [2 ]
Kang, Hyoungku [1 ]
机构
[1] Korea Natl Univ Transportat, Dept Elect Engn, Chungju, South Korea
[2] Korea Basic Sci Inst, Ctr Analyt Instrumentat Dev, Pusan 609735, South Korea
基金
新加坡国家研究基金会;
关键词
Condenser-type current lead; gas insulation; high voltage superconducting apparatus; solid insulation;
D O I
10.1109/TASC.2013.2238278
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
In the Republic of Korea, it is widely thought that the subcooled liquid nitrogen cooling system is the most promising method to develop a high-voltage superconducting apparatus. This method involves injecting a gaseous insulation medium, such as He, Ne, or N-2, into the superconducting apparatus to control the system pressure [1]. Therefore, a study on the dielectric characteristics of gaseous and solid insulation materials must be conducted to design the current lead parts for a high-voltage superconducting apparatus, such as a superconducting fault current limiter, superconducting cable, and superconducting transformer with a subcooled liquid nitrogen cooling system. In this paper, a study on the electrical breakdown characteristics of gaseous insulation materials is conducted to estimate the thickness of the gaseous layer between the current lead and the metallic enclosure. An analysis on the dielectric characteristics of the GFRP ( glass fiber reinforced plastic) is performed to determine the thickness of the GFRP sheath for a current lead. It is found that the electric field intensity of the gaseous insulation media at flashover can be represented as the function of field utilization factors at various pressures: 0.1, 0.2, 0.3, and 0.4 MPa. Also, it is revealed that the electric field intensity at sparkover with an electrical breakdown of the GFRP can be represented as a constant value regardless of system pressure, and a field utilization factor under the conditions of quasi-uniform electric fields. All dielectric experiments are conducted under liquid nitrogen at a temperature of 77 K. The conceptual insulation design of condenser-type current leads for a 22.9 kV and a 154 kV superconducting apparatus is undertaken.
引用
收藏
页数:5
相关论文
共 7 条
  • [1] A study on designing the electrical insulation of condenser-type terminations for 154 kV class HTS cables
    Choi, J. W.
    Choi, J. H.
    Kim, H. J.
    Cho, J. W.
    Kim, S. H.
    [J]. PHYSICA C-SUPERCONDUCTIVITY AND ITS APPLICATIONS, 2009, 469 (15-20): : 1707 - 1711
  • [2] Breakdown mechanism of liquid nitrogen viewed from area and volume effects
    Hayakawa, N
    Sakakibara, H
    Goshima, H
    Hikita, M
    Okubo, H
    [J]. IEEE TRANSACTIONS ON DIELECTRICS AND ELECTRICAL INSULATION, 1997, 4 (01) : 127 - 134
  • [3] Analysis on the Dielectric Characteristics of Insulation Gases for Developing a High Voltage Superconducting Fault Current Limiter
    Kang, Hyoungku
    Ko, Tae Kuk
    [J]. IEEE TRANSACTIONS ON APPLIED SUPERCONDUCTIVITY, 2011, 21 (03) : 1332 - 1335
  • [4] Study on the Breakdown Voltage Characterization of Insulation Gases for Developing a High Voltage Superconducting Apparatus
    Kang, Hyoungku
    Nah, Jin Bae
    Chung, Yoon Do
    Ahn, Min Cheol
    Bae, Duck Kweon
    Ko, Tae Kuk
    [J]. IEEE TRANSACTIONS ON APPLIED SUPERCONDUCTIVITY, 2010, 20 (03) : 1646 - 1649
  • [5] Numerical Analysis and Electrical Insulation Design of a Single-Phase 154 kV Class Non-Inductively Wound Solenoid Type Superconducting Fault Current Limiter
    Na, Jin Bae
    Kang, Hyoungku
    Ko, Tae Kuk
    [J]. IEEE TRANSACTIONS ON APPLIED SUPERCONDUCTIVITY, 2012, 22 (03)
  • [6] Oh K. H., 1993, P ANN REP C EL INS D, P162
  • [7] Electrical Insulation Characteristics of Glass Fiber Reinforced Resins
    Tuncer, Enis
    Sauers, Isidor
    James, D. Randy
    Ellis, Alvin R.
    [J]. IEEE TRANSACTIONS ON APPLIED SUPERCONDUCTIVITY, 2009, 19 (03) : 2359 - 2362