Mapping motion from 4D-MRI to 3D-CT for use in 4D dose calculations: A technical feasibility study

被引:104
作者
Boye, Dirk [1 ,2 ]
Lomax, Tony [1 ,3 ]
Knopf, Antje [1 ]
机构
[1] Paul Scherrer Inst, Ctr Proton Therapy, CH-5232 Villigen, Switzerland
[2] ETH, Comp Vis Lab, CH-8092 Zurich, Switzerland
[3] ETH, CH-8092 Zurich, Switzerland
基金
瑞士国家科学基金会;
关键词
4D-MRI; 4D dose calculations; DEFORMABLE REGISTRATION; COMPUTED-TOMOGRAPHY; RESPIRATORY MOTION; TUMOR TRACKING; CT; RADIOTHERAPY; APPROXIMATION; INTERPOLATION; SEGMENTATION; STRATEGIES;
D O I
10.1118/1.4801914
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: Target sites affected by organ motion require a time resolved (4D) dose calculation. Typical 4D dose calculations use 4D-CT as a basis. Unfortunately, 4D-CT images have the disadvantage of being a "snap-shot" of the motion during acquisition and of assuming regularity of breathing. In addition, 4D-CT acquisitions involve a substantial additional dose burden to the patient making many, repeated 4D-CT acquisitions undesirable. Here the authors test the feasibility of an alternative approach to generate patient specific 4D-CT data sets. Methods: In this approach motion information is extracted from 4D-MRI. Simulated 4D-CT data sets [which the authors call 4D-CT(MRI)] are created by warping extracted deformation fields to a static 3D-CT data set. The employment of 4D-MRI sequences for this has the advantage that no assumptions on breathing regularity are made, irregularities in breathing can be studied and, if necessary, many repeat imaging studies (and consequently simulated 4D-CT data sets) can be performed on patients and/or volunteers. The accuracy of 4D-CT(MRI)s has been validated by 4D proton dose calculations. Our 4D dose algorithm takes into account displacements as well as deformations on the originating 4D-CT/4D-CT(MRI) by calculating the dose of each pencil beam based on an individual time stamp of when that pencil beam is applied. According to corresponding displacement and density-variation-maps the position and the water equivalent range of the dose grid points is adjusted at each time instance. Results: 4D dose distributions, using 4D-CT( MRI) data sets as input were compared to results based on a reference conventional 4D-CT data set capturing similar motion characteristics. Almost identical 4D dose distributions could be achieved, even though scanned proton beams are very sensitive to small differences in the patient geometry. In addition, 4D dose calculations have been performed on the same patient, but using 4D-CT(MRI) data sets based on variable breathing patterns to show the effect of possible irregular breathing on active scanned proton therapy. Using a 4D-CT(MRI), including motion irregularities, resulted in significantly different proton dose distributions. Conclusions: The authors have demonstrated that motion information from 4D-MRI can be used to generate realistic 4D-CT data sets on the basis of a single static 3D-CT data set. 4D-CT(MRI) presents a novel approach to test the robustness of treatment plans in the circumstance of patient motion. (c) 2013 American Association of Physicists in Medicine.
引用
收藏
页数:11
相关论文
共 43 条
  • [21] Four-dimensional image-based treatment planning: Target volume segmentation and dose calculation in the presence of respiratory motion
    Rietzel, E
    Chen, GTY
    Choi, NC
    Willet, CG
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2005, 61 (05): : 1535 - 1550
  • [22] Deformable registration of 4D computed tomography data
    Rietzel, Eike
    Chen, George T. Y.
    [J]. MEDICAL PHYSICS, 2006, 33 (11) : 4423 - 4430
  • [23] Ruan D., 2008, Nuclear Science Symposium Confer- ence Record 2008. NSS '08. IEEE, P5304, DOI DOI 10.1109/NSSMIC.2008.4774431
  • [24] DISCRIMINATIVE SLIDING PRESERVING REGULARIZATION IN MEDICAL IMAGE REGISTRATION
    Ruan, Dan
    Esedoglu, Selim
    Fessler, Jeffrey A.
    [J]. 2009 IEEE INTERNATIONAL SYMPOSIUM ON BIOMEDICAL IMAGING: FROM NANO TO MACRO, VOLS 1 AND 2, 2009, : 430 - 433
  • [25] Nonrigid registration using free-form deformations: Application to breast MR images
    Rueckert, D
    Sonoda, LI
    Hayes, C
    Hill, DLG
    Leach, MO
    Hawkes, DJ
    [J]. IEEE TRANSACTIONS ON MEDICAL IMAGING, 1999, 18 (08) : 712 - 721
  • [26] Simulation of four-dimensional CT images from deformable registration between inhale and exhale breath-hold CT scans
    Sarrut, D
    Boldea, V
    Miguet, S
    Ginestet, C
    [J]. MEDICAL PHYSICS, 2006, 33 (03) : 605 - 617
  • [27] Dose calculation models for proton treatment planning using a dynamic beam delivery system: an attempt to include density heterogeneity effects in the analytical dose calculation
    Schaffner, B
    Pedroni, E
    Lomax, A
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 1999, 44 (01) : 27 - 41
  • [28] Schnabel J.A., 2001, INT C MEDICAL IMAGE, P573
  • [29] Image interpolation in 4D CT using a BSpline deformable registration model
    Schreibmann, E
    Chen, GTY
    Xing, L
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2006, 64 (05): : 1537 - 1550
  • [30] 4D CT Image Simulation Using B-Spline Deformable Model and Cosine Interpolation of Deformation field
    Tian, Zhen
    Yuan, Kehong
    Bai, Yanling
    [J]. 2009 ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-20, 2009, : 3541 - 3544