Mapping motion from 4D-MRI to 3D-CT for use in 4D dose calculations: A technical feasibility study

被引:104
作者
Boye, Dirk [1 ,2 ]
Lomax, Tony [1 ,3 ]
Knopf, Antje [1 ]
机构
[1] Paul Scherrer Inst, Ctr Proton Therapy, CH-5232 Villigen, Switzerland
[2] ETH, Comp Vis Lab, CH-8092 Zurich, Switzerland
[3] ETH, CH-8092 Zurich, Switzerland
基金
瑞士国家科学基金会;
关键词
4D-MRI; 4D dose calculations; DEFORMABLE REGISTRATION; COMPUTED-TOMOGRAPHY; RESPIRATORY MOTION; TUMOR TRACKING; CT; RADIOTHERAPY; APPROXIMATION; INTERPOLATION; SEGMENTATION; STRATEGIES;
D O I
10.1118/1.4801914
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: Target sites affected by organ motion require a time resolved (4D) dose calculation. Typical 4D dose calculations use 4D-CT as a basis. Unfortunately, 4D-CT images have the disadvantage of being a "snap-shot" of the motion during acquisition and of assuming regularity of breathing. In addition, 4D-CT acquisitions involve a substantial additional dose burden to the patient making many, repeated 4D-CT acquisitions undesirable. Here the authors test the feasibility of an alternative approach to generate patient specific 4D-CT data sets. Methods: In this approach motion information is extracted from 4D-MRI. Simulated 4D-CT data sets [which the authors call 4D-CT(MRI)] are created by warping extracted deformation fields to a static 3D-CT data set. The employment of 4D-MRI sequences for this has the advantage that no assumptions on breathing regularity are made, irregularities in breathing can be studied and, if necessary, many repeat imaging studies (and consequently simulated 4D-CT data sets) can be performed on patients and/or volunteers. The accuracy of 4D-CT(MRI)s has been validated by 4D proton dose calculations. Our 4D dose algorithm takes into account displacements as well as deformations on the originating 4D-CT/4D-CT(MRI) by calculating the dose of each pencil beam based on an individual time stamp of when that pencil beam is applied. According to corresponding displacement and density-variation-maps the position and the water equivalent range of the dose grid points is adjusted at each time instance. Results: 4D dose distributions, using 4D-CT( MRI) data sets as input were compared to results based on a reference conventional 4D-CT data set capturing similar motion characteristics. Almost identical 4D dose distributions could be achieved, even though scanned proton beams are very sensitive to small differences in the patient geometry. In addition, 4D dose calculations have been performed on the same patient, but using 4D-CT(MRI) data sets based on variable breathing patterns to show the effect of possible irregular breathing on active scanned proton therapy. Using a 4D-CT(MRI), including motion irregularities, resulted in significantly different proton dose distributions. Conclusions: The authors have demonstrated that motion information from 4D-MRI can be used to generate realistic 4D-CT data sets on the basis of a single static 3D-CT data set. 4D-CT(MRI) presents a novel approach to test the robustness of treatment plans in the circumstance of patient motion. (c) 2013 American Association of Physicists in Medicine.
引用
收藏
页数:11
相关论文
共 43 条
  • [11] Treatment planning using MRI data: an analysis of the dose calculation accuracy for different treatment regions
    Jonsson, Joakim H.
    Karlsson, Magnus G.
    Karlsson, Mikael
    Nyholm, Tufve
    [J]. RADIATION ONCOLOGY, 2010, 5
  • [12] Kapanen M, 2012, MAGN RESON MED
  • [13] Scanned proton radiotherapy for mobile targets-the effectiveness of re-scanning in the context of different treatment planning approaches and for different motion characteristics
    Knopf, Antje-Christin
    Hong, Theodore S.
    Lomax, Antony
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2011, 56 (22) : 7257 - 7271
  • [14] Scattered data interpolation with multilevel B-splines
    Lee, S
    Wolberg, G
    Shin, SY
    [J]. IEEE TRANSACTIONS ON VISUALIZATION AND COMPUTER GRAPHICS, 1997, 3 (03) : 228 - 244
  • [15] New algorithm to simulate organ movement and deformation for four-dimensional dose calculation based on a three-dimensional CT and fluoroscopy of the thorax
    Miyabe, Yuki
    Narita, Yuichiro
    Mizowaki, Takashi
    Matsuo, Yukinori
    Takayama, Kenji
    Takahashi, Kunio
    Kaneko, Shuji
    Kawada, Noriyuki
    Maruhashi, Akira
    Hiraoka, Masahiro
    [J]. MEDICAL PHYSICS, 2009, 36 (10) : 4328 - 4339
  • [16] Four dimensional CT imaging: a review of current technologies and modalities
    Moorrees, J.
    Bezak, E.
    [J]. AUSTRALASIAN PHYSICAL & ENGINEERING SCIENCES IN MEDICINE, 2012, 35 (01) : 9 - 23
  • [17] 4D-CT imaging of a volume influenced by respiratory motion on multi-slice CT
    Pan, T
    Lee, TY
    Rietzel, E
    Chen, GTY
    [J]. MEDICAL PHYSICS, 2004, 31 (02) : 333 - 340
  • [18] Deviations in delineated GTV caused by artefacts in 4DCT
    Persson, Gitte Fredberg
    Nyaard, Ditte Eklund
    Brink, Carsten
    Jahn, Jonas Westberg
    af Rosenschold, Per Munck
    Specht, Lena
    Korreman, Stine Sofia
    [J]. RADIOTHERAPY AND ONCOLOGY, 2010, 96 (01) : 61 - 66
  • [19] EFFECTS OF RESPIRATORY MOTION ON DOSE UNIFORMITY WITH A CHARGED-PARTICLE SCANNING METHOD
    PHILLIPS, MH
    PEDRONI, E
    BLATTMANN, H
    BOEHRINGER, T
    CORAY, A
    SCHEIB, S
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 1992, 37 (01) : 223 - 234
  • [20] Preiswerk Frank, 2012, Abdominal Imaging. Computational and Clinical Applications. Third International Workshop Held in Conjunction with MICCAI 2011. Revised Selected Papers, P207, DOI 10.1007/978-3-642-28557-8_26